Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index; 18 of the 45 sources its claims cite were checked for support.
Abstract
Builds an error model for chronometric levelling and evaluates height-measurement schemes and accuracy requirements for optical clocks and transfer techniques.
Overview
CoChat Summary
TL;DR
This paper builds an error model for chronometric leveling with optical clocks and optical fiber frequency transfer, evaluates 16 clock/OFFT schemes, and derives accuracy requirements for height measurement targets from 5 cm to 0.1 cm. It finds that current transportable 40Ca+ clocks give ~21 cm experimental height uncertainty, while future ultra-high-precision clocks plus OFFT could reach ~4.2 mm and potentially support 1 cm global height datum unification.
Key findings
- The height uncertainty is modeled as σ = √(σ_sys² + σ_sta² + σ_path²), where σ_sys is the measurement systematic error of two optical clocks, σ_sta is their frequency statistical error, and σ_path is the optical-fiber transmission path error.
- In the APM 40Ca+ experiment, two transportable clocks connected by a 10 m fiber measured three heights with averages −0.05 m, −0.83 m, and 1.02 m; differences from classical geodetic values were 0.015 m, 0.038 m, and 0.052 m, and the final height uncertainty was about 21 cm. The corresponding theoretical scheme 1 gave about 18 cm, a difference of approximately 3 cm.
- Across 16 schemes, scheme 1 (two Clock 1 + OFFT A) reached 0.1807 m uncertainty; a pair of Clock 3 with OFFT C reached 0.0198 m; and Clock 4 with OFFT D reached 0.0042 m. The paper concludes that the fiber path error should be more than one order of magnitude lower than the clock systematic error, giving a path-error variance contribution of no more than 1%.
- For target height accuracies, 5 cm requires σ_sys = 4.86 × 10⁻¹⁸, σ_sta = 2.43 × 10⁻¹⁸, and σ_path = 4.86 × 10⁻¹⁹; 1 cm requires 9.71 × 10⁻¹⁹, 4.86 × 10⁻¹⁹, and 9.71 × 10⁻²⁰; 0.1 cm requires 9.71 × 10⁻²⁰, 4.86 × 10⁻²⁰, and 9.71 × 10⁻²¹. The highest-accuracy existing optical clock cited has a systematic error corresponding to 8.6 mm height uncertainty.
Methods
- Design: theoretical error modeling and performance evaluation for chronometric leveling, based on the gravitational redshift relation Δh ≈ 9.1 × 10¹⁷ (f₂ − f₁)/f₁ and covariance propagation of clock systematic, clock statistical, and fiber path errors.
- Data/sample: published optical clock and OFFT parameters are used to define four clocks (Clock 1–4) with systematic errors 1.3 × 10⁻¹⁷, 3 × 10⁻¹⁸, 9.4 × 10⁻¹⁹, and 3 × 10⁻¹⁹, and four OFFT systems (A–D) with noise floors from 2 × 10⁻¹⁸ to 2 × 10⁻²¹ and distances of 480, 920, 680, and 100 km; these are combined into 16 schemes. The paper also describes an APM experiment using two transportable 40Ca+ clocks, a 10 m fiber, and four observation periods.
- Analysis: Allan variance is used for frequency statistical error; requirement analysis solves for σ_sys, σ_sta, and σ_path under the assumptions σ_sys = 2σ_sta and σ_path = 0.1σ_sys.
Limitations
- Stated in the paper: the actual experiment was affected by the magnetic field around the site, limiting single-day observation to about 6 h; it was limited by clock-laser stability and observation time; continuous observation time is relatively short; and the authors cannot exclude drift, RWFM noise, or other noises during long-term observation.
- Stated assumptions: the theoretical evaluation assumes g = 9.8 m/s², σ_sys = 2σ_sta, and σ_path = 0.1σ_sys; Clock 4 is an assumed future ultra-high-precision clock; some extremely small systematic shifts were not listed and rounding affected the theoretical error.
