A focused air-pulse system for optical-coherence-tomography-based measurements of tissue elasticity
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Accurate non-invasive assessment of tissue elasticity in vivo is required for early diagnostics of many tissue abnormalities. We have developed a focused air-pulse system that produces a low-pressure and short-duration air stream, which can be used to excite transient surface waves (SWs) in soft tissues. System characteristics were studied using a high-resolution analog pressure transducer to describe the excitation pressure. Results indicate that the excitation pressure provided by the air-pulse system can be easily controlled by the air source pressure, the angle of delivery, and the distance between the tissue surface and the port of the air-pulse system. Furthermore, we integrated this focused air-pulse system with phase-sensitive optical coherence tomography (PhS-OCT) to make non-contact measurements of tissue elasticity. The PhS-OCT system is used to assess the group velocity of SW propagation, which can be used to determine Young's modulus. Pilot experiments were performed on gelatin phantoms with different concentrations (10%, 12% and 14% w/w). The results demonstrate the feasibility of using this focused air-pulse system combined with PhS-OCT to estimate tissue elasticity. This easily controlled non-contact technique is potentially useful to study the biomechanical properties of ocular and other tissues in vivo .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941 · cited 1×
“For example, it is well known that tumorigenesis involves significant changes in tissue stiffness on macro- and microscopic scales [2].”
BackgroundDetermination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230 · cited 1×
“elasticity) at several scales: from ultrasonic and magnetic resonance imaging at the organ level [3, 4], to atomic force microscopy at the cellular level [5].”
BackgroundOCT elastography: imaging microscopic deformation and strain of tissue
Schmitt, J. M. (1998) · Optics Express · doi:10.1364/oe.3.000199 · Cited by 620 · cited 1×
“Recently, a method for measurements of tissue elasticity based on optical coherence tomography (OCT) imaging has been established [6].”
MethodIves, K. J. (1978) · The Scientific Basis of Flocculation · doi:10.1007/978-94-009-9938-1_8 · Cited by 463
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Li, C., Guan, G., Reif, R., Huang, Z., & Wang, R. K. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0583 · Cited by 300 · cited 1×
“Li et al used a custom-built shaker to generate an impulse mechanical stimulus which excites surface waves (SWs) in tissue [12].”
MethodElastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287 · cited 1×
“elasticity) at several scales: from ultrasonic and magnetic resonance imaging at the organ level [3, 4], to atomic force microscopy at the cellular level [5].”
BackgroundPhase-sensitive optical coherence elastography for mapping tissue microstrains in real time
Wang, R. K., Kirkpatrick, S., & Hinds, M. (2007) · Applied Physics Letters · doi:10.1063/1.2724920 · Cited by 219
Yue, X.-L., Ma, F., & Dai, Z.-F. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/4/044301 · Cited by 158
Optical micro-scale mapping of dynamic biomechanical tissue properties
Liang, X., Oldenburg, A. L., Crecea, V., Chaney, E. J., & Boppart, S. A. (2008) · Optics Express · doi:10.1364/oe.16.011052 · Cited by 148
Wang, S., Li, J., Manapuram, R. K., Menodiado, F. M., Ingram, D. R., Twa, M. D., Lazar, A. J., Lev, D. C., Pollock, R. E., & Larin, K. V. (2012) · Optics Letters · doi:10.1364/ol.37.005184 · Cited by 117 · cited 1×
“Recently, we have demonstrated that the combination of an air-pulse system and PhS-OCT can be used to differentiate soft-tissue tumors from normal tissues based on the estimation of their elasticity [22].”
BackgroundSelf-citationAcoustomotive optical coherence elastography for measuring material mechanical properties
Liang, X., Orescanin, M., Toohey, K. S., Insana, M. F., & Boppart, S. A. (2009) · Optics Letters · doi:10.1364/ol.34.002894 · Cited by 75 · cited 1×
“With a similar algorithm to quantify Young’s modulus, Liang et al utilized acoustic radiation force for internal dynamic excitation [11].”
MethodZhang, X., Qiang, B., & Greenleaf, J. F. (2010) · Ultrasonics · doi:10.1016/j.ultras.2010.07.005 · Cited by 60
Manapuram, R. K., Aglyamov, S. R., Monediado, F. M., Mashiatulla, M., Li, J., Emelianov, S., & Larin, K. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.100501 · Cited by 58
Self-citationManapuram, R. K., Baranov, S. A., Manne, V. G. R., Sudheendran, N., Mashiatulla, M., Aglyamov, S. R., Emelianov, S., & Larin, K. V. (2010) · Laser Physics Letters · doi:10.1002/lapl.201010102 · Cited by 32 · cited 1×
“Phase-resolved methods based on the processing of complex OCT signal have been developed with the capability to detect nanometer-scale changes of optical path length [7, 8].”
MethodSelf-citationThe anisotropic material constitutive models for the human cornea
Li, L.-Y., & Tighe, B. J. (2006) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.10.014 · Cited by 29 · cited 1×
“Because the cornea is a laminar anisotropic material [23], the basic algorithm used here to quantify sample elasticity may not be applicable.”
Background
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Optical coherence elastography – OCT at work in tissue biomechanics [Invited]
Larin, K. V., & Sampson, D. D. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001172 · Cited by 428
Self-citationA Review of Optical Coherence Elastography: Fundamentals, Techniques and Prospects
Kennedy, B. F., Kennedy, K. M., & Sampson, D. D. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2291445 · Cited by 334
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Self-citationOptical coherence elastography in ophthalmology
Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121720 · Cited by 228
“13) was first demonstrated to produce mechanical waves in the cornea.(50,51) This approach has certain limitations as the air-puff pulse can be very difficult to shape spatially due to spreading, resulting in low bandwidth mechanical waves.”
Background
Metadata
- Authors
- Wang, S., Larin, K. V., Li, J., Vantipalli, S., Manapuram, R. K., Aglyamov, S., Emelianov, S., & Twa, M. D.
- Venue
- Laser Physics Letters
- Publisher
- IOP Publishing
- Published
- 2013-05-20
- Volume
- 10
- Issue
- 7
- Pages
- 075605
- ISSN
- 1612-2011 (ISSN-L)
- 1612-202X
- OpenAlex
- W2018748991
- Cited by
- 181
- References
- 16
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.