Surface treatments for controlling corrosion rate of biodegradable Mg and Mg-based alloy implants
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Due to their excellent biodegradability characteristics, Mg and Mg-based alloys have become an emerging material in biomedical implants, notably for repair of bone as well as coronary arterial stents. However, the main problem with Mg-based alloys is their rapid corrosion in aggressive environments such as human bodily fluids. Previously, many approaches such as control of alloying materials, composition and surface treatments, have been attempted to regulate the corrosion rate. This article presents a comprehensive review of recent research focusing on surface treatment techniques utilised to control the corrosion rate and surface integrity of Mg-based alloys in both in vitro and in vivo environments. Surface treatments generally involve the controlled deposition of thin film coatings using various coating processes, and mechanical surfacing such as machining, deep rolling or low plasticity burnishing. The aim is to either make a protective thin layer of a material or to change the micro-structure and mechanical properties at the surface and sub-surface levels, which will prevent rapid corrosion and thus delay the degradation of the alloys. We have organised the review of past works on coatings by categorising the coatings into two classes—conversion and deposition coatings—while works on mechanical treatments are reviewed based on the tool-based processes which affect the sub-surface microstructure and mechanical properties of the material. Various types of coatings and their processing techniques under two classes of coating and mechanical treatment approaches have been analysed and discussed to investigate their impact on the corrosion performance, biomechanical integrity, biocompatibility and cell viability. Potential challenges and future directions in designing and developing the improved biodegradable Mg/Mg-based alloy implants were addressed and discussed. The literature reveals that no solutions are yet complete and hence new and innovative approaches are required to leverage the benefit of Mg-based alloys. Hybrid treatments combining innovative biomimetic coating and mechanical processing would be regarded as a potentially promising way to tackle the corrosion problem. Synergetic cutting-burnishing integrated with cryogenic cooling may be another encouraging approach in this regard. More studies focusing on rigorous testing, evaluation and characterisation are needed to assess the efficacy of the methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Understanding Magnesium Corrosion—A Framework for Improved Alloy Performance
Song, G., & Atrens, A. (2003) · Advanced Engineering Materials · doi:10.1002/adem.200310405 · Cited by 2,056 · cited 1×
“For instance, when Mg is exposed to an aqueous (H2O) solution, the following reaction takes place [46]”
BackgroundThe history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Biomedical coatings on magnesium alloys – A review
Hornberger, H., Virtanen, S., & Boccaccini, A. R. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.012 · Cited by 1,273 · cited 4×
“It is reported that for a corrosion test in a given electrolytic solution such as SBF, the reduction in corrosion rate is varied [48] and this indicates that the corrosion rate is controllable.”
BackgroundMethodInfluentialErbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Kirkland, N. T., Birbilis, N., & Staiger, M. P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.014 · Cited by 856 · cited 1×
“Interestingly, Mg2Ca, as an intermetallic phase, was found to be electrochemically more active (representing the anodic role) than the alphaphase and possess the same crystal structure as pure Mg [42],”
BackgroundProgress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600 · cited 1×
“and need further surgical intervention in case of potential complications such as damage to the blood vessel [28].”
BackgroundPeuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569 · cited 2×
“Permanent metallic implants prevent the normal growth of the tissue of the artery, which is critical for children with implants in their bodies requiring stents to last for a lifetime [30].”
BackgroundIOF Fracture Working Group, Åkesson, K., Marsh, D., Mitchell, P. J., McLellan, A. R., Stenmark, J., Pierroz, D. D., Kyer, C., & Cooper, C. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2348-z · Cited by 521
Li, L., Gao, J., & Wang, Y. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.01.004 · Cited by 441 · cited 1×
“Gu et al [52], Li et al [53], and Zhu et al [54] studied the effect of alkaline heat treatments on Mg–Ca alloys.”
BackgroundDrug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428 · cited 3×
“Di Mario et al [37] studied the Lekton Magic coronary stent (Biotronik, Bulach, Switzerland) made of WE43 magnesium alloy in the coronary artery of 33 minipigs.”
