Atomic clocks for geodesy
Open accessThe DOI matches its Crossref record; 401 of the 406 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10 −17 , opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein’s general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today’s best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10 −18 , comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Generally, the observed frequencies are in fl uenced by environmental factors, such as temperature changes, supply voltages, magnetic fi eld, barometric pressure, humidity, hydrology loading, stress, vibration, acceleration, etc.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al. (2018)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These error items mainly depend on the design and manufacture of the optical clock, which should be evaluated before practical application [39].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [39]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, it is necessary to emphasize that optical atomic clocks applications in geodesy depend on the size (i.e., transportability), price, and link technology which are very important for future developments, as discussed in the review paper by Mehlstäubler et al. (2018).”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al. (2018)
The cited source says what the claim attributes to it.
In the citing paper
“The redshift is related to the gravitational potential difference where a fractional frequency shift of 10 -18 corresponds to a height difference of 1 cm at or near the Earth ' s surface (Mehlstäubler et al., 2018).”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Mehlstäubler et al., 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The cosmological constant and dark energy
Peebles, P. J. E., & Ratra, B. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.559 · Cited by 5,213 · cited 1×
“In the search for unifying theories and the puzzle of Dark Energy and Dark Matter (Peebles 2003), several alternative theories of gravitation predict violations of the EEP.”
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996 · cited 2×
“The validity of classical GR is frequently questioned and some models of quantum gravity suggest that Lorentz invariance may be violated at the energy scales relevant for our experiments (Will 2014).”
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692 · cited 2×
“For white frequency noise, the statistical uncertainty, uA, is equivalent to the Allan deviation σy(τ) (Allan, 1966; Riehle, 2004; Riley, 2008).”
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661 · cited 2×
“The frequency of the m th comb tooth (when counting from zero) is given by the comb equation f m = mf r + f CEO (Telle et al 1999, Udem et al 1999, Jones et al 2000).”
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationEncyclopedia of physical science and technology
(2002) · Choice Reviews Online · doi:10.5860/choice.39-3718 · Cited by 2,087
Electromagnetic traps for charged and neutral particles
Paul, W. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.531 · Cited by 1,561
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497 · cited 1×
“In a linear Paul trap (Wineland et al., 1998) radial confinement is provided by an oscillating 2D rf quadrupole electric field, while axial trapping is achieved by applying an additional 3D dc quadrupole (see figure 5.”
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 4×
“Within laboratories or over short distances, fibre links can be established very easily, using similar (but usually simplified) techniques (Rosenband et al 2008) to those presented in this chapter.”
InfluentialSelf-citationNobel Lecture: Laser cooling and trapping of neutral atoms
Phillips, W. D. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.721 · Cited by 1,443 · cited 1×
“A close approximation of this ideal situation has been achieved through the development of laser cooling techniques (Chu 1998, Cohen-Tannoudji 1998, Phillips 1998) and by trapping the atoms either in an optical lattice (Katori et al 2003) or in an ion trap (Bergquist et al 1987) under ultra-high…”
Altamimi, Z., Rebischung, P., Métivier, L., & Collilieux, X. (2016) · Journal of Geophysical Research: Solid Earth · doi:10.1002/2016jb013098 · Cited by 1,427 · cited 3×
“The most recent realization of the ITRS is the ITRF2014, with GNSS being a major contributor (Altamimi et al. 2016).”
ITRF2008: an improved solution of the international terrestrial reference frame
Altamimi, Z., Collilieux, X., & Métivier, L. (2011) · Journal of Geodesy · doi:10.1007/s00190-011-0444-4 · Cited by 1,181
Dewdney, P. E., Hall, P. J., Schilizzi, R. T., & Lazio, T. J. L. W. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2021005 · Cited by 1,164
(2014) · Dictionary Geotechnical Engineering/Wörterbuch GeoTechnik · doi:10.1007/978-3-642-41714-6_10674 · Cited by 1,137
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 5×
“Other validations (Bloom et al 2014, Lisdat et al 2016) of Sr lattice clocks reach mid-10 − 17 uncertainties.”
InfluentialNobel Lecture: The manipulation of neutral particles
Chu, S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.685 · Cited by 919 · cited 1×
“A close approximation of this ideal situation has been achieved through the development of laser cooling techniques (Chu 1998, Cohen-Tannoudji 1998, Phillips 1998) and by trapping the atoms either in an optical lattice (Katori et al 2003) or in an ion trap (Bergquist et al 1987) under ultra-high…”
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903 · cited 6×
“…to resolve height differences of tens of cm in the gravitational field on Earth ’ s surface was demonstrated first in 2010, where two Al + quant um logic clocks were compared against each other while elevating one of them on an optical table to a height difference of 30 cm (Chou et al 2010b).”
InfluentialTelle, H. R., Steinmeyer, G., Dunlop, A. E., Stenger, J., Sutter, D. H., & Keller, U. (1999) · Applied Physics B · doi:10.1007/s003400050813 · Cited by 871 · cited 5×
“Through stabilization of f CEO to f r , a phase-locked gear box between the frequency standard and the two radio frequencies is established, thus realizing an optical clock with a frequency of (4.6) This relation enables an absolute frequency measurement of the optical frequency by counting the frequencies f r and f C…”
InfluentialNobel Lecture: Manipulating atoms with photons
Cohen-Tannoudji, C. N. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.707 · Cited by 831 · cited 2×
“A close approximation of this ideal situation has been achieved through the development of laser cooling techniques (Chu, 1998; Cohen-Tannoudji, 1998; Phillips, 1998) and by trapping the atoms either in an optical lattice (Katori et al.”
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“…as discussed in section 4, the duty cycle of the interrogation in the clock cycles has improved and the influence of the Dick effect has been reduced such that clock instabilities of few 10 − 16 / √ τ /s have been demonstrated (Hinkley et al 2013, Al-Masoudi et al 2015, Nicholson et al 2015).”
Pound, R. V., & Rebka, G. A. (1960) · Physical Review Letters · doi:10.1103/physrevlett.4.337 · Cited by 804
Absolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791 · cited 2×
“The frequency of the m th comb tooth (when counting from zero) is given by the comb equation f m = mf r + f CEO (Telle et al 1999, Udem et al 1999, Jones et al 2000).”
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 9×
“These are typically group-II like atoms; most often Sr (Nicholson et al. 2015; Tanabe et al. 2015; Lin et al. 2015; Lodewyck et al. 2016; Grebing et al. 2016; Takano et al. 2016; Hachisu et al. 2017), Yb (Takamoto et al.”
InfluentialA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754 · cited 1×
“These now significantly outperform systems in the visible (Kessler et al. 2012) (see section 4.”
Geodetic Reference System 1980
Moritz, H. (1992) · Bulletin G�od�sique · doi:10.1007/bf00989270 · Cited by 740 · cited 3×
“ITRF station coordinates are primarily given as Cartesian coordinates, but can also be transformed into ellipsoidal coordinates (ellipsoidal latitude, longitude, and height) based on a given reference ellipsoid (such as the Geodetic Reference System 1980, GRS80; Moritz 2000); Cartesian and ellipsoidal coordinates are…”
Resolved-Sideband Raman Cooling of a Bound Atom to the 3D Zero-Point Energy
Monroe, C., Meekhof, D. M., King, B. E., Jefferts, S. R., Itano, W. M., Wineland, D. J., & Gould, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4011 · Cited by 731 · cited 1×
“Assuming a thermal motional state, the mean kinetic energy can be probed via sideband spectroscopy within seconds (Monroe et al 1995, Ludlow et al 2015), and without the need to observe the clock frequency shift as a function of residual thermal energy of the atoms.”
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720 · cited 3×
“Stray electric fields or asymmetries in the rf field can cause excess micromotion, which can be compensated to reduce Doppler-induced frequency shifts (Berkeland et al. 1998; Keller et al., 2015).”
Trapped nonneutral plasmas, liquids, and crystals (the thermal equilibrium states)
Dubin, D. H. E., & O’Neil, T. M. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.87 · Cited by 717
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 2×
“…the clock interrogation increases the uncertainty of these shifts which together with the evaluation of the BBR environment and the knowledge about the differential polarizability, are the major contributors to the clock inaccuracy (Dole ž al et al 2015, Huntemann et al 2016 (Godun et al 2014).”
InfluentialSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643 · cited 1×
“Therefore, a co-trapped well-controllable logic ion (such as Be + , Mg + or Ca + ) takes on these tasks using a technique called quantum logic spectroscopy (Schmidt et al 2005).”
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 5×
“2014) as well as for cryogenic environments (Ushijima et al. 2015).”
InfluentialThe evolving optical frequency comb [Invited]
Diddams, S. A. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.000b51 · Cited by 615 · cited 1×
“The invention of stabilized optical combs was instrumental in the advance of optical frequency metrology and optical clocks (Hall 2006, H ä nsch 2006, Diddams 2010).”
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614 · cited 1×
“The invention of stabilized optical combs was instrumental in the advance of optical frequency metrology and optical clocks (Hall 2006, H ä nsch 2006, Diddams 2010).”
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613 · cited 2×
“The discreteness of the measurement results in so-called quantum projection noise (QPN) and is given by δ S = Np ( 1 − p ) (Itano et al 1993), where N is the number of atoms and p is the excitation probability ( p ≈ 0.5 in our scenario). the The observed linewidth scales with inverse of the probe…”
InfluentialVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605 · cited 1×
“mal noise can be reduced by using long cavities made from titanium-doped glass (e.g. ULETM) and fused silica mirrors (Amairi et al., 2013; Keller et al.,2013; Häfner et al., 2015; Jiang et al., 2011; Young et al., 1999). This way, an instability below 10−16 from 1 to 1000 s has been achieved et al., 2015). By choosing…”
Handbook of frequency stability analysis
Riley, W. J., & Riley, W. J. (2008) · doi:10.6028/nist.sp.1065 · Cited by 586 · cited 5×
“Beyond this, optical clock networks and corresponding link technologies are currently established or are under discussion, from which distinct advantages are expected for the dissemination of time, geodesy, astronomy and basic research; for a review see Riehle (2017).”
Influential1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572 · cited 2×
“A close approximation of this ideal situation has been achieved through the development of laser cooling techniques (Chu, 1998; Cohen-Tannoudji, 1998; Phillips, 1998) and by trapping the atoms either in an optical lattice (Katori et al., 2003) or in an ion trap (Bergquist et al.”
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560 · cited 2×
“…in this regime that were necessary for high precision spectroscopic application such as the determination of the hydrogen 1S – 2S two-photon transition frequency (Niering et al 2000, Fischer et al 2004, Parthey et al 2011) or the 40 Ca + clock transition frequency (Chwalla et al 2009).”
Laser cooling and trapping of neutral atoms
Adams, C. S., & Riis, E. (1997) · Progress in Quantum Electronics · doi:10.1016/s0079-6727(96)00006-7 · Cited by 557
Thermal-Noise Limit in the Frequency Stabilization of Lasers with Rigid Cavities
Numata, K., Kemery, A., & Camp, J. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.250602 · Cited by 554
Heating of trapped ions from the quantum ground state
Turchette, Q. A., Kielpinski, King, B. E., Leibfried, D., Meekhof, D. M., Myatt, C. J., Rowe, M. A., Sackett, C. A., Wood, C. S., Itano, W. M., et al. (2000) · Physical Review A · doi:10.1103/physreva.61.063418 · Cited by 544
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543 · cited 3×
“A dual 920 km link was implemented in this way (Predehl et al 2012) and subsequently used to measure the transition frequency in atomic hydrogen remotely in the lab in MPQ Garching, near Munich (Matveev et al 2013).”
Self-citationDe Bièvre, P. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.09.007 · Cited by 527
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495 · cited 4×
“These are important ingredients for actual campaigns outside metrology laboratories and a transportable lattice clock, shown in figure 21, was indeed used for out-of-the-labora-tory experiments with negligible metrological infrastructure (Grotti et al 2018).”
InfluentialSelf-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468 · cited 4×
“…comparisons have already been used in several pathfinder experiments testing fundamental physics (Blatt et al 2008, Rosenband et al 2008, Le Targat et al 2013, Godun et al 2014, Huntemann et al 2014, Delva et al 2017), or demonstrating chronometric levelling (Lisdat et al 2016, Takano et al 2016).”
InfluentialMaking optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462 · cited 1×
“cy shift due to thermal noise can be reduced by using long cavities made from titanium-doped glass (e.g. ULETM) and fused silica mirrors (Amairi et al., 2013; Keller et al.,2013; Häfner et al., 2015; Jiang et al., 2011; Young et al., 1999). This way, an instability below 10−16 from 1 to 1000 s has been achieved et al.…”
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 7×
“…the accuracy of this clock comparison — corresponding to about 18 m in terms of height difference — did not reach the resolution demonstrated by Lisdat et al (2016) and Takano et al (2016) or , it was the first demonstration of a full chronometric levelling experiment with an optical clock,…”
InfluentialSelf-citationSchubert, G. (2007) · Cited by 453
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431 · cited 1×
“…in this regime that were necessary for high precision spectroscopic application such as the determination of the hydrogen 1S – 2S two-photon transition frequency (Niering et al 2000, Fischer et al 2004, Parthey et al 2011) or the 40 Ca + clock transition frequency (Chwalla et al 2009).”
Geodetic Reference System 1980
Moritz, H. (2000) · Journal of Geodesy · doi:10.1007/s001900050278 · Cited by 431
Tscherning, C. C. (1982) · Eos, Transactions American Geophysical Union · doi:10.1029/eo063i021p00514-03 · Cited by 427
Revolution in Time: Clocks and the Making of the Modern World
Brown, R. D., & Landes, D. S. (1984) · The American Historical Review · doi:10.2307/1866424 · Cited by 426
Improved Measurement of the Hydrogen1S–2STransition Frequency
Parthey, C. G., Matveev, A., Alnis, J., Bernhardt, B., Beyer, A., Holzwarth, R., Maistrou, A., Pohl, R., Predehl, K., Udem, T., et al. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.203001 · Cited by 423 · cited 2×
“…in this regime that were necessary for high precision spectroscopic application such as the determination of the hydrogen 1S – 2S two-photon transition frequency (Niering et al 2000, Fischer et al 2004, Parthey et al 2011) or the 40 Ca + clock transition frequency (Chwalla et al 2009).”
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413 · cited 2×
“Finally, motional shifts due to excess ion heating (Brownnutt et al. 2015), the stability of crystal configurations and a complex spectrum of motional modes are expected to place a limit on the controllable ion number.”
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Soffel, M., Klioner, S. A., Petit, G., Wolf, P., Kopeikin, S. M., Bretagnon, P., Brumberg, V. A., Capitaine, N., Damour, T., Fukushima, T., et al. (2003) · The Astronomical Journal · doi:10.1086/378162 · Cited by 392 · cited 4×
“the geocentre of the Earth and is a non-rotating system: for further detail see (Soffel et al. 2003).”
Influential(1962) · Israel Program for Scientific Translations eBooks · Cited by 386
High-stability transfer of an optical frequency over long fiber-optic links
Williams, P. A., Swann, W. C., & Newbury, N. R. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001284 · Cited by 385
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385 · cited 1×
“There, instead of focusing on improved laser coherence, a virtually dead time free interrogation scheme was implemented by interleaving the interrogation of two samples of atoms in independent physics packages (Schioppo et al 2017).”
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384 · cited 5×
“Beyond the aspect of reduced averaging time, the outstanding spectral resolution allows to resolve inhomogeneous influences on the transition frequency of the reference transition caused by e.g. interactions between atoms (Martin et al 2013) or with the trapping light field (Campbell et al 2017).”
InfluentialTenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382 · cited 2×
“In combination with new materials for the mirror coatings exhibiting smaller thermal noise (Cole et al 2013, 2016), further improved coherence properties of transportable lasers can be expected.”
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366 · cited 3×
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 1016 (Campbell et al., 2008; Falke et al., 2014; Huntemann et al., 2014; Kim et al., 2017; Oskay et al., 2006; Pizzocaro et al., 2017; Tamm et al., 2014, Le Targat et al., 2013).”
‘Designer atoms’ for quantum metrology
Roos, C. F., Chwalla, M., Kim, K., Riebe, M., & Blatt, R. (2006) · Nature · doi:10.1038/nature05101 · Cited by 343 · cited 2×
“With the use of multiple ions for precision spectroscopy, also clock operation using specially engineered substates, which are protected against systematic shifts can be envisioned (Roos et al 2006, Ludlow et al 2015).”
