An experiment for the direct determination of the g-factor of a single proton in a Penning trap
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
A new apparatus has been designed that aims at a direct precision measurement of the g -factor of a single isolated proton or antiproton in a Penning trap. We present a thorough discussion on the trap design and a method for the experimental trap optimization using a single stored proton. A first attempt at the g -factor determination has been made in a section of the trap with a magnetic bottle. The Larmor frequency of the proton has been measured with a relative uncertainty of 1.8 × 10 −6 and the magnetic moment has been determined with a relative uncertainty of 8.9 × 10 −6 . A g -factor of 5.585 696(50) has been obtained, which is in excellent agreement with previous measurements and predictions. Future experiments shall drive the spin-flip transition in a section of the trap with a homogeneous magnetic field. This has the potential to improve the precision of the measured g -factor of the proton and the antiproton by several orders of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


























Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367 · cited 7×
“4), as demonstrated in [25].”
BackgroundMethodResultInfluentialThe Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
New measurement of the electron magnetic moment and the fine structure constant
Hanneke, D., Fogwell, S., & Gabrielse, G. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.120801 · Cited by 1,138
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 860 · cited 1×
“Furthermore, Penning traps are crucial in the field of high-accuracy mass spectrometry [5–8].”
BackgroundSelf-citationRecent trends in the determination of nuclear masses
Lunney, D., Pearson, J. M., & Thibault, C. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1021 · Cited by 759
New high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288 · cited 3×
“By means of a proper choice of the trap geometry and tuning ratio, C4 and C6 can be eliminated simultaneously, thus providing compensation of the potential in the lowest order [34, 35].”
BackgroundThousandfold improvement in the measured antiproton mass
Gabrielse, G., Fei, X., Orozco, L., Tjoelker, R., Haas, J., Kalinowsky, H., Trainor, T., & Kells, W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.1317 · Cited by 275 · cited 1×
“When cooled down to cryogenic temperatures a vacuum pressure below 10−14 mbar can be achieved due to cryopumping [26, 27], which allows for storage times of the order of months.”
Background
Research works printed but not linked: 4
- [27]27. Hermanspahn N H 1999 Das magnetische Moment des gebundenen Elektrons in wasserstoffartigem Kohlenstoff (C 5+ ) Dissertation Johannes Gutenberg-Universität Mainz
- [33]33. Bozorth R M 1993 Ferromagnetism (New York: Wiley-IEEE Press)
- [38]38. Verdú J 2003 Ultrapräzise Messung des elektronischen g-Faktors in wasserstoffähnlichem Sauerstoff Dissertation Johannes Gutenberg-Universität Mainz
- [39]39. Rodegheri C C 2012 Speicherung und Kühlung eines einzelnen Protons in einer Penning-Falle zur Bestimmung seines g-Faktors Dissertation Johannes Gutenberg-Universität Mainz (in preparation)
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA Recommended Values of the Fundamental Physical Constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.4954402 · Cited by 252
Double-trap measurement of the proton magnetic moment at 0.3 parts per billion precision
Schneider, G. L., Mooser, A. H., Bohman, M., Schön, N., Harrington, J. A., Higuchi, T., Nagahama, H., Sellner, S., Smorra, C., Blaum, K., et al. (2017) · Science · doi:10.1126/science.aan0207 · Cited by 158
Self-citationOne-Particle Measurement of the Antiproton Magnetic Moment
DiSciacca, J., Marshall, M., Marable, K., Gabrielse, G., Ettenauer, S., Tardiff, E., Kalra, R., Fitzakerley, D. W., George, M. C., Hessels, E. A., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.130801 · Cited by 90
BASE – The Baryon Antibaryon Symmetry Experiment
Smorra, C., Blaum, K., Bojtar, L., Borchert, M., Franke, K. A., Higuchi, T., Leefer, N., Nagahama, H., Matsuda, Y., Mooser, A., et al. (2015) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2015-02607-4 · Cited by 82
Self-citationPhysics at CERN’s Antiproton Decelerator
Hori, M., & Walz, J. (2013) · Progress in Particle and Nuclear Physics · doi:10.1016/j.ppnp.2013.02.004 · Cited by 99
Self-citationDirect high-precision measurement of the magnetic moment of the proton
