The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Non-Invasive Resting Magnetocardiographic Imaging for the Rapid Detection of Ischemia in Subjects Presenting with Chest Pain
Abstract
BACKGROUND: Early diagnosis of ischemia is complicated by the poor sensitivity of standard tests and contraindication for stress testing in unstable angina patients. Magnetocardiography (MCG) imaging can be used for the rapid, non-invasive detection of ischemia at rest. METHODS: We studied 125 patients with presumed ischemic chest pain. All were chest pain free at the time of scanning. A 6-minute resting MCG scan (CardioMag Imaging, Inc., New York, 9-channel system) was performed. Following the MCG scan, automated software data analysis was performed, and quantitative scores were automatically calculated for each subject. The presence of ischemia was determined after testing with serial troponins, stress testing, and/or coronary angiography. RESULTS: The mean age was 59.4 +/- 13.6 years. Most patients (86.4%) had non-ischemic 12-lead ECG and normal troponin (86.2%). Fifty-five patients (44.0%) were determined to be ischemic. The MCG sensitivity, specificity, positive and negative predictive value was 76.4, 74.3, 70.0 and 80.0%, respectively, for the detection of ischemia (p < 0.0001). CONCLUSIONS: MCG is a new rapid, non-invasive imaging tool able to detect repolarization abnormalities at rest consistent with ischemia in patients presenting with chest pain syndrome and normal or non-specific 12-lead ECG and normal troponin.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74 · cited 1×
“], or on lipid reduction therapy), family history of early coronary artery disease, and history of previous myocardial infarction. Data Interpretation The ECG’s were interpreted by the research teams at the three institutions and categorized into ischemic or non-ischemic according to standard criteria as follows: Isch…”
MethodHänninen, H., Takala, P., Korhonen, P., Oikarinen, L., Mäkijärvi, M., Nenonen, J., Katila, T., & Toivonen, L. (2002) · Annals of Medicine · doi:10.1080/07853890252953518 · Cited by 49 · cited 1×
“], or on lipid reduction therapy), family history of early coronary artery disease, and history of previous myocardial infarction. Data Interpretation The ECG’s were interpreted by the research teams at the three institutions and categorized into ischemic or non-ischemic according to standard criteria as follows: Isch…”
MethodKorhonen, P., MOINTONEN, J., MÄKINÄRVI, M., Katila, T. E., Nieminen, M. S., & Toivonen, L. K. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00336.x · Cited by 43
Magnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42 · cited 1×
“However, all these studies were performed on early generation MCG machines, which required a magnetically shielded room to obtain images with an acceptable signal-to-noise ratio. In addition, none of those studies utilized an automated software program or standardized method for the analysis of the acquired data. Rece…”
MethodAnalysis of current source of the heart using Isomagnetic and Vector arrow maps.
Nakaya, Y., Sumi, M., Saito, K., Fujino, K., Murakami, M., & Mori, H. (1984) · Japanese Heart Journal · doi:10.1536/ihj.25.701 · Cited by 35
Leeuwen, P. V., Hailer, B., Lange, S., Donker, D. W., & Grönemeyer, D. H. W. (1999) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1999.44.s2.139 · Cited by 26
Comparative capabilities of electrocardiography and magnetocardiography
Plonsey, R. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90179-8 · Cited by 24
Cited by
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
“Tolstrup and colleagues used a different method called effective magnetic dipole vector analysis, an automated analysis of the electrical activity during repolarization, and reported statistically significant differences between the ischemic (n=55) and non-ischemic (n=70) groups [46].”
MethodSelf-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Pena, M. E., Pearson, C., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 78
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57
“Machine learning is a promising technique that explores previously unknown regularities and trends from diverse data sets by learning from sets of data and extrapolating the new-found knowledge on testing data [16–18].”
BackgroundBrala, D., Thevathasan, T., Grahl, S., Barrow, S., Violano, M., Bergs, H., Golpour, A., Suwalski, P., Poller, W., Skurk, C., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.027619 · Cited by 54
Metadata
- Authors
- Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A.
- Affiliations
- Cedars-Sinai Medical Center (US)
- Mayo Clinic (US)
- Lausitzer Seenland Klinikum (DE)
- Venue
- Cardiology
- Publisher
- S. Karger AG
- Published
- 2006
- Volume
- 106
- Issue
- 4
- Pages
- 270-276
- ISSN
- 0008-6312 (ISSN-L)
- 1421-9751
- OpenAlex
- W1999463028
- Cited by
- 78
- References
- 14
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 7 · 2023: 4 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 2
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.karger.com/Services/SiteLicenses (vor)
- www.karger.com/Services/SiteLicenses (tdm)
- Locations
- Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- magnetocardiography, myocardial ischemia detection, chest pain, unstable angina, repolarization abnormalities, noninvasive cardiac imaging, diagnostic accuracy, troponin, stress testing
- MeSH terms
- Adult, Aged, Aged, 80 and over, Angina, Unstable, Chest Pain, Electrocardiography, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Rest, Sensitivity and Specificity, Time Factors, Troponin, Myocardial Ischemia, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-Invasive Resting Magnetocardiographic Imaging for the Rapid Detection of Ischemia in Subjects Presenting with Chest Pain. https://app.cochat.ai/papers/10.1159/000093490
- The paper
- Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006). Non-Invasive Resting Magnetocardiographic Imaging for the Rapid Detection of Ischemia in Subjects Presenting with Chest Pain. Cardiology. https://doi.org/10.1159/000093490
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.