Machine learning in diagnosing coronary artery disease via optical pumped magnetometer magnetocardiography: a prospective cohort study
Open accessThe DOI matches its Crossref record; 32 of the 34 references it cites were found in a registry or an index.
Abstract
Objective. The potential of optical pumped magnetometer magnetocardiography (OPM-MCG) for diagnosing coronary artery disease (CAD) has been initially shown, yet lacks large-scale prospective research. Approach. Using invasive coronary angiography (ICA) as a reference, we constructed three feature sets for the development of machine learning (ML) models: a ‘Heart’ feature set consisting only of OPM-MCG features, a ‘Clinical’ feature set, and a ‘Heart + Clinical’ combined feature set. We assessed the performance of 11 ML models with 10-fold cross-validation and conducted a feature importance analysis. Main results and Significance. Among 1513 participants (mean age 58.2 ± 12.0 years, 75.5% male), 1194 (78.92%) tested positive for ICA. Significant differences were observed in ‘Heart’ and ‘Clinical’ features between ICA-positive and negative groups. ML models using only ‘Heart’ features (AUC 0.84–0.88) outperformed those using only ‘Clinical’ features (AUC 0.62–0.75). Combining both feature types improved diagnostic accuracy (AUC 0.75–0.90). Feature importance analysis highlighted that ‘Significant change of Ar-PN’ in OPM-MCG was key for ICA diagnosis (47.8%), along with ‘Abnormal Sp-TT’, ‘Significant change of Ps-PN’, and ‘Abnormal Mg-TT’. OPM-MCG has high performance in diagnosing CAD, and the significant change of Ar-PN is the most important feature. Cat Boost and random forest are more suitable for OPM-MCG to build ML diagnostic models for CAD.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tu et al. [76] demonstrate that classical ensemble methods applied to OPM-MCG-derived repolarization and morphological features can yield strong diagnostic performance, particularly when combined with clinical variables.”
In the citing paper
“Despite these advances [75,76,77], common structural constraints persist, including limited external validation, modest dataset scale, absence of calibration analyses, and restricted prospective outcome-based evaluation.”
Citations
Cites
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Martin, S. S., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Barone Gibbs, B., Beaton, A. Z., Boehme, A. K., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001209 · Cited by 2,800
Angiographic Versus Functional Severity of Coronary Artery Stenoses in the FAME Study
Tonino, P. A. L., Fearon, W. F., De Bruyne, B., Oldroyd, K. G., Leesar, M. A., Ver Lee, P. N., MacCarthy, P. A., van't Veer, M., & Pijls, N. H. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.096 · Cited by 1,271
Gheorghe, A., Griffiths, U., Murphy, A., Legido-Quigley, H., Lamptey, P., & Perel, P. (2018) · BMC Public Health · doi:10.1186/s12889-018-5806-x · Cited by 532 · cited 1×
“In addition, the financial burden of CAD on healthcare systems is high and continues to rise in both developed and developing countries (Gheorghe et al 2018, Luengo-Fernandez et al 2023).”
Narula, J., Chandrashekhar, Y., Ahmadi, A., Abbara, S., Berman, D. S., Blankstein, R., Leipsic, J., Newby, D., Nicol, E. D., Nieman, K., et al. (2021) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.11.001 · Cited by 398 · cited 1×
“This has resulted in a substantial number of nonessential ICA tests, as these patients were subsequently determined to have no significant stenosis in their coronary arteries (Tonino et al 2010, Narula et al 2021).”
Economic burden of cardiovascular diseases in the European Union: a population-based cost study
Luengo-Fernandez, R., Walli-Attaei, M., Gray, A., Torbica, A., Maggioni, A. P., Huculeci, R., Bairami, F., Aboyans, V., Timmis, A. D., Vardas, P., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad583 · Cited by 317
Recent Advances in Treatment of Coronary Artery Disease: Role of Science and Technology
Kandaswamy, E., & Zuo, L. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19020424 · Cited by 180 · cited 1×
“Characterized by the narrowing or obstruction of coronary arteries from atherosclerotic lesions, CAD can lead to serious cardiovascular events such as myocardial ischemia, infarction, and heart failure, posing significant threats to patient health and survival (Kandaswamy and Zuo 2018).”
Tao, R., Zhang, S., Huang, X., Tao, M., Ma, J., Ma, S., Zhang, C., Zhang, T., Tang, F., Lu, J., et al. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877649 · Cited by 147 · cited 2×
“OPM-MCG can be operated at ambient temperature at a low cost (Tao et al 2019, Pena et al 2020).”
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109 · cited 1×
“However, it lacks large-scale clinical studies, and the key parameters for its diagnosis of CAD are unclear (Park et al 2005, Her and Park 2016).”
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78 · cited 1×
“Compared with ECG, OPM-MCG is more sensitive to tangential currents, which are more prominent in myocardial ischemia, and its 36-channel design significantly improves spatial resolution (Tolstrup et al 2006, Camm et al 2019).”