Mooser, A., Ulmer, S., Blaum, K., Franke, K., Kracke, H., Leiteritz, C., Quint, W., Rodegheri, C. C., Smorra, C., & Walz, J. (2014) · Nature · doi:10.1038/nature13388 · Cited by 96
“of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in units of the nuclear magneton . This measurement ( ) outperforms previous Penning trap measurements [4,5] in terms of precision by a factor of about 760. It improves the precision of the forty year old indirect measurem…”
BackgroundMethodInfluentialSelf-citationResolution of Single Spin Flips of a Single Proton
Mooser, A. H., Kracke, H., Blaum, K., Bräuninger, S. A., Franke, K., Leiteritz, C., Quint, W., Rodegheri, C. C., Ulmer, S., & Walz, J. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.140405 · Cited by 65
Self-citationPhysics at CERN's Antiproton Decelerator
Hori, M., & Walz, J. (2013) · MPG.PuRe (Max Planck Society) · Cited by 54
Self-citationUlmer, S., Blaum, K., Kracke, H., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2013) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2012.12.071 · Cited by 54
Self-citationA reservoir trap for antiprotons
Smorra, C., Mooser, A. H., Franke, K., Nagahama, H., Schneider, G. L., Higuchi, T., Gorp, S. V., Blaum, K., Matsuda, Y., Quint, W., et al. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2015.08.007 · Cited by 45
Self-citationDemonstration of the double Penning Trap technique with a single proton
Mooser, A. H., Bräuninger, S. A., Franke, K., Kracke, H., Leiteritz, C., Rodegheri, C. C., Nagahama, H., Schneider, G. L., Smorra, C., Blaum, K., et al. (2013) · Physics Letters B · doi:10.1016/j.physletb.2013.05.012 · Cited by 38
Self-citationMeasurement of Ultralow Heating Rates of a Single Antiproton in a Cryogenic Penning Trap
Borchert, M. J., Blessing, P. E., Devlin, J. A., Harrington, J. A., Higuchi, T., Morgner, J., Smorra, C., Wursten, E., Bohman, M., Wiesinger, M., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.043201 · Cited by 35
Self-citationSplitting methods for time integration of trajectories in combined electric and magnetic fields
Knapp, C., Kendl, A., Koskela, A., & Ostermann, A. (2015) · Physical Review E · doi:10.1103/physreve.92.063310 · Cited by 29
Observation of individual spin quantum transitions of a single antiproton
Smorra, C., Mooser, A. H., Besirli, M., Bohman, M., Borchert, M. J., Harrington, J. A., Higuchi, T., Nagahama, H., Schneider, G. L., Sellner, S., et al. (2017) · Physics Letters B · doi:10.1016/j.physletb.2017.03.024 · Cited by 26
Self-citationSearching for new physics through atomic, molecular and optical precision measurements
Orzel, C. (2012) · Physica Scripta · doi:10.1088/0031-8949/86/06/068101 · Cited by 24
CPT symmetry tests with cold and antihydrogen
Yamazaki, Y., & Ulmer, S. (2013) · Annalen der Physik · doi:10.1002/andp.201300060 · Cited by 21
Self-citationResolving an Individual One-Proton Spin Flip to Determine a Proton Spin State
DiSciacca, J., Marshall, M., Marable, K., & Gabrielse, G. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.140406 · Cited by 21
Precision Measurements of the Fundamental Properties of the Proton and Antiproton
Smorra, C., & Mooser, A. H. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1412/3/032001 · Cited by 19
“These techniques were implemented in two experiments: the proton g-factor experiment at the University of Mainz (BASE-Mainz) [37], and the BASE experiment at the antiproton decelerator of CERN [38].”
MethodSelf-citationInertial and gravitational effects on a geonium atom
Ito, A. (2021) · Classical and Quantum Gravity · doi:10.1088/1361-6382/ac1be9 · Cited by 14
Towards a high-precision measurement of the antiproton magnetic moment
Smorra, C., Blaum, K., Franke, K., Matsuda, Y., Mooser, A. H., Nagahama, H., Ospelkaus, C., Quint, W., Schneider, G. L., Gorp, S. V., et al. (2014) · Hyperfine Interactions · doi:10.1007/s10751-014-1018-7 · Cited by 11
Self-citationThe magnetic moments of the proton and the antiproton
Ulmer, S., Mooser, A. H., Blaum, K., Braeuninger, S., Franke, K., Kracke, H., Leiteritz, C., Matsuda, Y., Nagahama, H., Ospelkaus, C., et al. (2014) · Journal of Physics Conference Series · doi:10.1088/1742-6596/488/1/012033 · Cited by 8
Self-citationDesign of a dynamically orthogonalized Penning trap with higher order anharmonicity compensation
Sikdar, A. K., Ray, A., Das, P., & Reza, A. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.01.062 · Cited by 7
The Magnetic Moments of the Proton and the Antiproton