InfluentialNew Limits on Coupling of Fundamental Constants to Gravity UsingSr87Optical Lattice Clocks
Blatt, S., Ludlow, A. D., Campbell, G. K., Thomsen, J. W., Zelevinsky, T., Boyd, M. M., Ye, J., Baillard, X., Fouché, M., Le Targat, R., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.140801 · Cited by 333 · cited 2×
“Optical clock comparisons have already been used in several pathfinder experiments testing fundamental physics (Blatt et al 2008, Rosenband et al 2008, Le Targat et al 2013, Godun et al 2014, Huntemann et al 2014, Delva et al 2017), or demonstrating chronometric levelling (Lisdat et al 2016, Takano…”
InfluentialOptical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Self-citationSantarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314 · cited 3×
“However, since lattice clocks require significant time for loading and preparing the atoms (Tc > T), they are limited by the so-called Dick effect (Dick, 1987; Dick et al., 1990; Quessada et al., 2003; Santarelli et al., 1998).”
Experiments with an isolated subatomic particle at rest
Dehmelt, H. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.525 · Cited by 302
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301 · cited 2×
“, 2012) and (88)Sr (Barwood et al., 2014; Dubé et al., 2013 and 2017, Madej et al., 2004, 2012; Margolis et al., 2004) have also been investigated by several groups as frequency standards.”
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297 · cited 2×
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 1016 (Campbell et al., 2008; Falke et al., 2014; Huntemann et al., 2014; Kim et al., 2017; Oskay et al., 2006; Pizzocaro et al., 2017; Tamm et al., 2014, Le Targat et al., 2013).”
InfluentialGhosh, P. K. (1995) · doi:10.1093/oso/9780198539957.001.0001 · Cited by 296
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291 · cited 4×
“This 1400 km long, first international stabilised optical frequency link enabled frequency comparisons between LNE-SYRTE in Paris and PTB in Braunschweig, spanning a geographical distance of 700 km. Agreement of the clock frequencies limited by the uncertainty budget of the clocks themselves was found: for primary fre…”
Influential8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Self-citationPorsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279 · cited 2×
“Neglecting higher order effects, it can be written as (Pal’chikov et al., 2003; Porsev and Derevianko, 2006):”
InfluentialInteractions of Blackbody Radiation with Atoms
Gallagher, T. F., & Cooke, W. E. (1979) · Physical Review Letters · doi:10.1103/physrevlett.42.835 · Cited by 274 · cited 2×
“radiation (BBR) shift, which arises from thermal radiation interacting with the polarizability of the clock levels, also known as the ac Stark effect (Gallagher and Cooke, 1979; Itano et al., 1982).”
A Modified "Allan Variance" with Increased Oscillator Characterization Ability
Allan, D. W., & Barnes, J. A. (1981) · Thirty Fifth Annual Frequency Control Symposium · doi:10.1109/freq.1981.200514 · Cited by 270 · cited 5×
“…term timing instability of σ x ( τ ) = 8 × 10 − 10 ( τ /s) − 1/2 was reported between 1 s and 100 s; this would result in a frequency instability expressed as modified Allan deviation (MDEV) (Allan and Barnes 1981) mod σ y ( τ ) = 1.4 × 10 − 9 ( τ /s) − 3/2 , i.e. reaching 1.4 × 10 − 12 at 100 s.”
InfluentialRiehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264 · cited 4×
“Beyond this, optical clock networks and corresponding link technologies are currently established or are under discussion, from which distinct advantages are expected for the dissemination of time, geodesy, astronomy and basic research; for a review see (Riehle 2017).”
InfluentialExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250 · cited 3×
“The standard is operated as a clock by counting the number of cycles that have passed since a well-defined starting time (Le Targat et al 2013, Grebing et al 2016).”
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245 · cited 12×
“These are typically group-II like atoms; most often Sr (Nicholson et al. 2015; Tanabe et al. 2015; Lin et al. 2015; Lodewyck et al. 2016; Grebing et al. 2016; Takano et al. 2016; Hachisu et al. 2017), Yb (Takamoto et al.”
InfluentialUltrastable lasers based on vibration insensitive cavities
Millo, J., Magalhães, D. V., Mandache, C., Le Coq, Y., English, E. M. L., Westergaard, P. G., Lodewyck, J., Bize, S., Lemonde, P., & Santarelli, G. (2009) · Physical Review A · doi:10.1103/physreva.79.053829 · Cited by 244
Kerr-lens, mode-locked lasers as transfer oscillators for optical frequency measurements
Telle, H. R., Lipphardt, B., & Stenger, J. (2002) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400100735 · Cited by 242 · cited 4×
“Stabilization of the entire comb in all optical-optical comparisons can be avoided by employing a transfer scheme in which the noise of the comb is eliminated electronically (Scharnhorst et al., 2015; Stenger et al., 2002; Telle et al., 2002).”
InfluentialHigh-Accuracy Optical Clock Based on the Octupole Transition inYb+171
Huntemann, N., Okhapkin, M., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241 · cited 1×
“Besides atomic states with J ⩽ ½ , also the octupole transition to the highly shielded F state of the Yb + ion with low quadrupole moment can be a possible candidate for a multi-ion approach (Huntemann et al 2012).”
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238 · cited 7×
“8) that combine the advantages of rigid mounting and vibration noise suppression (Webster and Gill 2011; Vogt et al. 2011; Leibrandt et al. 2011; Argence et al. 2012; Chen et al. 2014; Parker et al. 2014; Didier et al. 2016; Świerad et al. 2016; Koller et al. 2017), which have successfully demonstrated transportation…”
InfluentialSelf-citationA test of the equivalence principle using a space-borne clock
Vessot, R. F. C., & Levine, M. W. (1979) · General Relativity and Gravitation · doi:10.1007/bf00759854 · Cited by 234 · cited 1×
“…of the gravity redshift to date was performed with an atomic clock in space, in the frame of the Gravity Probe-A (GP-A) mission in 1976, during which the frequency of a hydrogen maser launched on a rocket to 10 000 km altitude was compared to a hydrogen maser on ground (Vessot and Levine 1976).”
Observation of theS01→P03Clock Transition inAl+27
Rosenband, T., Schmidt, P., Hume, D., Itano, W., Fortier, T., Stalnaker, J., Kim, K., Diddams, S., Koelemeij, J., Bergquist, J., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.220801 · Cited by 231 · cited 1×
“This way, a relative coherence time of T c = 9.7 + 6.9 − 3.1 s was demonstrated, limited by the excited state lifetime of 20.6 ± 1.4 s (Rosenband et al 2007). extended This scheme can also be to frequency comparisons between ion and lattice clocks to take advantage of the high stability of a…”
InfluentialSelf-citationCoherent transfer of an optical carrier over 251 km
Newbury, N. R., Williams, P. A., & Swann, W. C. (2007) · Optics Letters · doi:10.1364/ol.32.003056 · Cited by 228
Precision Measurement of the Hydrogen1S−2SFrequency via a 920-km Fiber Link
Matveev, A., Parthey, C. G., Predehl, K., Alnis, J., Beyer, A., Holzwarth, R., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.230801 · Cited by 227 · cited 2×
“A dual 920 km link was implemented in this way (Predehl et al 2012) and subsequently used to measure the transition frequency in atomic hydrogen remotely in the lab in MPQ Garching, near Munich (Matveev et al 2013).”
Self-citationTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227 · cited 4×
“…European network incorporates a 340 km base-line link between London and Paris: first data have been used already from comparisons between NPL-LNE/SYRTE and LNE/SYRTE-PTB to test special relativity by a detailed analysis of the diurnal dependence of optical clock frequencies (Delva et al 2017).”
InfluentialSelf-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Frequency Standards: Basics and Applications
Riehle, F. (2003) · Wiley eBooks · doi:10.1002/3527605991 · Cited by 224 · cited 2×
“The broader physics background of frequency standards and physical geodesy can be found in text books e.g. (Audoin and Guinot 2001, Riehle 2004) and (Heiskanen and Moritz 1967, Torge and M ü ller 2012), respectively.”
