CoChat

Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis

Open access
Colachis, Samuel C, Dunlap, Collin F, Annetta, Nicholas V, Tamrakar, Sanjay M, Bockbrader, Marcia A, Friedenberg, David A · 2021 · Journal of Neural Engineering
Cited by 59

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Objective. Brain-computer interfaces (BCIs) that record neural activity using intracortical microelectrode arrays (MEAs) have shown promise for mitigating disability associated with neurological injuries and disorders. While the chronic performance and failure modes of MEAs have been well studied and systematically described in non-human primates, there is far less reported about long-term MEA performance in humans. Our group has collected one of the largest neural recording datasets from a Utah MEA in a human subject, spanning over 5 years (2014–2019). Here we present both long-term signal quality and BCI performance as well as highlight several acute signal disruption events observed during the clinical study. Approach. Long-term Utah array performance was evaluated by analyzing neural signal metric trends and decoding accuracy for tasks regularly performed across 448 clinical recording sessions. For acute signal disruptions, we identify or hypothesize the root cause of the disruption, show how the disruption manifests in the collected data, and discuss potential identification and mitigation strategies for the disruption. Main results. Neural signal quality metrics deteriorated rapidly within the first year, followed by a slower decline through the remainder of the study. Nevertheless, BCI performance remained high 5 years after implantation, which is encouraging for the translational potential of this technology as an assistive device. We also present examples of unanticipated signal disruptions during chronic MEA use, which are critical to detect as BCI technology progresses toward home usage. Significance. Our work fills a gap in knowledge around long-term MEA performance in humans, providing longevity and efficacy data points to help characterize the performance of implantable neural sensors in a human population. The trial was registered on ClinicalTrials.gov (Identifier NCT01997125) and conformed to institutional requirements for the conduct of human subjects research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2552/ac1add

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 59

Metadata

Authors
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S. M., Bockbrader, M. A., & Friedenberg, D. A.
Venue
Journal of Neural Engineering
Published
2021-08-01
Volume
18
Issue
4
Pages
0460d7
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W3190821676
Cited by
59
References
25
FWCI
4.02
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis. https://app.cochat.ai/papers/10.1088/1741-2552/ac1add
The paper
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S. M., Bockbrader, M. A., & Friedenberg, D. A. (2021). Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ac1add

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.