BackgroundElectrodeposition of Ca–P coatings on biodegradable Mg alloy: In vitro biomineralization behavior☆
Song, Y., Zhang, S., Li, J., Zhao, C., & Zhang, X. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.020 · Cited by 385 · cited 4×
“For instance, Song et al [55] developed hydroxyapatite (HA, Ca10(PO4)6(OH)2) and fluoridated hydroxyapatite (FHA, Ca5(PO4)3(OH)1−xFx) coatings on a Mg–Zn alloy and assessed their corrosion performance in simulated body fluid (SBF).”
BackgroundInfluentialStefanini, G. G., Byrne, R. A., Serruys, P. W., de Waha, A., Meier, B., Massberg, S., Juni, P., Schomig, A., Windecker, S., & Kastrati, A. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs086 · Cited by 384 · cited 1×
“A hybrid technique combining mechanical processing and coating, along with drug eluting polymeric layers [121], would be a promising means to control the corrosion rate, hence maintaining the desired mechanical integrity of the implants as they heal and remodel adequately.”
MethodCorrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg–Ca alloy
Gu, X. N., Li, N., Zhou, W. R., Zheng, Y. F., Zhao, X., Cai, Q. Z., & Ruan, L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.034 · Cited by 383 · cited 1×
“For instance, Gu et al [75] prepared the electrolyte from the solution of 10 g L sodium silicate with 3.”
MethodWang, H. X., Guan, S. K., Wang, X., Ren, C. X., & Wang, L. G. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.009 · Cited by 359 · cited 1×
“Using this technique, Wang et al [77] developed Cadeficient HA (Ca-def HA) coating on a Mg–Zn–Ca alloy and found that both corrosion resistance and mechanical properties such as ultimate tensile strength (and time to fracture) were improved by the Ca-def HA coatings.”
MethodA review of plasma-assisted methods for calcium phosphate-based coatings fabrication
Surmenev, R. A. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2011.11.002 · Cited by 332
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Wen, C., Guan, S., Peng, L., Ren, C., Wang, X., & Hu, Z. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2008.09.078 · Cited by 312
Ormiston, J. A., & Serruys, P. W. S. (2009) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.859173 · Cited by 305
Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B. (2005) · Journal of Endovascular Therapy · doi:10.1583/04-1349r.1 · Cited by 275 · cited 2×
“Peeters et al [38] further investigated Lekton Magic coronary stents implanted in humans for treatment of lower limb ischemia of 20 patients, and reported that no symptoms of allergic or toxic reactions to the Mgbased stents were found.”
Biodegradable Orthopedic Magnesium-Calcium (MgCa) Alloys, Processing, and Corrosion Performance
Salahshoor, M., & Guo, Y. (2012) · Materials · doi:10.3390/ma5010135 · Cited by 254
A study on alkaline heat treated Mg–Ca alloy for the control of the biocorrosion rate
Gu, X. N., Zheng, W., Cheng, Y., & Zheng, Y. F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.048 · Cited by 226 · cited 4×
“Gu et al [52], Li et al [53], and Zhu et al [54] studied the effect of alkaline heat treatments on Mg–Ca alloys.”
BackgroundMethodInfluentialZhao, Y., Jamesh, M. I., Li, W. K., Wu, G., Wang, C., Zheng, Y., Yeung, K. W. K., & Chu, P. K. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.012 · Cited by 220
Surface modification of biodegradable magnesium and its alloys for biomedical applications
Tian, P., & Liu, X. (2015) · Regenerative Biomaterials · doi:10.1093/rb/rbu013 · Cited by 218 · cited 6×
“Furthermore, the detailed description of different types of ion implantation can be found in a comprehensive review performed by Tian and Liu [69].”
BackgroundInfluentialFarraro, K. F., Kim, K. E., Woo, S. L.-Y., Flowers, J. R., & McCullough, M. B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.12.003 · Cited by 214
Growth and characterization of Mg(OH)2 film on magnesium alloy AZ31
Zhu, Y., Wu, G., Zhang, Y.-H., & Zhao, Q. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.02.017 · Cited by 210 · cited 4×
“Gu et al [52], Li et al [53], and Zhu et al [54] studied the effect of alkaline heat treatments on Mg–Ca alloys.”