Relativistic Celestial Mechanics of the Solar System
Kopeikin, S., Efroimsky, M., & Kaplan, G. (2011) · Wiley eBooks · doi:10.1002/9783527634569 · Cited by 222
External-field shifts of the 199-Hg(+) optical frequency standard
Itano, W. M. (2000) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.105.065 · Cited by 221 · cited 6×
“The latter can interact with an electric quadrupole of the electron distribution of the ion, resulting in the electric quadrupole shift (Itano 2000).”
InfluentialFrequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221 · cited 2×
“This approach however realizes its full potential only for clocks operating at the same (or very similar) frequencies (Nemitz et al 2016) and in situations, where interrogation light with identical spectral properties can be provided to both systems.”
Torge, W., & Müller, J. (2012) · doi:10.1515/9783110250008 · Cited by 220
Shift ofS122hyperfine splittings due to blackbody radiation
Itano, W. M., Lewis, L. L., & Wineland, D. J. (1982) · Physical Review A · doi:10.1103/physreva.25.1233 · Cited by 219 · cited 1×
“Another example is the black-body radiation (BBR) shift, which arises from thermal radiation interacting with the polarizability of the clock levels, also known as the ac Stark effect (Gallagher and Cooke 1979, Itano et al 1982).”
Delivery of high-stability optical and microwave frequency standards over an optical fiber network
Ye, J., Peng, J.-L., Jones, R. J., Holman, K. W., Hall, J. L., Jones, D. J., Diddams, S. A., Kitching, J., Bize, S., Bergquist, J. C., et al. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.001459 · Cited by 206 · cited 3×
“Previous reviews of fibre optical frequency and time transfer can be found in Ye et al (2003), Foreman et al (2007a) and Lopez et al (2015).”
Comparison of Two Independent Sr Optical Clocks with1×10−17Stability at103 s
Nicholson, T. L., Martin, M. J., Williams, J. R., Bloom, B. J., Bishof, M., Swallows, M. D., Campbell, S. L., & Ye, J. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230801 · Cited by 205 · cited 1×
“, 2010a) and single-ensemble neutral atom lattice clocks (Al-Masoudi et al., 2015; Nicholson et al., 2012) together with the instability given by MDEV (Allan and Barnes 1981) of a 1400 km long fibre link between PTB and Strasbourg (Raupach et al.”
Quantum tests of the Einstein Equivalence Principle with the STE–QUEST space mission
Altschul, B., Bailey, Q. G., Blanchet, L., Bongs, K., Bouyer, P., Cacciapuoti, L., Capozziello, S., Gaaloul, N., Giulini, D., Hartwig, J., et al. (2015) · Advances in Space Research · doi:10.1016/j.asr.2014.07.014 · Cited by 204
Wunsch, C., & Gaposchkin, E. M. (1980) · Reviews of Geophysics · doi:10.1029/rg018i004p00725 · Cited by 201 · cited 2×
“…(geoid) is denoted as the (mean) dynamic ocean topography (DOT); it reaches maximum values of about ± 2 m (Rapp and Balasubramania 1992, Bosch and Savcenko 2010) and is of vital importance for oceanog-raphers for deriving ocean circulation models (Wunsch and Gaposchkin 1980, Condi and Wunsch 2004).”
Refractive Index of Several Glasses as a Function of Wavelength and Temperature*
Wray, J. H., & Neu, J. T. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000774 · Cited by 198
A Quantum Many-Body Spin System in an Optical Lattice Clock
Martin, M. J., Bishof, M., Swallows, M. D., Zhang, X., Benko, C., von-Stecher, J., Gorshkov, A. V., Rey, A. M., & Ye, J. (2013) · Science · doi:10.1126/science.1236929 · Cited by 196 · cited 2×
“Beyond the aspect of reduced averaging time, the outstanding spectral resolution allows to resolve inhomogeneous influences on the transition frequency of the reference transition caused by e.g. interactions between atoms (Martin et al 2013) or with the trapping light field (Campbell et al 2017).”
LOCAL OSCILLATOR INDUCED INSTABILITIES IN TRAPPED ION FREQUENCY STANDARDS
Dick, G. J. (1987) · Cited by 193
Kerr-lens mode-locked lasers as transfer oscillators for optical frequency measurements
Telle, H. R., Lipphardt, B., & Stenger, J. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 191
Recoilless optical absorption and Doppler sidebands of a single trapped ion
Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1987) · Physical Review A · doi:10.1103/physreva.36.428 · Cited by 186 · cited 2×
“…of this ideal situation has been achieved through the development of laser cooling techniques (Chu 1998, Cohen-Tannoudji 1998, Phillips 1998) and by trapping the atoms either in an optical lattice (Katori et al 2003) or in an ion trap (Bergquist et al 1987) under ultra-high vacuum conditions.”
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182 · cited 1×
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 1016 (Campbell et al., 2008; Falke et al., 2014; Huntemann et al., 2014; Kim et al., 2017; Oskay et al., 2006; Pizzocaro et al., 2017; Tamm et al., 2014, Le Targat et al., 2013).”
Self-citationHigh-performance near- and mid-infrared crystalline coatings
Cole, G. D., Zhang, W., Bjork, B. J., Follman, D., Heu, P., Deutsch, C., Sonderhouse, L., Robinson, J., Franz, C., Alexandrovski, A., et al. (2016) · Optica · doi:10.1364/optica.3.000647 · Cited by 179 · cited 2×
“In combination with new materials for the mirror coatings exhibiting smaller thermal noise (Cole et al 2013, 2016), further improved coherence properties of transportable lasers can be expected.”
Ultra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
Drewes, H., Kuglitsch, F., Adám, J., & Rózsa, S. (2016) · Journal of Geodesy · doi:10.1007/s00190-016-0948-z · Cited by 174
(2009) · doi:10.1007/978-3-642-02687-4 · Cited by 174 · cited 1×
“Facing the societal challenges ongoing with climatic change and increasing population, the IAG initiated the Global Geodetic Observing System (GGOS; Plag and Pearlman 2009) with the aim to integrate different geodetic techniques for providing the observational base to monitor phenomena and…”
High-resolution microwave frequency dissemination on an 86-km urban optical link
Lopez, O., Amy-Klein, A., Lours, M., Chardonnet, C., & Santarelli, G. (2010) · Applied Physics B · doi:10.1007/s00340-009-3832-1 · Cited by 172 · cited 2×
“2015); ii) repeater lasers/ signal regeneration – (Foreman et al. 2007b; Lopez et al. 2010; Lopez et al. 2012; Lopez et al., 2015; Chiodo et al. 2015); iii) Raman amplification – (Clivati et al.”
Serrano, J., Fleck, T., Alvarez, P., Bär, R., Kreider, M., Lewis, J., Loschmidt, P., Rauch, S., Cota, E. G., Włostowski, T., et al. (2009) · CERN Document Server (European Organization for Nuclear Research) · Cited by 172
1 × 10−16frequency transfer by GPS PPP with integer ambiguity resolution
Petit, G., Kanj, A., Loyer, S., Delporte, J., Mercier, F., & Perosanz, F. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/301 · Cited by 168 · cited 5×
“In addition to cost considerations, having to share commercial satellite transponders impedes improvements (towards lower time and frequency transfer uncertainty), as the signal strength, the usable bandwidth and the experiment durations are constrained (Petit et al 2015a, Huang et al 2016a).”
InfluentialHigh-accuracy coherent optical frequency transfer over a doubled 642-km fiber link
Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., et al. (2014) · Applied Physics B · doi:10.1007/s00340-014-5917-8 · Cited by 168 · cited 3×
“2009), with a variant using only one optical fibre but different frequencies (Calonico et al. 2014).”
High resolution frequency standard dissemination via optical fiber metropolitan network
Narbonneau, F., Lours, M., Bize, S., Clairon, A., Santarelli, G., Lopez, O., Daussy, C., Amy-Klein, A., & Chardonnet, C. (2006) · Review of Scientific Instruments · doi:10.1063/1.2205155 · Cited by 166 · cited 8×
“A similar approach was used already much earlier for rf-fibre links in France (Narbonneau et al. 2006), which supported remote measurements of transition in the OsO4-molecule over a distance of 43 km (Daussy et al.”