- Evident from the text: the 16-scheme performance evaluation is theoretical rather than fully experimentally validated, and the paper itself attributes the ~3 cm theoretical–practical difference to averaging-time settings, rounding, gravity-value differences, and fiber path error.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
15 Valid · 8 Not valid · 14 Not checked · 92 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In summary, the existing methods cannot achieve the unification of global height datum with an accuracy of 1 cm, which is of great significance to develop new methods to solve this problem.”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 1. Introduction
What the sources say
- Not checked — no full text of the sourcecites [5] Sideris, 2017, Vertical datum unification for the international height reference system (IHRS), Geophys. J. Int.
- Not checked — no full text of the sourcecites [7] Zhang, P., Bao, L., Guo, D., Wu, L., Li, Q., Liu, H., Xue, Z., and Li, Z. (2020). Estimation of Vertical Datum Parameters Using the GBVP Approach Based on the Combined Global Geopotential Models. Remote Sens., 12. source
- Partly supportedcites [8] Wu, 2019, Clock networks for height system unification: A simulation study, Geophys. J. Int. sourceExperimental — accuracy not yet measured
The Introduction (pp. 1594–1595) reports that classical geodetic levelling has absolute accuracy of up to ±2 m relative to a global datum and describes limitations of other unification approaches. It does not establish that every existing method is unable to achieve 1 cm accuracy; the paper’s explicit 1 cm finding concerns the accuracy of current clocks in its simulations (p. 1606). (LLM, conf=0.85)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Both Clock 1 and 2 are 40 Ca + optical clocks developed by APM [18,36].”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 5.1. Clocks and OFFT Systems
What the sources say
- Not checked — no full text of the sourcecites [18] Huang, 2022, Liquid-Nitrogen-Cooled Ca+ Optical Clock with Systematic Uncertainty of 3 × 10 −18, Phys. Rev. Appl. source
- Partly supportedcites [36] Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., and Huang, X.-R. (2022). Laboratory demonstration of geopotential measurement using transportable optical clocks. Chin. Phys. B, in press. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says that TOC-729-1, TOC-729-2, and TOC-729-3 are transportable ⁴⁰Ca⁺ optical clocks developed in Wuhan, supporting the clock type for 1 and 2. Our copy does not identify APM as their developer; the Experimental details also clarify that this paper's measurement used clocks 1 and 3, not 1 and 2. (LLM, conf=0.82)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The measurement systematic error of the optical clock mainly includes eleven items, including blackbody radiation (BBR), second-order Doppler shift, and so on, which should be evaluated before application [16,18,36].”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 3. Error Sources of Chronometric Leveling
What the sources say
- Partly supportedcites [16] Brewer, 2019, Al-27(+) Quantum-Logic Clock with a Systematic Uncertainty below 10(−18), Phys. Rev. Lett. sourceExperimental — accuracy not yet measured
Our copy of King et al. (PRL 123, 033201) supports the substance of the attribution: it states that 'Systematic frequency shifts and associated uncertainties are listed in Table I' (p. 2) and it explicitly evaluates blackbody radiation (BBR) shift, Δν/ν = -(30.5 ± 4.2) × 10^-19 (p. 4; Supplement 'BBR Summary', p. 14), and second-order Doppler / time-dilation shifts from excess micromotion and secular motion (p. 2, p. 3, Supplement 'SECULAR MOTION', pp. 11-12), alongside first-order Doppler (p. 9), quadratic Zeeman (p. 3) and collisional shifts (p. 4). What our copy does not support is the specific count of 'eleven items': Table I's caption is present (p. 4) but its rows are not decoded in our text, and no passage enumerates or totals the number of systematic terms. The claim is also framed generically for 'the optical clock', whereas the source's budget is for this single 27Al+ quantum-logic clock. (LLM, conf=0.72)
- Not checked — no full text of the sourcecites [18] Huang, 2022, Liquid-Nitrogen-Cooled Ca+ Optical Clock with Systematic Uncertainty of 3 × 10 −18, Phys. Rev. Appl. source
- Partly supportedcites [36] Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., and Huang, X.-R. (2022). Laboratory demonstration of geopotential measurement using transportable optical clocks. Chin. Phys. B, in press. sourceExperimental — accuracy not yet measured