BackgroundMethodInfluentialCha, P.-R., Han, H.-S., Yang, G.-F., Kim, Y.-C., Hong, K.-H., Lee, S.-C., Jung, J.-Y., Ahn, J.-P., Kim, Y.-Y., Cho, S.-Y., et al. (2013) · Scientific Reports · doi:10.1038/srep02367 · Cited by 206 · cited 2×
“Reprinted by permission from Macmillan Publishers Ltd: [22], copyright 2013.”
BackgroundMethodFluoride treatment and in vitro corrosion behavior of an AZ31B magnesium alloy
Yan, T., Tan, L., Xiong, D., Liu, X., Zhang, B., & Yang, K. (2010) · Materials Science and Engineering: C · doi:10.1016/j.msec.2010.03.007 · Cited by 198 · cited 1×
“Similar effects of fluoride coatings on Mg-alloys in terms of improving corrosion and mechanical integrity performance were examined and reported by other researchers [50].”
BackgroundA bioactive titanium foam scaffold for bone repair
Spoerke, E. D., Murray, N. G., Li, H., Brinson, L. C., Dunand, D. C., & Stupp, S. I. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.04.005 · Cited by 197 · cited 1×
“which is the reduction of load borne by the bone, by the implant which results in osteopenia [8].”
BackgroundLi, J., Song, Y., Zhang, S., Zhao, C., Zhang, F., Zhang, X., Cao, L., Fan, Q., & Tang, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.023 · Cited by 185
Bosiers, M., & On Behalf of the AMS INSIGHT Investigators (2008) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-008-9472-8 · Cited by 173
Ishizaki, T., & Sakamoto, M. (2011) · Langmuir · doi:10.1021/la1051029 · Cited by 169 · cited 1×
“and facilitated the cell growth surrounding the implant [49, 69, 71].”
BackgroundKang, S.-H., Park, K. W., Kang, D.-Y., Lim, W.-H., Park, K. T., Han, J.-K., Kang, H.-J., Koo, B.-K., Oh, B.-H., Park, Y.-B., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht570 · Cited by 168 · cited 1×
“Polymeric stents are not able to provide sufficient mechanical strength to hold the stent open for a certain time as the blood vessel regains its original capability [27].”
BackgroundSurface prestressing to improve fatigue strength of components by laser shot peening
Hammersley, G., Hackel, L. A., & Harris, F. (2000) · Optics and Lasers in Engineering · doi:10.1016/s0143-8166(00)00083-x · Cited by 164
Thomann, M., Krause, C., Angrisani, N., Bormann, D., Hassel, T., Windhagen, H. J., & Meyer‐Lindenberg, A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32639 · Cited by 153
Injury in the United States; 2007 chartbook
Bergen, G., Chen, L., & Warner, M. (2008) · Cited by 118
Liu, C., Xin, Y., Tian, X., & Chu, P. K.-H. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.05.048 · Cited by 115 · cited 2×
“The mechanism for improved corrosion resistance is ascribed to the formation of intermixed layer consisting of an outer oxide layer (of MgO or Mg(OH)2), an intermediate metallic layer and a bottom layer rich in metallic elements [85].”
BackgroundMethodCui, W., Beniash, E., Gawalt, E. S., Xu, Z., & Sfeir, C. S. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.031 · Cited by 115 · cited 5×
“variable and often lack the bioactive properties necessary for controlling cellular behaviour [90].”