InfluentialLong-distance frequency transfer over an urban fiber link using optical phase stabilization
Jiang, H., Kéfélian, F., Crane, S., Lopez, O., Lours, M., Millo, J., Holleville, D., Lemonde, P., Chardonnet, C., Amy-Klein, A., et al. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.002029 · Cited by 166 · cited 2×
“Link characterization is most often based on forming a loop, transporting the frequency information to a far-away lab on one fibre and back to the origin on a second fibre (Jiang et al. 2008; Grosche et al. 2009), with a variant using only one optical fibre but different frequencies (Calonico et al.”
Bjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165 · cited 5×
“The method of deriving potential differences from clock frequency comparisons has variously been termed ‘ chronometric level-ling ’ , ‘ relativistic geodesy ’ , or ‘ chronometric geodesy ’ (Bjerhammar 1975, Vermeer 1983, Bjerhammar 1985, Shen et al 2011, Delva and Lodewyck 2013), and throughout this paper we will use…”
InfluentialAbsolute Frequency Measurement of theCa+404s S1/22−3d D5/22Clock Transition
Chwalla, M., Benhelm, J., Kim, K., Kirchmair, G., Monz, T., Riebe, M., Schindler, P., Villar, A. S., Hänsel, W., Roos, C. F., et al. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.023002 · Cited by 164 · cited 3×
“2011) or the (40)Ca clock transition frequency (Chwalla et al. 2009).”
Synchronization of Distant Optical Clocks at the Femtosecond Level
Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R. (2016) · Physical Review X · doi:10.1103/physrevx.6.021016 · Cited by 164 · cited 2×
“As a future vision, we may see a combination of satellite methods (to link the continents), possibly using optical techniques based on femto-second pulse transfer (Deschênes et al. 2016), and national”
Quantum cascade laser frequency stabilization at the sub-Hz level
Argence, B., Chanteau, B., Lopez, O., Nicolodi, D., Abgrall, M., Chardonnet, C., Daussy, C., Darquié, B., Le Coq, Y., & Amy-Klein, A. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.93 · Cited by 162 · cited 3×
“A similar approach was used already much earlier for rf-fibre links in France (Narbonneau et al 2006), which supported remote measurements of transition in the OsO 4 -molecule over a distance of 43 km (Daussy et al 2005), and remote frequency synthesis (Argence et al 2015).”
Optical frequency transfer via 146 km fiber link with 10^−19 relative accuracy
Grosche, G., Terra, O., Predehl, K., Holzwarth, R., Lipphardt, B., Vogt, F., Sterr, U., & Schnatz, H. (2009) · Optics Letters · doi:10.1364/ol.34.002270 · Cited by 161 · cited 10×
“After the 146 km loop PTB-Hanover-PTB had been tested down to the 1×10 level (Grosche et al. 2009), an ultra-stable laser in the near-infrared was remotely characterised in Hanover (via 73 km fibre) with sub Hz-resolution (Pape et al.”
InfluentialSelf-citationEGM_TIM_RL05: An independent geoid with centimeter accuracy purely based on the GOCE mission
Brockmann, J. M., Zehentner, N., Höck, E., Pail, R., Loth, I., Mayer‐Gürr, T., & Schuh, W. (2014) · Geophysical Research Letters · doi:10.1002/2014gl061904 · Cited by 160 · cited 2×
“2017); this estimate represents an optimistic scenario and it is only valid for the case that a state-of-the-art global geopotential model (e.g. 5th generation GOCE model; Brockmann et al. 2014) and sufficient high resolution and quality terrestrial data sets (especially gravity measurements with a spacing of a few km…”
Optical Lattice Induced Light Shifts in an Yb Atomic Clock
Barber, Z., Stalnaker, J., Lemke, N., Poli, N., Oates, C., Fortier, T., Diddams, S., Hollberg, L., Hoyt, C., Taichenachev, A., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.103002 · Cited by 160
Optimal Design of Dipole Potentials for Efficient Loading of Sr Atoms
Katori, H., Ido, T., & Kuwata-Gonokami, M. (1999) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.68.2479 · Cited by 157 · cited 1×
“…species that provide sufficiently narrow clock transitions and have a level structure that allows to operate an optical trap i.e. the lattice at a wavelength (so-called ‘ magic ’ wavelength) where the polarizabilities of upper and lower clock state are equal (Katori et al 1999 (Kulosa et al 2015).”
Madej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155
Ultraprecise Measurement of Optical Frequency Ratios
Stenger, J., Schnatz, H., Tamm, C., & Telle, H. R. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.073601 · Cited by 155 · cited 2×
“Stabilization of the entire comb in all optical-optical comparisons can be avoided by employing a transfer scheme in which the noise of the comb is eliminated electronically (Scharnhorst et al., 2015; Stenger et al., 2002; Telle et al., 2002).”
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154 · cited 3×
“Its uncertainty arises from imprecise knowledge of Δαs (uncertainty δΔαs), obtained from measurements (Dubé et al., 2014; Huntemann et al., 2016; Middelmann et al., 2012; Sherman et al., 2012) or calculations (Safronova et al.”
Self-citationLong-Distance Frequency Dissemination with a Resolution of10−17
Daussy, C., Lopez, O., Amy-Klein, A., Goncharov, A., Guinet, M., Chardonnet, C., Narbonneau, F., Lours, M., Chambon, D., Bize, S., et al. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.203904 · Cited by 153 · cited 2×
“A similar approach was used already much earlier for rf-fibre links in France (Narbonneau et al 2006), which supported remote measurements of transition in the OsO 4 -molecule over a distance of 43 km (Daussy et al 2005), and remote frequency synthesis (Argence et al 2015).”
Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards
Dubé, P., Madej, A. A., Bernard, J. E., Marmet, L., Boulanger, J.-S., & Cundy, S. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.033001 · Cited by 152 · cited 1×
“It can be eliminated by averaging over several clock transitions (Dub é et al 2005, p 20), similar to the linear Zeeman effect, or by applying a magnetic field along three mutually orthogonal directions (Itano 2000), which can also be viewed as averaging over three different transitions.”
The absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151 · cited 1×
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 10 16 (Oskay et al 2006, Campbell et links as discussed in section 6.2 is achieved by stabilizing the output of a laser operating near the target wavelength with one of the stabilized comb teeth.”
InfluentialHeight datum definition, height datum connection and the role of the geodetic boundary value problem
Rummel, R., & Teunissen, P. J. G. (1988) · Journal of Geodesy · doi:10.1007/bf02520239 · Cited by 150 · cited 1×
“…the above approach (equations (2.16) and (2.17) is denoted here somewhat loosely as the GNSS/geoid approach, which is also known in the literature as the GNSS/GBVP approach (the GBVP is the basis for computing the disturbing potential T ; see, e.g. Rummel and Teunissen 1988, Heck and Rummel 1990).”
InfluentialAgnew, D. C. (2007) · Elsevier eBooks · doi:10.1016/b978-044452748-6.00056-0 · Cited by 150
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149 · cited 5×
“These are typically group-II like atoms; most often Sr (Nicholson et al. 2015; Tanabe et al. 2015; Lin et al. 2015; Lodewyck et al. 2016; Grebing et al. 2016; Takano et al. 2016; Hachisu et al. 2017), Yb (Takamoto et al.”
InfluentialSelf-citationRapp, R. H. (1997) · Journal of Geodesy · doi:10.1007/s001900050096 · Cited by 147 · cited 3×
“10) can be combined to derive the difference H– H or N–ζ, which can reach several centimetres to about 1 dm in low mountain ranges, about 3–5 dm (or even more) in the high mountains such as the European Alps or the Rocky Mountains, and about 3 m in the Himalayan Mountains (Rapp 1997; Marti and Schlatter 2001), while o…”
InfluentialStable Photonic Links for Frequency and Time Transfer in the Deep-Space Network and Antenna Arrays
Calhoun, M., Huang, S., & Tjoelker, R. L. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.905048 · Cited by 147 · cited 2×
“Additionally, already from the 1980s, reference frequencies (and later time-stamps) were distributed via rf signals over a few km to several sites, in support of the deep space network, see (Calhoun et al. 2007).”
The Confrontation Between General Relativity and Experiment
Will, C. M. (2009) · Space sciences series of ISSI · doi:10.1007/978-1-4419-1362-3_2 · Cited by 146
86-km optical link with a resolution of 2 × 10-18 for RF frequency transfer
Lopez, O., Amy-Klein, A., Daussy, C., Chardonnet, C., Narbonneau, F., Lours, M., & Santarelli, G. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00059-5 · Cited by 145 · cited 1×
“…− 17 (at 10 5 s) already in 2006 using 100 MHz rf-modulation, and impressive developments reaching to a few 10 − 19 (at 10 5 s) in 2010 using microwave modulation at 9 GHz over a distance of 86 km, are documented in Narbonneau et al (2006), Lopez et al (2008, 2010a) and led to several applications.”