Section 3.2 says systematic frequency-shift uncertainties must be evaluated, and Table 2 lists both blackbody-radiation and second-order Doppler effects. But Table 2 lists 15 individual effects, not eleven, so the claimed count is not supported. (LLM, conf=0.89)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The former is a miniaturized transportable optical clock, and the systematic error reaches 1.3 × 10 -17 .”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 5.1. Clocks and OFFT Systems
What the sources say
- Not checked — no full text of the sourcecites [18] Huang, 2022, Liquid-Nitrogen-Cooled Ca+ Optical Clock with Systematic Uncertainty of 3 × 10 −18, Phys. Rev. Appl. source
- Supportedcites [36] Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., and Huang, X.-R. (2022). Laboratory demonstration of geopotential measurement using transportable optical clocks. Chin. Phys. B, in press. source
The Introduction describes TOC-729-1 as a transportable optical clock built with a modular, integrated design. Section 3.2 reports its total systematic uncertainty as 1.3 × 10^-17; the paper calls this an uncertainty rather than a measured systematic error. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In addition, the frequency statistical error of the optical clock may be caused by outliers, drift, and noise characteristic of the output frequency [37].”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 3. Error Sources of Chronometric Leveling
What the sources say
- Partly supportedcites [37] Galleani, 2003, A mathematical model for the atomic clock error, Metrologia sourceExperimental — accuracy not yet measured
Section 3.1, “Clock noises,” describes frequency drift and random noises affecting atomic-clock signals. It does not identify outliers as a cause of frequency error or specifically address optical clocks. (LLM, conf=0.86)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
68 more claims · 1 with their cited sources checked
Create a free account to see all 129 claims and to verify the 2 references still open.
- It may state two separate claims as one. 39
- Probably not a substantial claim. 24
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“If the frequency ratio of optical clocks changes by 1.0 × 10 -18 , the corresponding height difference is about 9.1 mm”
§ Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks > 2. Principle of Chronometric Leveling
Reported 0.0091 · recomputed 0.91
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Research works printed but not linked: 2
- Hofmann-Wellenhof, B., and Moritz, H. (2006). Physical Geodesy, Springer Science & Business Media.
- Ely, T.A., Seubert, J., Prestage, J., Tjoelker, R., and Burt, E. (2019, January 11–13). Deep Space Atomic Clock Mission Overview. Proceedings of the AAS/AIAA, Astrodynamics Specialist Conference, Portland, ME, USA.
Cited by
Geopotential Difference Measurement Using Two Transportable Optical Clocks’ Frequency Comparisons
Liu, D., Wu, L. F., Xiong, C., & Bao, L. (2024) · Remote Sensing · doi:10.3390/rs16132462 · Cited by 12
Self-citationМареев, А. В., & Гиенко, Е. Г. (2025) · Geodesy and Cartography · doi:10.22389/0016-7126-2025-1024-10-12-20
Metadata
- Authors
- Xiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P.
- Affiliations
- University of Chinese Academy of Sciences (CN)
- State Key Laboratory of Geodesy and Earth's Dynamics (CN)
- Corresponding author
- Wu, Lin
- Venue
- Remote Sensing
- Publisher
- MDPI AG
- Published
- 2022-08-23
- Volume
- 14
- Issue
- 17
- Pages
- 4141
- ISSN
- 2072-4292 (ISSN-L)
- OpenAlex
- W4292869330
- Cited by
- 3
- References
- 60
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1
- FWCI
- 0.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Remote Sensing (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (42174102, ZDBS-LY-DQC028)
- Basic Frontier Science Research Program of Chinese Academy of Sciences (42174102, ZDBS-LY-DQC028)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Engineering › Aerospace Engineering › GNSS positioning and interference
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Keywords
- optical clocks, gravitational redshift, height measurement accuracy, error model, frequency comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks. https://app.cochat.ai/papers/10.3390/rs14174141
- The paper
- Xiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P. (2022). Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks. Remote Sensing. https://doi.org/10.3390/rs14174141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.