BackgroundInfluentialThomann, M., Krause, C., Bormann, D., von der Höh, N., Windhagen, H. J., & Meyer‐Lindenberg, A. (2009) · Materialwissenschaft und Werkstofftechnik · doi:10.1002/mawe.200800412 · Cited by 112
Fluoride Conversion Coating on Biodegradable AZ31B Magnesium Alloy
Yan, T., Tan, L., Zhang, B., & Yang, K. (2014) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2013.12.015 · Cited by 109 · cited 2×
“(a) Scanning electron microscopy (SEM) image of fluoride coated AZ31 sample (b) electrochemical impedance spectroscopy (EIS) spectra of bare and fluoride coated sample in simulated blood plasma (c) surface and cross-sectional morphologies of fluoride coated sample in simulated blood plasma at different time intervals…”
BackgroundАнатольевич, С. Р., Surmeneva, M. A., Evdokimov, K. E., Pichugin, V. F., Peitsch, T., & Epple, M. (2011) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2010.12.039 · Cited by 104
Mhaede, M., Pastorek, F., & Hadzima, B. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.023 · Cited by 101
Research on Mg-Zn-Ca Alloy as Degradable Biomaterial
Zhang, B. P., Wang, Y., & Geng, L. (2011) · InTech eBooks · doi:10.5772/23929 · Cited by 98 · cited 6×
“0 license) and (b) Mg–Zn alloying (reproduced from [23], copyright 2011 Zhang B P, Wang Y, Geng L.”
BackgroundInfluentialIn vitro study of nanostructured diopside coating on Mg alloy orthopedic implants
Razavi, M., Fathi, M., Savabi, O., Vashaee, D., & Tayebi, L. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.04.039 · Cited by 97 · cited 3×
“Razavi et al [63] also studied akermanite (Ca2MgSi2O7) coating on Mg alloys and found a similar improvement by the coating in terms of reducing the ecorrosion rate and preserving biocompatibility.”
MethodToba, Y., Kajita, Y., Masuyama, R., Takada, Y., Suzuki, K., & Aoe, S. (2000) · Journal of Nutrition · doi:10.1093/jn/130.2.216 · Cited by 94 · cited 1×
“Mg ions facilitate metabolic reactions and various biological mechanisms [12].”
BackgroundCorrosion behaviors in physiological solution of cerium conversion coatings on AZ31 magnesium alloy
Cui, X., Yang, Y., Liu, E., Jin, G. D., Zhong, J., & Li, Q. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.04.141 · Cited by 91 · cited 4×
“For instance, Cui et al [13] applied CaP coatings on a Mg–Ca1.”
BackgroundInfluentialCalcium phosphate coating on magnesium alloy for modification of degradation behavior
Cui, F., Yang, J., Jiao, Y., Yin, Q., Zhang, Y., & Lee, I.-S. (2008) · Frontiers of Materials Science in China · doi:10.1007/s11706-008-0024-6 · Cited by 76 · cited 5×
“As technical isolation of PP protein is quite difficult because of rapid degradation, the same authors [13] followed the principles of bio-mimicry and developed a biomimetic coating based on a peptide motif using the amino acid sequence of PP.”
MethodInfluentialEffects of tantalum ion implantation on the corrosion behavior of AZ31 magnesium alloys
Wang, X., Zeng, X., Wu, G., Yao, S., & Lai, Y. (2006) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2006.07.074 · Cited by 74 · cited 1×
“As the process only can produce a very thin layer of the modified surface, generally the corrosion resistance is not adequate in the long term [16, 80, 81].”
BackgroundLevy, G. K., & Aghion, E. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.009 · Cited by 68
Zhao, Y., Wu, G., Lu, Q., Wu, J. Y., Xu, R., Yeung, K., & Chu, P. K.-H. (2012) · Thin Solid Films · doi:10.1016/j.tsf.2012.05.046 · Cited by 66
Corrosion Protection and Surface Treatment of Magnesium Alloys Used for Orthopedic Applications
Nassif, N., & Ghayad, I. M. (2013) · Advances in Materials Science and Engineering · doi:10.1155/2013/532896 · Cited by 65 · cited 4×
“However, the CaP layer formed on Mg–Ca alloy surface was an amorphous mixed (Mg, Ca)-phosphate which can be carbonated and hydrated [45].”