Vibration-insensitive reference cavity for an ultra-narrow-linewidth laser
Nazarova, T., Riehle, F., & Sterr, U. (2006) · Applied Physics B · doi:10.1007/s00340-006-2225-y · Cited by 145
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination
Lopez, O., Haboucha, A., Kéfélian, F., Jiang, H., Chanteau, B., Roncin, V., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2010) · Optics Express · doi:10.1364/oe.18.016849 · Cited by 144 · cited 1×
“…− 17 (at 10 5 s) already in 2006 using 100 MHz rf-modulation, and impressive developments reaching to a few 10 − 19 (at 10 5 s) in 2010 using microwave modulation at 9 GHz over a distance of 86 km, are documented in Narbonneau et al (2006), Lopez et al (2008, 2010a) and led to several applications.”
Fundamental limits on the frequency stabilities of crystal oscillators
Walls, F. L., & Vig, J. R. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.393101 · Cited by 144 · cited 1×
“In the early twentieth century, with the invention of quartz crystal oscillators (Walls and Vig 1995), a major leap in frequency resolution and accuracy was realized, translating to an uncertainty of time measurement of only 200 µ s per day.”
Time transfer with nanosecond accuracy for the realization of International Atomic Time
Piester, D., Bauch, A., Breakiron, L., Matsakis, D., Blanzano, B., & Koudelka, O. (2008) · Metrologia · doi:10.1088/0026-1394/45/2/008 · Cited by 143 · cited 1×
“…both directions and periodic variations up to 2 ns d − 1 (equivalent to frequency variations exceeding 10 − 14 ) have been observed in transcon-tinental links (Piester et al 2008b) — different thermal gradients as the satellite rotates daily with respect to the sun are believed to be responsible.”
Coherent Optical Phase Transfer over a 32-km Fiber with 1 s Instability at10−17
Foreman, S. M., Ludlow, A. D., de Miranda, M. H. G., Stalnaker, J. E., Diddams, S. A., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.153601 · Cited by 141
Blackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, U. I., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140
Vibration insensitive optical cavity
Webster, S. A., Oxborrow, M., & Gill, P. (2007) · Physical Review A · doi:10.1103/physreva.75.011801 · Cited by 140
The manipulation of neutral particles
Chu, S. (1998) · Cited by 139
Hyper-Ramsey spectroscopy of optical clock transitions
Yudin, V. I., Taichenachev, A. V., Oates, C. W., Barber, Z. W., Lemke, N. D., Ludlow, A. D., Sterr, U., Lisdat, C., & Riehle, F. (2010) · Physical Review A · doi:10.1103/physreva.82.011804 · Cited by 139 · cited 3×
“Power broadening of the narrow clock transition by the clock laser results in significant ac Stark shifts that are nulled by a special pulse sequence called Hyper-Ramsey (Hobson et al., 2016; Huntemann et al., 2012a; Yudin et al., 2010; Zanon-Willette et al., 2016).”
InfluentialSelf-citationAtomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137 · cited 1×
“…al 2012, Middelmann et al 2012, Sherman et al 2012, Nicholson et al 2015) and sophisticated temperature control systems have been implemented in the apparatuses, both for operation at room temperature (Beloy et al 2014, Bloom et al 2014) as well as for cryogenic environments (Ushijima et al 2015).”
Force-insensitive optical cavity
Webster, S., & Gill, P. (2011) · Optics Letters · doi:10.1364/ol.36.003572 · Cited by 137 · cited 1×
“8) that combine the advantages of rigid mounting and vibration noise suppression (Webster and Gill 2011; Vogt et al. 2011; Leibrandt et al. 2011; Argence et al. 2012; Chen et al. 2014; Parker et al. 2014; Didier et al. 2016; Świerad et al. 2016; Koller et al. 2017), which have successfully demonstrated transportation…”
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137 · cited 4×
“If the change in frequency cannot be made very large, averaging to the desired level of uncertainty can be tedious and take a long time if the targeted accuracy is high (Westergaard et al 2011).”
InfluentialValidation of GOCE gravity field models by means of orbit residuals and geoid comparisons
Gruber, T., Visser, P. N. A. M., Ackermann, C., & Hosse, M. (2011) · Journal of Geodesy · doi:10.1007/s00190-011-0486-7 · Cited by 137 · cited 2×
“Results from both approaches show an agreement at the few centimetre level over a few 100 km distance, while being presently inconsistent at the decimetre level across Europe (see Kenyeres et al 2010, Gruber et al 2011, Denker et al 2017).”
Spectral purity transfer between optical wavelengths at the 10−18 level
Nicolodi, D., Argence, B., Zhang, W., Le Targat, R., Santarelli, G., & Le Coq, Y. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.361 · Cited by 132 · cited 2×
“This way, frequency stability transfer between different spectral regimes at the level of 4 × 10 − 18 has been achieved (Nicolodi et al 2014).”
High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock
Sherman, J. A., Lemke, N. D., Hinkley, N., Pizzocaro, M., Fox, R. W., Ludlow, A. D., & Oates, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153002 · Cited by 131 · cited 1×
“The atomic polarizabilities parametrizing this coupling have been accurately measured now (Beloy et al 2012, Middelmann et al 2012, Sherman et al 2012, Nicholson et al 2015) and sophisticated temperature control systems have been implemented in the apparatuses, both for operation at room…”
Thermal noise in optical cavities revisited
Kessler, T., Legero, T., & Sterr, U. (2012) · Journal of the Optical Society of America B · doi:10.1364/josab.29.000178 · Cited by 130
Frequency stabilization to 6 × 10−16 via spectral-hole burning
Thorpe, M. J., Rippe, L., Fortier, T. M., Kirchner, M. S., & Rosenband, T. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.215 · Cited by 129 · cited 1×
“Spectral hole burning is based on rare-earth doped crystals at cryogenic temperatures in which optical pumping with a laser pulse generates narrow resonances (spectral holes in the population), which in turn can be used to stabilize the laser ’ s frequency (Chen et al 2011, Thorpe et al 2011).”
Heisenberg-Limited Atom Clocks Based on Entangled Qubits
Kessler, E. M., Kómár, P., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.190403 · Cited by 127 · cited 4×
“Also, faster averaging, phase sensitive locking schemes are investigated (Borregaard and S ø rensen 2013, Rosenband and Leibrandt 2013, Kessler et al 2014), where multiple ensembles are employed to successively extend the clock laser coherence time in a cascade of measurements with increasing…”
InfluentialEvaluation of systematic shifts of the88Sr+single-ion optical frequency standard at the10−17level
Dubé, P., Madej, A. A., Zhou, Z., & Bernard, J. E. (2013) · Physical Review A · doi:10.1103/physreva.87.023806 · Cited by 127
Vibration-induced elastic deformation of Fabry-Perot cavities
Chen, L., Hall, J. L., Ye, J., Yang, T., Zang, E., & Li, T. (2006) · Physical Review A · doi:10.1103/physreva.74.053801 · Cited by 127 · cited 2×
“…length variations of the cavity and thus frequency instabilities of the laser, the cavity commonly lies on its support and is not rigidly clamped (Chen et For reasons of compactness and reduction of inertial forces, often cavities of only about 5 cm length have been chosen (Leibrandt et al…”
Laser frequency stabilization to a single ion
Peik, E., Schneider, T., & Tamm, C. (2006) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/39/1/012 · Cited by 125 · cited 1×
“For single ion clocks with limited signal-to-noise ratio, but very fast cycle times (Tc ≈ T), several probe cycles are required to stabilize the laser’s frequency to the atomic reference (Leroux et al., 2017; Peik et al., 2006; Riis and Sinclair, 2004).”