Pezel, T., Toupin, S., Bousson, V., Hamzi, K., Hovasse, T., Lefèvre, T., Chevalier, B., Unterseeh, T., Sanguineti, F., Champagne, S., et al. (2025) · Radiology · doi:10.1148/radiol.233030 · Cited by 61
Suppression of Light Shift for High-Density Alkali-Metal Atomic Magnetometer
Lu, J., Quan, W., Ding, M., Qi, L., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877771 · Cited by 42
Self-citationClinical utility of magnetocardiography in cardiology for the detection of myocardial ischemia
Camm, A. J., Henderson, R., Brisinda, D., Body, R., Charles, R. G., Varcoe, B., & Fenici, R. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.07.009 · Cited by 42 · cited 1×
“Compared with ECG, OPM-MCG is more sensitive to tangential currents, which are more prominent in myocardial ischemia, and its 36-channel design significantly improves spatial resolution (Tolstrup et al 2006, Camm et al 2019).”
Brendel, J. M., Walterspiel, J., Hagen, F., Kübler, J., Brendlin, A., Afat, S., Paul, J., Küstner, T., Nikolaou, K., Gawaz, M., et al. (2024) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2024.09.012 · Cited by 38
Mace, S. E., Peacock, W. F., Stopyra, J. P., Mahler, S. A., Pearson, C., Pena, M. E., & Clark, C. L. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100372 · Cited by 31 · cited 2×
“Small clinical studies have also preliminarily confirmed the diagnostic value of resting OPM-MCG for CAD (Xu et al 2023, Mace et al 2024).”
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29 · cited 1×
“T segment, which is from one-third of the peak intensity (T-onset) to the peak intensity (T-peak) (Park et al 2015, Ashokprabhu et al 2024).”
The new role of diagnostic angiography in coronary physiological assessment
Ghobrial, M. S. A., Haley, H. A., Gosling, R. C., Rammohan, V., Lawford, P. V., Hose, D. R., Gunn, J. P., & Morris, P. (2021) · Heart · doi:10.1136/heartjnl-2020-318289 · Cited by 29 · cited 1×
“ICA is the current ‘gold standard’ for diagnosing CAD (Ghobrial et al 2021).”
El-Ibrahimi, A., Daanouni, O., Alouani, Z., Gannour, O. E., Saleh, S., Cherradi, B., & Bouattane, O. (2025) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2025.100208 · Cited by 23
Yang, S., Feng, L., Zhang, M., Zhang, M., Ma, Z., Zhang, H., Zhang, Y., Liu, L., Zhou, S., Zhao, X., et al. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-086433 · Cited by 21
Self-citationChaikovsky, I., Hailer, B., Sosnytskyy, V., Lutay, M., Mjasnikov, G., Kazmirchuk, A., Bydnyk, M., Lomakovskyy, A., & Sosnytskaja, T. (2014) · Coronary Artery Disease · doi:10.1097/mca.0000000000000107 · Cited by 19 · cited 1×
“During myocardial ischemia, action potential conduction in the ischemic region is weakened, resulting in pathologically heterogeneous repolarization of the region and its margins and the formation of local damage currents (Chaikovsky et al 2014).”
Her, A., & Park, J. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1305 · Cited by 18 · cited 2×
“However, it lacks large-scale clinical studies, and the key parameters for its diagnosis of CAD are unclear (Park et al 2005, Her and Park 2016).”
Diagnostic Value of Magnetocardiography to Detect Abnormal Myocardial Perfusion: A Pilot Study
Zhang, H., Ma, Z., Mi, H., Jiao, J., Dong, W., Yang, S., Liu, L., Zhou, S., Feng, L., Zhao, X., et al. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2510379 · Cited by 18
Self-citationSenthilnathan, S., Devi, S. S., Sasikala, M., Satheesh, S., & Selvaraj, R. J. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad40b1 · Cited by 17 · cited 1×
“The accuracy of SQUID-MCG in the diagnosis of CAD has been demonstrated in small populations, and the application of ML has improved its diagnostic performance (Lu et al 2019, Tao et al 2019, Senthilnathan et al 2024).”
A finite element model of needle electrode spatial sensitivity
Høyum, P., Kalvøy, H., Martinsen, Ø. G., & Grimnes, S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/10/006 · Cited by 15
Novel CAD Diagnosis Method Based on Search, PCA, and AdaBoostM1 Techniques
Eyüpoğlu, C., & Karakuş, O. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13102868 · Cited by 15 · cited 1×
“Several previous studies have applied ML methods to clinical features, demonstrating the diagnostic efficacy of clinical risk factors for CAD (Eyupoglu and Karakus¸ 2024, El-Ibrahimi et al 2025).”
Ramesh, R., Senthilnathan, S., Satheesh, S., Swain, P. P., Patel, R., Pillai, A. A., Katholil, G., & Selvaraj, R. J. (2019) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12715 · Cited by 14
Ashokprabhu, N. D., Ziada, K. M., Daher, E., Cho, L., Schmidt, C. W., Alvarez, Y. R., Palmer, C., Kaur, S., Henry, T. D., Pepine, C. J., et al. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100424 · Cited by 14 · cited 1×
“T segment, which is from one-third of the peak intensity (T-onset) to the peak intensity (T-peak) (Park et al 2015, Ashokprabhu et al 2024).”