BackgroundInfluentialIn vitromechanical integrity of hydroxyapatite coated magnesium alloy
Kannan, M. B., & Orr, L. (2011) · Biomedical Materials · doi:10.1088/1748-6041/6/4/045003 · Cited by 59
TiO2 Deposition on AZ31 Magnesium Alloy Using Plasma Electrolytic Oxidation
White, L., Koo, Y., Yun, Y., & Sankar, J. (2013) · Journal of Nanomaterials · doi:10.1155/2013/319437 · Cited by 58
Controllable degradation of biomedical magnesium by chromium and oxygen dual ion implantation
Xu, R., Wu, G., Yang, X., Hu, T., Lu, Q., & Chu, P. K.-H. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.04.043 · Cited by 57
Bone healing and the effect of implant surface topography on osteoconduction in hyperglycemia
Ajami, E., Mahno, E., Mendes, V. C., Bell, S., Moineddin, R., & Davies, J. E. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.09.020 · Cited by 50
Bailey, E. H. (1961) · Antarctica A Keystone in a Changing World · doi:10.3133/ofr613 · Cited by 48
Corrosion properties of oxygen plasma immersion ion implantation treated magnesium
Wan, G., Maitz, M. F., Sun, H. L., Li, P. P., & Huang, N. (2007) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2006.02.088 · Cited by 47
Biodegradable magnesium coronary stents: material, design and fabrication
Demir, A. G., Previtali, B., Ge, Q., Vedani, M., Wu, W. G., Migliavacca, F., Petrini, L., Biffi, C. A., & Bestetti, M. (2013) · International Journal of Computer Integrated Manufacturing · doi:10.1080/0951192x.2013.834475 · Cited by 47
Formation and electrochemical behavior of Al and O plasma-implanted biodegradable Mg-Y-RE alloy
Zhao, Y., Wu, G., Pan, H., Yeung, K., & Chu, P. K.-H. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2011.11.028 · Cited by 46
Biodegradable Metal Stents: A Focused Review on Materials and Clinical Studies
Purnama, A., Hermawan, H., & Mantovani, D. (2014) · Journal of Biomaterials and Tissue Engineering · doi:10.1166/jbt.2014.1263 · Cited by 46
Xu, R., Yang, X., Zhang, X., Wang, M., Li, P., Zhao, Y., Wu, G., & Chu, P. K.-H. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.09.060 · Cited by 29 · cited 2×
“(a) X-ray photoelectron spectroscopy (XPS) depth profiles of oxygen-implanted AZ31 alloy, and potentiodynamic polarization curves of unimplanted and ion-implanted alloy in SBF (reprinted from [84], copyright 2013, with permission from Elsevier), (b) XPS depth profiles of Ti-PIII&D implanted AZ91 alloy and Nyquist plot…”
BackgroundMethodvon der Höh, N., von Rechenberg, B., Bormann, D., et al. (2009) · Materialwissenschaft und Werkstofftechnik · doi:10.1002/mawe.200800378 · Cited by 26
Cited by
The role and significance of Magnesium in modern day research-A review
Prasad, S. V. S., Prasad, S. B., Verma, K., Mishra, R. K., Kumar, V., & Singh, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.05.012 · Cited by 683
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
A review of various materials for additive manufacturing: Recent trends and processing issues
Srivastava, M., Rathee, S., Patel, V., Kumar, A., & Koppad, P. G. (2022) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2022.10.015 · Cited by 311
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Cui, Y.-W., Wang, L., & Zhang, L.-C. (2024) · Progress in Materials Science · doi:10.1016/j.pmatsci.2024.101277 · Cited by 252
Metadata
- Authors
- Uddin, M. S., Hall, C., & Murphy, P.
- Venue
- Science and Technology of Advanced Materials
- Publisher
- Informa UK Limited
- Published
- 2015-10-22
- Volume
- 16
- Issue
- 5
- Pages
- 053501
- ISSN
- 1468-6996 (ISSN-L)
- 1878-5514
- OpenAlex
- W1453567852
- Cited by
- 189
- References
- 66
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.