High-resolution microwave frequency dissemination on an 86km urban optical link
Lopez, O., Amy‐Klein, A., Lours, M., et al. (2009) · Cited by 125
Optical fibers in time and frequency transfer
Śliwczyński, Ł., Krehlik, P., & Lipiński, M. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/7/075302 · Cited by 120 · cited 3×
“For optical frequency transfer, the relevant changes in the signal delay τ 0 are dominated by environmental temper ature fluctuations, which change the refractive index n ; in the case of modulated signals, n is replaced by the group refractive index n g , see e.g. (Sliwczynski et al 2010).”
InfluentialAbsolute frequency measurement of the In^+ clock transition with a mode-locked laser
von Zanthier, J., Becker, T., Eichenseer, M., Nevsky, A. Y., Schwedes, C., Peik, E., Walther, H., Holzwarth, R., Reichert, J., Udem, T., et al. (2000) · Optics Letters · doi:10.1364/ol.25.001729 · Cited by 119
Prototype of an ultra-stable optical cavity for space applications
Argence, B., Prevost, E., Lévèque, T., Le Goff, R., Bize, S., Lemonde, P., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.025409 · Cited by 117 · cited 3×
“With designs using longer cavities, frequency instabilities approaching 5 × 10 − 16 and below have been achieved (Argence et al 2012, Voigt et al 2016, Koller et al 2017), promising better clock instability.”
Die Mathematischen und physikalischen Theorieen der höheren Geodäsie
Helmert, F. R. (1880) · Cited by 117
Spherical reference cavities for frequency stabilization of lasers in non-laboratory environments
Leibrandt, D. R., Thorpe, M. J., Notcutt, M., Drullinger, R. E., Rosenband, T., & Bergquist, J. C. (2011) · Optics Express · doi:10.1364/oe.19.003471 · Cited by 116 · cited 1×
“…frequency instabilities of the laser, the cavity commonly lies on its support and is not rigidly clamped (Chen et For reasons of compactness and reduction of inertial forces, often cavities of only about 5 cm length have been chosen (Leibrandt et al 2011b, Webster et al 2011, Parker et al 2014).”
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114 · cited 1×
“Line broadening by atomic motion is also inhibited by the quantized level structure in the trap (Lemonde and Wolf 2005).”
Precise determination of micromotion for trapped-ion optical clocks
Keller, J., Partner, H. L., Burgermeister, T., & Mehlstäubler, T. E. (2015) · Journal of Applied Physics · doi:10.1063/1.4930037 · Cited by 113 · cited 3×
“Stray electric fields or asymmetries in the rf field can cause excess micromotion, which can be compensated to reduce Doppler-induced frequency shifts (Berkeland et al. 1998; Keller et al., 2015).”
Self-citationMeasuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
Generalized Ramsey Excitation Scheme with Suppressed Light Shift
Huntemann, N., Lipphardt, B., Okhapkin, M., Tamm, C., Peik, E., Taichenachev, A. V., & Yudin, V. I. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.213002 · Cited by 112 · cited 2×
“Besides atomic states with J ⩽ ½ , also the octupole transition to the highly shielded F state of the Yb + ion with low quadrupole moment can be a possible candidate for a multi-ion approach (Huntemann et al 2012).”
Atomic Clocks and Oscillators for Deep-Space Navigation and Radio Science
Prestage, J. D., & Weaver, G. L. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.905130 · Cited by 112
Strategies for Solving the Vertical Datum Problem Using Terrestrial and Satellite Geodetic Data
Heck, B., & Rummel, R. (1990) · International Association of Geodesy symposia · doi:10.1007/978-1-4684-7098-7_14 · Cited by 111 · cited 1×
“…the above approach (equations (2.16) and (2.17) is denoted here somewhat loosely as the GNSS/geoid approach, which is also known in the literature as the GNSS/GBVP approach (the GBVP is the basis for computing the disturbing potential T ; see, e.g. Rummel and Teunissen 1988, Heck and Rummel 1990).”
InfluentialPrecision Calculation of Blackbody Radiation Shifts for Optical Frequency Metrology
Safronova, M. S., Kozlov, M. G., & Clark, C. W. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.143006 · Cited by 111 · cited 2×
“, 2017), has a small linear and quadratic Zeeman effect and exhibits the smallest sensitivity to black-body radiation of all investigated atomic species (Rosenband et al., 2006; Safronova et al., 2011).”
Brillouin amplification in phase coherent transfer of optical frequencies over 480 km fiber
Terra, O., Grosche, G., & Schnatz, H. (2010) · Optics Express · doi:10.1364/oe.18.016102 · Cited by 106 · cited 1×
“2015) and iv) fibre Brillouin amplification – (Ferreira et al. 1994; Terra et al. 2010; Raupach et al. 2014; Raupach et al. 2015; Soudi et al. 2016).”
Self-citationDubé, P., Madej, A. A., Tibbo, M., & Bernard, J. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.173002 · Cited by 106 · cited 2×
“2 × 10−17 (Dubé et al., 2014) inaccuracy and 3 × 10−17 reproducibility (Barwood et al.”
Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty
Yamaguchi, A., Fujieda, M., Kumagai, M., Hachisu, H., Nagano, S., Li, Y., Ido, T., Takano, T., Takamoto, M., & Katori, H. (2011) · Applied Physics Express · doi:10.1143/apex.4.082203 · Cited by 106 · cited 1×
“The dissemination of the clock frequencies involves, e.g. satellites (Hachisu et al 2014), but more often optical fibre links, discussed in section 6.2, are employed (Yamaguchi et al 2011, Lisdat et al 2016, Takano et al 2016).”
InfluentialFrequency Comparison of TwoCa+40Optical Clocks with an Uncertainty at the10−17Level
Huang, Y., Guan, H., Liu, P., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013001 · Cited by 106 · cited 7×
“In addition to cost considerations, having to share commercial satellite transponders impedes improvements (towards lower time and frequency transfer uncertainty), as the signal strength, the usable bandwidth and the experiment durations are constrained (Petit et al 2015a, Huang et al 2016a).”
InfluentialThe Dick effect for an optical frequency standard
Quessada, A., Kovacich, R. P., Courtillot, I. N., Clairon, A., Santarelli, G., & Lemonde, P. (2003) · Journal of Optics B: Quantum and Semiclassical Optics · doi:10.1088/1464-4266/5/2/373 · Cited by 104 · cited 1×
“However, since lattice clocks require significant time for loading and preparing the atoms (Tc > T), they are limited by the so-called Dick effect (Dick, 1987; Dick et al., 1990; Quessada et al., 2003; Santarelli et al., 1998).”
A transportable strontium optical lattice clock
Poli, N., Schioppo, M., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Applied Physics B · doi:10.1007/s00340-014-5932-9 · Cited by 104 · cited 3×
“Originally following the development of both Sr (Poli et al. 2014) and Yb lattice clocks (Mura et al.”
Self-citationFrequency Ratio ofHg199andSr87Optical Lattice Clocks beyond the SI Limit
Yamanaka, K., Ohmae, N., Ushijima, I., Takamoto, M., & Katori, H. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.230801 · Cited by 104 · cited 1×
“On the long run, optical ratio measurements (Rosenband et al 2008, Akamatsu et al 2014a, 2014b, Yamanaka et al 2015, Nemitz et al 2016, Grotti et al 2018) between clocks of different types will provide a matrix-like data field that will allow judging the quality of the clock uncertainty (Margolis…”
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102 · cited 1×
“These are typically group-II like atoms; most often Sr (Nicholson et al. 2015; Tanabe et al. 2015; Lin et al. 2015; Lodewyck et al. 2016; Grebing et al. 2016; Takano et al. 2016; Hachisu et al. 2017), Yb (Takamoto et al.”
Schilizzi, R. T., Dewdney, P. E., & Lazio, T. J. W. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.786780 · Cited by 102
Carrier-phase two-way satellite frequency transfer over a very long baseline
Fujieda, M., Piester, D., Gotoh, T., Becker, J., Aida, M., & Bauch, A. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/253 · Cited by 101 · cited 2×
“More recent TW-CP experiments reached a frequency instability (MDEV) close to 10 at 1 s and a few 10 beyond 2000 s (Fujieda et al. 2014).”
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101 · cited 2×
“Today, in optimal cases the long-term instability and uncertainty reaches 10 − 19 (Chiodo et al 2015), or even 2 × 10 − 20 over 1400 km (Raupach et al 2015).”
Self-citationA compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101 · cited 2×
“A more compact transportable clock based on a (40)Ca has been realized (Cao et al. 2017).”