Tao, R., Zhang, S., Zhang, R., Shen, C., Ma, J., Cui, J., Chen, Y., Wang, B., Li, H., Xie, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90615-x · Cited by 14 · cited 1×
“For example, the proportion of men with suspected CAD in magnetocardiography studies was 70% (Her and Park 2016, Tao et al 2025).”
Wu, T., Zhao, X., Feng, L., Yang, S., Xing, H., Ma, Z., Yang, X., Zhang, M., Ding, M. L., He, Y., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11389-4 · Cited by 12
Self-citationAlahdab, F., Saad, M. B., Ahmed, A. I., Al-Tashi, Q., Aminu, M., Han, Y., Moody, J. B., Murthy, V. L., Wu, J., & Al-Mallah, M. H. (2024) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101746 · Cited by 10 · cited 1×
“For example, ML has been shown to accurately predict myocardial flow reserve based on ECG data (Alahdab et al 2024), while in CCTA, AI-based quantitative assessment can achieve up to 94% diagnostic sensitivity and 82% specificity (Pezel et al 2025).”
Rácz, G. A., Kormányos, Á., Domsik, P., Kalapos, A., Gyenes, N., Havasi, K., Ambrus, N., Hartyánszky, I. L., Bogáts, G., & Nemes, A. (2021) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-366 · Cited by 8
Research works printed but not linked: 2
- Pena, 2020, A 90-second magnetocardiogram using a novel analysis system to assess for coronary artery stenosis in Emergency department observation unit chest pain patients, Int. J. Cardiol. Heart Vasculature, 26, 10.1016/j.ijcha.2020.100466 · doi:10.1016/j.ijcha.2020.100466
- Xu, 2023, Clinical value of helium-free magnetocardiography in diagnosis of coronary heart disease, Chin. J. Gen. Pract., 22, 1159
Cited by
An Integrated 64-Channel Optical-Fiber-Split OPM-MCG System
Lin, S., Ma, Y., Yuan, Z., Wang, Y., Zhai, Y., & Tang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3701180 · Cited by 2
“More recently, OPM-MCG has entered practical applications, including the detection of coronary artery diseases [29], [30], the diagnosis of fulminant myocarditis [31], and a large number of records and diagnoses of fetal MCG [32], [33], [34].”
Palantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
“Tu et al. [76] demonstrate that classical ensemble methods applied to OPM-MCG-derived repolarization and morphological features can yield strong diagnostic performance, particularly when combined with clinical variables.”
Qi, Y., Liang, J., Zhang, Y., Yang, J., Cao, F., Zhang, X., Li, H., Cui, X., Zhang, H., & Xiang, M. (2026) · Clinical Cardiology · doi:10.1002/clc.70277 · Cited by 1
“Given these advantages, SERF‐OPM MCG technology is being actively investigated by numerous clinical centers worldwide [18, 19], representing a promising frontier in noninvasive cardiovascular detection.”
Self-citationAn, Z., Wang, S., Zhang, M., Zhang, M., Xu, F., Feng, L., Ma, Z., Zhang, H., Yang, S., Tu, C., et al. (2026) · Cardiology Research and Practice · doi:10.1155/crp/9497660 · Cited by 1
Self-citationMeta-analysis of magnetocardiography in diagnosing coronary artery disease and myocardial ischemia
Li, J., Yan, M., Xiang, M., & Ning, X. (2026) · Next research. · doi:10.1016/j.nexres.2026.101496 · Cited by 1
Metadata
- Authors
- Tu, C., Yang, S., Wang, Z., Liu, L., Ma, Z., Zhang, H., Feng, L., Cai, B., Zhang, H., Ding, M., & Song, X.
- Affiliations
- Capital Medical University (CN)
- Beihang University (CN)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2025-08-11
- Volume
- 46
- Issue
- 8
- Pages
- 085003
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W4412488397
- Cited by
- 8
- References
- 34
- Citations by year
- 2026: 8
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Physiological Measurement (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- The Beijing Lab for Cardiovascular Precision Medicine (PXM2018_014226_000013)
- Beijing Hospitals Authority‘sailing’ Program (YGLX202323)
- High-level public health technical talent construction project of Beijing Municipal Health Commission (Leading Talent-02-01)
- Beijing Hospitals Authority’s Ascent Plan (DFL20220603)
- Coordinated innovation of scientific and technological in Beijing-Tianjin-Hebei Region (Z231100003923008)
- Beijing Nova Program (20220484222)
- Capital’s Funds for Health Improvement and Research (2024-2-2066)
- Topics
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- coronary artery disease, magnetocardiography, machine learning diagnosis, invasive coronary angiography, feature importance, CatBoost, random forest, noninvasive cardiac assessment
- MeSH terms
- Machine Learning, Aged, Coronary Artery Disease, Female, Humans, Male, Middle Aged, Prospective Studies, Magnetocardiography, Optical Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.