CoChat

A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA

Open access
Pavlis, Nikolaos K, Weiss, Marc A · 2017 · Metrologia
Cited by 19

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

We re-evaluated the relativistic redshift correction applicable to the frequency standards at the National Institute of Standards and Technology (NIST) in Boulder, Colorado, USA, based on a precise GPS survey of three benchmarks on the roof of the building where these standards had been previously housed, and on global and regional geoid models supported by data from the GRACE and GOCE missions, including EGM2008, USGG2009, and USGG2012. We also evaluated the redshift offset based on the published NAVD88 geopotential number of the leveling benchmark Q407 located on the side of Building 1 at NIST, Boulder, Colorado, USA, after estimating the bias of the NAVD88 datum at our specific location. Based on these results, our current best estimate of the relativistic redshift correction, if frequency standards were located at the height of the leveling benchmark Q407 outside the second floor of Building 1, with respect to the EGM2008 geoid whose potential has been estimated to be , is equal to (−1798.50 ± 0.06) × 10 −16 . The corresponding value, with respect to an equipotential surface defined by the International Astronomical Union's (IAU) adopted value of , is (−1798.53 ± 0.06) × 10 −16 . These values are comparable to the value of (−1798.70 ± 0.30) × 10 −16 , estimated by Pavlis and Weiss in 2003, with respect to an equipotential surface defined by . The minus sign implies that clocks run faster in the laboratory in Boulder than a corresponding clock located on the geoid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1681-7575/aa765c

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Research works printed but not linked: 16

  1. Denker H, 2016, Paper Presented at the 1st Joint Int’l Association of Geodesy (IAG) Commission 2 and Int’l Gravity Field Service (IGFS) Symp.
  2. 10.1103/PhysRevLett.104.070802 · DOI · Paper page
  3. 10.1038/nphoton.2016.159 · DOI · Paper page
  4. 10.1103/PhysRevLett.99.153601 · DOI · Paper page
  5. 10.1103/PhysRevX.6.021016 · DOI · Paper page
  6. Altamimi Z, 2014, Presented at NASA’s Goddard Space Flight Center
  7. 10.1111/j.1365-246X.2012.05636.x · DOI · Paper page
  8. 10.1007/s10040-006-0103-7 · doi:10.1007/s10040-006-0103-7
  9. 10.1016/j.nuclphysbps.2006.12.032 · DOI · Paper page
  10. Heiskanen W A, 1967, Physical Geodesy
  11. 10.1007/978-1-4684-7098-7_14 · DOI
  12. 10.1007/978-3-642-72245-5_10 · DOI
  13. Sansò F, 2013, Lecture Notes in Earth System Sciences, 10.1007/978-3-540-74700-0 · DOI · Paper page
  14. 10.1007/BF02520477 · DOI · Paper page
  15. 10.1029/2004GL019920 · DOI · Paper page
  16. 10.1029/98EO00426 · DOI · Paper page

Cited by

See all 19

Metadata

Authors
Pavlis, N. K., & Weiss, M. A.
Venue
Metrologia
Published
2017-07-18
Volume
54
Issue
4
Pages
535-548
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2560065614
Cited by
19
References
14
FWCI
1.21
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA. https://app.cochat.ai/papers/10.1088/1681-7575/aa765c
The paper
Pavlis, N. K., & Weiss, M. A. (2017). A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA. Metrologia. https://doi.org/10.1088/1681-7575/aa765c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.