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101 · cited 1×
“Therefore, methods have been devised that do not necessarily aim at a perfect cancellation of the lattice light shift but try to maintain an acceptably small shift over a reasonably large range of experimental conditions (Katori et al 2015, Ovsiannikov et al 2016, Brown et al 2017).”
Cascaded optical fiber link using the internet network for remote clocks comparison
Chiodo, N., Quintin, N., Stefani, F., Wiotte, F., Camisard, E., Chardonnet, C., Santarelli, G., Amy-Klein, A., Pottie, P.-E., & Lopez, O. (2015) · Optics Express · doi:10.1364/oe.23.033927 · Cited by 100 · cited 3×
“Today, in optimal cases the long-term instability and uncertainty reaches 10 − 19 (Chiodo et al 2015), or even 2 × 10 − 20 over 1400 km (Raupach et al 2015).”
Sympathetic cooling of mixed-species two-ion crystals for precision spectroscopy
Wübbena, J. B., Amairi, S., Mandel, O., & Schmidt, P. O. (2012) · Physical Review A · doi:10.1103/physreva.85.043412 · Cited by 99 · cited 1×
“By employing (25)Mg instead of (9)Be as the logic ion species, sympathetic cooling improved (Wübbena et al., 2012) and a second generation Al clock with an inaccuracy of 8 × 10−18 could be demonstrated (Chou et al.”
Self-citationCoherent optical link through the turbulent atmosphere
Djerroud, K., Acef, O., Clairon, A., Lemonde, P., Man, C. N., Samain, E., & Wolf, P. (2010) · Optics Letters · doi:10.1364/ol.35.001479 · Cited by 97 · cited 2×
“Encouraging earth-bound tests of free space optical frequency transfer have been performed over distances of several km (horizontally) both for a continuous optical carrier ((Djerroud et al. 2010), with a projected frequency uncertainty below 10), and for femtosecond-pulse transfer (Deschênes et al.”
Spectroscopy of the electric-quadrupole transition2S1/2(F=0)–2D3/2(F=2)in trapped171Yb+
Tamm, C., Engelke, D., & Bühner, V. (2000) · Physical Review A · doi:10.1103/physreva.61.053405 · Cited by 95 · cited 1×
“(b) Picture of a spherical ring trap such as used in (Tamm et al., 2000), courtesy Chr.”
Cascaded multiplexed optical link on a telecommunication network for frequency dissemination
Lopez, O., Haboucha, A., Kéfélian, F., Jiang, H., Chanteau, B., Roncin, V., Chardonnet, C., Amy‐Klein, A., & Santarelli, G. (2010) · HAL · Cited by 95
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 94
Self-citationMadej, A. A., Bernard, J. E., Dubé, P., Marmet, L., & Windeler, R. S. (2004) · Physical Review A · doi:10.1103/physreva.70.012507 · Cited by 92
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91 · cited 9×
“Based on the law of error propagation, the uncertainty (standard deviation) for a regionally computed height anomaly ζ, based on the combination of a global geopotential model with terrestrial data, is about 2 cm (Denker et al. 2017); this estimate represents an optimistic scenario and it is only valid for the case th…”
InfluentialSelf-citationAbsolute frequency measurement of the $In^{+}$ clock transition with a mode-locked laser
Von Zanthier, J., Becker, T., Eichenseer, M., et al. (2000) · CERN Document Server (European Organization for Nuclear Research) · Cited by 91
Sideband cooling of ions in radio-frequency traps
Peik, E., Abel, J., Becker, T., von Zanthier, J., & Walther, H. (1999) · Physical Review A · doi:10.1103/physreva.60.439 · Cited by 90 · cited 1×
“This easily scalable detection scheme and the possibility for direct laser cooling on the same transition (Peik et al 1995, 1999), make In + a ready candidate for a multi-ion approach.”
Agreement between two88Sr+optical clocks to 4 parts in 1017
Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P. (2014) · Physical Review A · doi:10.1103/physreva.89.050501 · Cited by 90 · cited 5×
“…lattice clocks to take advantage of the high stability of a lattice clock to correct phase excursions of the laser (Hume and Leibrandt 2016) The et al 2004, 2012, Margolis et al 2004, Dub é et al 2013, 2017, Barwood et al 2014) have also been investigated by several groups as frequency standards.”
Influential(2012) · International Association of Geodesy Symposia · doi:10.1007/978-3-642-20338-1 · Cited by 90
Sciences of Geodesy - I: Advances and Future Directions
Xu, G. (2010) · Springer eBooks · doi:10.1007/978-3-642-11741-1 · Cited by 89
Analysis of the gain and noise characteristics of fibre Brillouin amplifiers
Ferreira, M. F. S., da Rocha, J. R. F., & Pinto, J. L. (1994) · Optical and Quantum Electronics · doi:10.1007/bf00573899 · Cited by 86 · cited 1×
“25 m (Ma et al. 1994) or ~ 100 km about 10 years ago.”
Research works printed but not linked: 9
- Denker, H. (1998) Evaluation and improvement of the EGG97 quasigeoid model for Europe by GPS and leveling data. In: Vermeer, M., Ádám, J. (eds.), Second Continental Workshop on the Geoid in Europe, Proceed., Rep. Finnish Geod. Inst. 98:4: 53-61, Masala · DOI
- Dick, G.J., 1987. Local Oscillator Induced Instabilities in Trapped Ion Frequency Standards, in: Proc. 19th Annual Precise Time and Time Interval (PTTI) Application and Planning Meeting. pp. 133-147.
- Drewes H 2007 Science rational of the Global Geodetic Observation System (CGOS) in Internat. Ass. of Geodesy Symposia (Springer) vol 130 p.703
- Dubé P, Madej AA, Zhou Z, Bernard JE 2013 Evaluation of systematic shifts of the 88 Sr + single-ion optical frequency standard at the 10 -17 level. Physical Review A 87 023806
- Ghosh, P.K., 1995. Ion traps. Clarendon press.
- Herring, T. (2009) Overview. In: G. Schubert, T. Herring (eds.), Treatise on Geophysics, Vol. 3, Geodesy, 1-10, Elsevier, Amsterdam
- Rosenband, T., Itano, W.M., Schmidt, P.O., Hume, D.B., Koelemeij, J.C.J., Bergquist, J.C., Wineland, D.J., 2006. Blackbody radiation shift of the 27 Al + 1 S0 3 P0 transition, in: Proceedings of the 20th European Frequency and Time Forum. Presented at the EFTF, Braunschweig, Germany, pp. 289-291.
- Scheibe A., Adelsberger U. 1936 Nachweis von Schwankungen der astronomischen Tageslänge im Jahre 1935 mittels Quarzuhren Phys. Zeitschrift 37 38
- Strang van Hees, G.L. (1977) Zur zeitlichen Änderung von Schwere und Höhe. Zeitschrift für Vermessungswesen, 10, 444-450
Cited by
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Micius quantum experiments in space
Lu, C.-Y., Cao, Y., Peng, C.-Z., & Pan, J.-W. (2022) · Reviews of Modern Physics · doi:10.1103/revmodphys.94.035001 · Cited by 295
Energy of the 229Th nuclear clock transition
Seiferle, B., von der Wense, L., Bilous, P. V., Amersdorffer, I., Lemell, C., Libisch, F., Stellmer, S., Schumm, T., Düllmann, C. E., Pálffy, A., et al. (2019) · Nature · doi:10.1038/s41586-019-1533-4 · Cited by 230
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 208
“…as well as improved time synchronization for high-resolution telescope arrays and future VLBI Relativistic geodesy/alternative theories of gravitation generations [16], geopotential monitoring with centimetre resolution [17], quantum networks for quantum encrypted communications [18], and others.”
Background
Metadata
- Authors
- Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- Corresponding author
- Mehlstäubler, Tanja E
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2018-04-18
- Volume
- 81
- Issue
- 6
- Pages
- 064401
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2791228270
- Cited by
- 263
- References
- 406
- Citations by year
- 2026: 22 · 2025: 39 · 2024: 45 · 2023: 36 · 2022: 33 · 2021: 26 · 2020: 34 · 2019: 24 · 2018: 4
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Reports on Progress in Physics (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- optical atomic clocks, frequency transfer, geodesy, height reference system, clock comparison, tests of general relativity, portable atomic clock
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.