Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Objective. Brain-computer interfaces (BCIs) that record neural activity using intracortical microelectrode arrays (MEAs) have shown promise for mitigating disability associated with neurological injuries and disorders. While the chronic performance and failure modes of MEAs have been well studied and systematically described in non-human primates, there is far less reported about long-term MEA performance in humans. Our group has collected one of the largest neural recording datasets from a Utah MEA in a human subject, spanning over 5 years (2014–2019). Here we present both long-term signal quality and BCI performance as well as highlight several acute signal disruption events observed during the clinical study. Approach. Long-term Utah array performance was evaluated by analyzing neural signal metric trends and decoding accuracy for tasks regularly performed across 448 clinical recording sessions. For acute signal disruptions, we identify or hypothesize the root cause of the disruption, show how the disruption manifests in the collected data, and discuss potential identification and mitigation strategies for the disruption. Main results. Neural signal quality metrics deteriorated rapidly within the first year, followed by a slower decline through the remainder of the study. Nevertheless, BCI performance remained high 5 years after implantation, which is encouraging for the translational potential of this technology as an assistive device. We also present examples of unanticipated signal disruptions during chronic MEA use, which are critical to detect as BCI technology progresses toward home usage. Significance. Our work fills a gap in knowledge around long-term MEA performance in humans, providing longevity and efficacy data points to help characterize the performance of implantable neural sensors in a human population. The trial was registered on ClinicalTrials.gov (Identifier NCT01997125) and conformed to institutional requirements for the conduct of human subjects research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From inflammation to sickness and depression: when the immune system subjugates the brain
Dantzer, R., O'Connor, J. C., Freund, G. G., Johnson, R. W., & Kelley, K. W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2297 · Cited by 7,395
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 3×
“In some cases, BCIs using Utah arrays have sustained high-performance for over 5 years [6, 15].”
BackgroundMethodBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 3×
“tetraplegia have successfully controlled robotic arms [6, 7], computer cursors for communication and web surfing [8, 9], and functional electrical stimulation systems to reanimate their paralyzed limbs [10, 11].”
BackgroundMethodSelf-citationBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · cited 1×
“tetraplegia have successfully controlled robotic arms [6, 7], computer cursors for communication and web surfing [8, 9], and functional electrical stimulation systems to reanimate their paralyzed limbs [10, 11].”
BackgroundIntracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Cited by
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Implantable brain machine interfaces: first-in-human studies, technology challenges and trends
Rapeaux, A. B., & Constandinou, T. G. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.001 · Cited by 119
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
Evaluation of Pneumatic Insertion Stability of Utah Slanted Electrode Arrays in Rat Sciatic Nerve
Thomas, W. M., Leber, M., Crew, J., & Warren, D. J. (2022) · 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871237 · Cited by 5
Metadata
- Authors
- Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S. M., Bockbrader, M. A., & Friedenberg, D. A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-08-01
- Volume
- 18
- Issue
- 4
- Pages
- 0460d7
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3190821676
- Cited by
- 59
- References
- 25
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis. https://app.cochat.ai/papers/10.1088/1741-2552/ac1add
- The paper
- Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S. M., Bockbrader, M. A., & Friedenberg, D. A. (2021). Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ac1add
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.