Atomic clocks for geodesy
Open accessThe DOI matches its Crossref record; 401 of the 406 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10 −17 , opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein’s general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today’s best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10 −18 , comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Generally, the observed frequencies are in fl uenced by environmental factors, such as temperature changes, supply voltages, magnetic fi eld, barometric pressure, humidity, hydrology loading, stress, vibration, acceleration, etc.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al. (2018)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These error items mainly depend on the design and manufacture of the optical clock, which should be evaluated before practical application [39].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [39]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, it is necessary to emphasize that optical atomic clocks applications in geodesy depend on the size (i.e., transportability), price, and link technology which are very important for future developments, as discussed in the review paper by Mehlstäubler et al. (2018).”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al. (2018)
The cited source says what the claim attributes to it.
In the citing paper
“The redshift is related to the gravitational potential difference where a fractional frequency shift of 10 -18 corresponds to a height difference of 1 cm at or near the Earth ' s surface (Mehlstäubler et al., 2018).”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al., 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 401–402 of 402
Prospect for bad cavity laser on large ion crystalPreprint
Kazakov, G. A., Bohnet, J., & Schumm, T. (2017) · arXiv (Cornell University) · Cited by 3
Vaníček, P. (2003) · Elsevier eBooks · doi:10.1016/b0-12-227410-5/00283-0 · Cited by 1
Research works printed but not linked: 9
- Denker, H. (1998) Evaluation and improvement of the EGG97 quasigeoid model for Europe by GPS and leveling data. In: Vermeer, M., Ádám, J. (eds.), Second Continental Workshop on the Geoid in Europe, Proceed., Rep. Finnish Geod. Inst. 98:4: 53-61, Masala · DOI
- Dick, G.J., 1987. Local Oscillator Induced Instabilities in Trapped Ion Frequency Standards, in: Proc. 19th Annual Precise Time and Time Interval (PTTI) Application and Planning Meeting. pp. 133-147.
- Drewes H 2007 Science rational of the Global Geodetic Observation System (CGOS) in Internat. Ass. of Geodesy Symposia (Springer) vol 130 p.703
- Dubé P, Madej AA, Zhou Z, Bernard JE 2013 Evaluation of systematic shifts of the 88 Sr + single-ion optical frequency standard at the 10 -17 level. Physical Review A 87 023806
- Ghosh, P.K., 1995. Ion traps. Clarendon press.
- Herring, T. (2009) Overview. In: G. Schubert, T. Herring (eds.), Treatise on Geophysics, Vol. 3, Geodesy, 1-10, Elsevier, Amsterdam
- Rosenband, T., Itano, W.M., Schmidt, P.O., Hume, D.B., Koelemeij, J.C.J., Bergquist, J.C., Wineland, D.J., 2006. Blackbody radiation shift of the 27 Al + 1 S0 3 P0 transition, in: Proceedings of the 20th European Frequency and Time Forum. Presented at the EFTF, Braunschweig, Germany, pp. 289-291.
- Scheibe A., Adelsberger U. 1936 Nachweis von Schwankungen der astronomischen Tageslänge im Jahre 1935 mittels Quarzuhren Phys. Zeitschrift 37 38
- Strang van Hees, G.L. (1977) Zur zeitlichen Änderung von Schwere und Höhe. Zeitschrift für Vermessungswesen, 10, 444-450
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Micius quantum experiments in space
Lu, C.-Y., Cao, Y., Peng, C.-Z., & Pan, J.-W. (2022) · Reviews of Modern Physics · doi:10.1103/revmodphys.94.035001 · Cited by 295
Energy of the 229Th nuclear clock transition
Seiferle, B., von der Wense, L., Bilous, P. V., Amersdorffer, I., Lemell, C., Libisch, F., Stellmer, S., Schumm, T., Düllmann, C. E., Pálffy, A., et al. (2019) · Nature · doi:10.1038/s41586-019-1533-4 · Cited by 230
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 208
“…as well as improved time synchronization for high-resolution telescope arrays and future VLBI Relativistic geodesy/alternative theories of gravitation generations [16], geopotential monitoring with centimetre resolution [17], quantum networks for quantum encrypted communications [18], and others.”
Background
Metadata
- Authors
- Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- Corresponding author
- Mehlstäubler, Tanja E
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2018-04-18
- Volume
- 81
- Issue
- 6
- Pages
- 064401
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2791228270
- Cited by
- 263
- References
- 406
- Citations by year
- 2026: 22 · 2025: 39 · 2024: 45 · 2023: 36 · 2022: 33 · 2021: 26 · 2020: 34 · 2019: 24 · 2018: 4
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Reports on Progress in Physics (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- optical atomic clocks, frequency transfer, geodesy, height reference system, clock comparison, tests of general relativity, portable atomic clock
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.