The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Open Ephys: an open-source, plugin-based platform for multichannel electrophysiology
Open accessAbstract
OBJECTIVE: Closed-loop experiments, in which causal interventions are conditioned on the state of the system under investigation, have become increasingly common in neuroscience. Such experiments can have a high degree of explanatory power, but they require a precise implementation that can be difficult to replicate across laboratories. We sought to overcome this limitation by building open-source software that makes it easier to develop and share algorithms for closed-loop control. APPROACH: We created the Open Ephys GUI, an open-source platform for multichannel electrophysiology experiments. In addition to the standard 'open-loop' visualization and recording functionality, the GUI also includes modules for delivering feedback in response to events detected in the incoming data stream. Importantly, these modules can be built and shared as plugins, which makes it possible for users to extend the functionality of the GUI through a simple API, without having to understand the inner workings of the entire application. MAIN RESULTS: In combination with low-cost, open-source hardware for amplifying and digitizing neural signals, the GUI has been used for closed-loop experiments that perturb the hippocampal theta rhythm in a phase-specific manner. SIGNIFICANCE: The Open Ephys GUI is the first widely used application for multichannel electrophysiology that leverages a plugin-based workflow. We hope that it will lower the barrier to entry for electrophysiologists who wish to incorporate real-time feedback into their research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Harris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Awake hippocampal sharp-wave ripples support spatial memory
Jadhav, S. P., Kemere, C., German, P. W., & Frank, L. M. (2012) · Science · doi:10.1126/science.1217230 · Cited by 924
Auditory closed-loop stimulation of the sleep slow oscillation enhances memory
Ngo, H.-V. V., Martinetz, T., Born, J., & Mölle, M. (2013) · Neuron · doi:10.1016/j.neuron.2013.03.006 · Cited by 885
Disruption of ripple‐associated hippocampal activity during rest impairs spatial learning in the rat
Ego‐Stengel, V., & Wilson, M. A. (2010) · Hippocampus · doi:10.1002/hipo.20707 · Cited by 842
Spike sorting for large, dense electrode arrays
Rossant, C., Kadir, S. N., Goodman, D. F. M., Schulman, J., Hunter, M. L. D., Saleem, A. B., Grosmark, A., Belluscio, M., Denfield, G. H., Ecker, A. S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4268 · Cited by 785
Gray, C. M., Maldonado, P. E., Wilson, M., & McNaughton, B. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00085-2 · Cited by 742
Kilosort: realtime spike-sorting for extracellular electrophysiology with hundreds of channels
Pachitariu, M., Steinmetz, N., Kadir, S., Carandini, M., & Kenneth D., H. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/061481 · Cited by 740
Paz, J. T., Davidson, T. J., Frechette, E. S., Delord, B., Parada, I., Peng, K., Deisseroth, K., & Huguenard, J. R. (2013) · Nature Neuroscience · doi:10.1038/nn.3269 · Cited by 566
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Closed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
Siegle, J. H., & Wilson, M. A. (2014) · eLife · doi:10.7554/elife.03061 · Cited by 271
Self-citationNeurodata Without Borders: Creating a Common Data Format for Neurophysiology
Teeters, J. L., Godfrey, K., Young, R., Dang, C., Friedsam, C., Wark, B., Asari, H., Peron, S., Li, N., Peyrache, A., et al. (2015) · Neuron · doi:10.1016/j.neuron.2015.10.025 · Cited by 195
Self-citationBuetfering, C., Allen, K., & Monyer, H. (2014) · Nature Neuroscience · doi:10.1038/nn.3696 · Cited by 160
A Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156
Bayesian decoding using unsorted spikes in the rat hippocampus
Kloosterman, F., Layton, S. P., Chen, Z. S., & Wilson, M. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.01046.2012 · Cited by 117
Upward synaptic scaling is dependent on neurotransmission rather than spiking
Fong, M., Newman, J. P., Potter, S. M., & Wenner, P. (2015) · Nature Communications · doi:10.1038/ncomms7339 · Cited by 114
Asymptotic Theory of Information-Theoretic Experimental Design
Paninski, L. (2005) · Neural Computation · doi:10.1162/0899766053723032 · Cited by 108
Population decoding of motor cortical activity using a generalized linear model with hidden states
Lawhern, V. J., Wu, W. L., Hatsopoulos, N. G., & Paninski, L. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.03.024 · Cited by 94
Rolston, J. D. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.012.2009 · Cited by 88
Newman, J. P., Zeller-Townson, R., Fong, M., Desai, S. A., Gross, R. E., & Potter, S. M. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2012.00098 · Cited by 82
From response to stimulus: adaptive sampling in sensory physiology
Benda, J., Gollisch, T., Machens, C. K., & Herz, A. V. M. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2007.07.009 · Cited by 64
Real-time Experiment Interface for biological control applications
Lin, R. J., Bettencourt, J. C., White, J. A., Christini, D. J., & Butera, R. J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627397 · Cited by 48
Current Practice in Software Development for Computational Neuroscience and How to Improve It
Gewaltig, M.-O., & Cannon, R. C. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003376 · Cited by 37
Cited by
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Survey of spiking in the mouse visual system reveals functional hierarchy
Siegle, J. H., Jia, X., Durand, S., Gale, S., Bennett, C., Graddis, N., Heller, G., Ramirez, T. K., Choi, H., Luviano, J. A., et al. (2021) · Nature · doi:10.1038/s41586-020-03171-x · Cited by 634
Self-citationSpikeInterface, a unified framework for spike sorting
Buccino, A. P., Hurwitz, C. L., Garcia, S., Magland, J., Siegle, J. H., Hurwitz, R., & Hennig, M. H. (2020) · eLife · doi:10.7554/elife.61834 · Cited by 399
Self-citationNorepinephrine-mediated slow vasomotion drives glymphatic clearance during sleep
Hauglund, N. L., Andersen, M., Tokarska, K., Radovanovic, T., Kjaerby, C., Sørensen, F. L., Bojarowska, Z., Untiet, V., Ballestero, S. B., Kolmos, M. G., et al. (2025) · Cell · doi:10.1016/j.cell.2024.11.027 · Cited by 349
Billeh, Y. N., Cai, B., Gratiy, S. L., Dai, K., Iyer, R., Gouwens, N. W., Abbasi-Asl, R., Jia, X., Siegle, J. H., Olsen, S. R., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.01.040 · Cited by 305
Self-citation
Metadata
- Authors
- Siegle, J. H., López, A. C., Patel, Y. A., Abramov, K., Ohayon, S., & Voigts, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2017-06-05
- Volume
- 14
- Issue
- 4
- Pages
- 045003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2586123043
- Cited by
- 545
- References
- 27
- FWCI
- 17.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.