Ulmer, S., & Smorra, C. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_5 · Cited by 7
Self-citationA Novel Penning‐Trap Design for the High‐Precision Measurement of the 3He2 + Nuclear Magnetic Moment
Schneider, A., Mooser, A. H., Rischka, A., Blaum, K., Ulmer, S., & Walz, J. (2019) · Annalen der Physik · doi:10.1002/andp.201800485 · Cited by 7
Self-citationStudy of adaptive symplectic methods for simulating charged particle dynamics
Shi, Y., Sun, Y., Wang, Y., & Liu, J. (2019) · Journal of Computational Dynamics · doi:10.3934/jcd.2019022 · Cited by 6
Precision experiments and fundamental physics at low energies – Part I
Blaum, K., Müller, H., & Severijns, N. (2013) · Annalen der Physik · doi:10.1002/andp.201300729 · Cited by 5
Self-citationProperties of a cylindrical Penning trap with conical endcap openings
Kumar, S., Quint, W., Ringleb, S., Safvan, C. P., Stallkamp, N., Stöhlker, T., & Vogel, M. (2019) · Physica Scripta · doi:10.1088/1402-4896/ab0aaa · Cited by 4
Self-citationZeeman Spectroscopy in Penning Traps
Werth, G., Sturm, S., & Blaum, K. (2018) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2018.02.004 · Cited by 4
Self-citationDas magnetische Moment des Protons: Erste direkte Hochpräzisionsmessung
Mooser, A. H., Smorra, C., & Ulmer, S. (2015) · Physik in unserer Zeit · doi:10.1002/piuz.201401384 · Cited by 3
Self-citationDetection of individual spin transitions of a single proton confined in a cryogenic Penning trap
Kracke, H. (2013) · Gutenberg Open Science · doi:10.25358/openscience-4409 · Cited by 4
Self-citationTowards Laser Cooling of Beryllium Ions at the Alphatrap Experiment
Kraemer, S. (2017) · MPG.PuRe (Max Planck Society) · Cited by 3
Quantisation of the elliptical Penning trap
Crimin, F., Garraway, B. M., & Verdú, J. L. (2021) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/abfeda · Cited by 1
Application of the Continuous Stern Gerlach Effect: Magnetic Moments
Vogel, M. (2018) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-319-76264-7_22 · Cited by 1
Kostelecký, V. A. (2014) · Nature · doi:10.1038/509571a
Quantum theory of the Penning trap : an exploration of the low temperature regime
Crimin, F. (2018) · Sussex Research Online (University of Sussex)
Ulmer, S., Walz, J., Schneider, G. L., Blaum, K., Mooser, A. H., Borchert, M. J., Ospelkaus, C., Smorra, C., Quint, W., Higuchi, T., et al. (2016) · CERN Document Server (European Organization for Nuclear Research)
Self-citationDirect measurement of the proton magnetic moment
Mooser, A. H., Kracke, H., Leiteritz, C., Blaum, K., Bräuninger, S. A., Walz, J., Quint, W., Ulmer, S., & Rodegheri, C. C. (2013) · GSI Repository (German Federal Government)
Self-citationUlmer, S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05625-3_10
Self-citationHirstoaga, S. A. (2024) · SIAM Journal on Scientific Computing · doi:10.1137/23m158351x
Application of the Continuous Stern Gerlach Effect: Magnetic Moments
Vogel, M. (2024) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-031-55420-9_24
(2013) · GSI Repository (German Federal Government)
2012 Progress Report by the Antihydrogen TRAP Collaboration (ATRAP)
Gabrielse, G. (2013) · CERN Document Server (European Organization for Nuclear Research)
Rodegheri, C. C. (2014) · Gutenberg Open Science · doi:10.25358/openscience-2864
Self-citation
Metadata
- Authors
- Rodegheri, C. C., Blaum, K., Kracke, H., Kreim, S., Mooser, A., Quint, W., Ulmer, S., & Walz, J.
- Affiliations
- Johannes Gutenberg University Mainz (DE)
- Heidelberg University (DE)
- GSI Helmholtz Centre for Heavy Ion Research (DE)
- Max Planck Institute for Nuclear Physics (DE)
- Corresponding author
- Rodegheri, C C
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2012-06-12
- Volume
- 14
- Issue
- 6
- Pages
- 063011
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W2096697046
- Semantic Scholar
- dfb6b3f07470f191e7cd1bfa5bf2233a007dcce8
- Cited by
- 37
- References
- 51
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- New Journal of Physics (publishedVersion, cc-by)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- European Commission
- Deutsche Forschungsgemeinschaft
- Bundesministerium für Bildung und Forschung
- Max-Planck-Gesellschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle physics theoretical and experimental studies
- Keywords
- proton g-factor, Penning trap, antiprotons, magnetic moment, Larmor frequency, magnetic bottle, spin-flip transitions, uniform magnetic field
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.