Longevity and reliability of chronic unit recordings using the Utah, intracortical multi-electrode arrays
Open accessAbstract
Objective. Microelectrode arrays are standard tools for conducting chronic electrophysiological experiments, allowing researchers to simultaneously record from large numbers of neurons. Specifically, Utah electrode arrays (UEAs) have been utilized by scientists in many species, including rodents, rhesus macaques, marmosets, and human participants. The field of clinical human brain-computer interfaces currently relies on the UEA as a number of research groups have clearance from the United States Federal Drug Administration (FDA) for this device through the investigational device exemption pathway. Despite its widespread usage in systems neuroscience, few studies have comprehensively evaluated the reliability and signal quality of the Utah array over long periods of time in a large dataset. Approach. We collected and analyzed over 6000 recorded datasets from various cortical areas spanning almost nine years of experiments, totaling 17 rhesus macaques (Macaca mulatta) and 2 human subjects, and 55 separate microelectrode Utah arrays. The scale of this dataset allowed us to evaluate the average life of these arrays, based primarily on the signal-to-noise ratio of each electrode over time. Main results. Using implants in primary motor, premotor, prefrontal, and somatosensory cortices, we found that the average lifespan of available recordings from UEAs was 622 days, although we provide several examples of these UEAs lasting over 1000 days and one up to 9 years; human implants were also shown to last longer than non-human primate implants. We also found that electrode length did not affect longevity and quality, but iridium oxide metallization on the electrode tip exhibited superior yield as compared to platinum metallization. Significance. Understanding longevity and reliability of microelectrode array recordings allows researchers to set expectations and plan experiments accordingly and maximize the amount of high-quality data gathered. Our results suggest that one can expect chronic unit recordings to last at least two years, with the possibility for arrays to last the better part of a decade.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Utah Microelectrode Array uses an external power mechanism and offers longevity with some lasting over 2.7 years and one case up to 9 years.
“Similarly, the Utah Microelectrode Array (UEA) uses an external power mechanism, offering longevity with some lasting over 2.7 years, and even one case up to 9 years (Sponheim et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Sponheim et al., 2021
The Abstract’s Main Results report several UEA recordings lasting over 1,000 days (more than 2.7 years) and one lasting up to nine years. The Methods describe cable-connected data acquisition, but do not establish the claim that the UEA uses an external power mechanism. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
D.Watson, L., & Hoefer, R. A. (2014) · Sage eBooks · doi:10.4135/9781483388007.n5 · Cited by 3,823 · see citing works
National Cancer Institute (2020) · Definitions · doi:10.32388/bz83sn · Cited by 2,981 · see citing works
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
Self-citationAn Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206 · see citing works
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 798 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642 · see citing works
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600 · see citing works
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · see citing works
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 477 · see citing works
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442 · see citing works
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · see citing works
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354 · see citing works
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350 · see citing works
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296 · see citing works
Kozai, T. D. Y., Catt, K. A., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 214 · see citing works
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 202 · see citing works
Recording from the same neurons chronically in motor cortex
Fraser, G. W., & Schwartz, A. B. (2011) · Journal of Neurophysiology · doi:10.1152/jn.01012.2010 · Cited by 149 · see citing works
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149 · see citing works
Self-citationHermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H. Y., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 134 · see citing works
Neural stimulation and recording performance in human sensorimotor cortex over 1500 days
Hughes, C. L., Flesher, S. N., Weiss, J. M., Downey, J. E., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac18ad · Cited by 93 · see citing works
Self-citationBullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65 · see citing works
Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S., Bockbrader, M. A., & Friedenberg, D. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1add · Cited by 64 · see citing works
Black, B., Kanneganti, A., Joshi‐Imre, A., Rihani, R. T., Chakraborty, B., Abbott, J., Pancrazio, J. J., & Cogan, S. F. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00181.2018 · Cited by 62 · see citing works
The marmoset as a model system for studying voluntary motor control
Walker, J. D., MacLean, J. N., & Hatsopoulos, N. G. (2016) · Developmental Neurobiology · doi:10.1002/dneu.22461 · Cited by 41 · see citing works
Self-citationDunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 29 · see citing works
Flagged first, then by citations
1 of the 30 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- [30]Polikov VS, Tresco PA, Reichert WM. Response of brain tissue to chronically implanted neural electrodes. Journal of Neuroscience Methods. 2005. 16198003
Cited by
Sorted by citations
An Accurate and Rapidly Calibrating Speech Neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2314132 · Cited by 238 · see citing works
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 130 · see citing works
Decoding motor plans using a closed-loop ultrasonic brain–machine interface
Griggs, W. S., Norman, S. L., Deffieux, T., Segura, F., Osmanski, B.-F., Chau, G., Christopoulos, V., Liu, C. Y., Tanter, M., Shapiro, M. G., et al. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01500-7 · Cited by 70 · see citing works
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49 · see citing works
Neurotechnologies to restore hand functions
Losanno, E., Mender, M. J., Chestek, C. A., Shokur, S., & Micera, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00054-4 · Cited by 42 · see citing works
Yaşar, T. B., Gombkötő, P., Vyssotski, A. L., Vavladeli, A., Lewis, C. M., Wu, B., Meienberg, L., Lundegardh, V., Helmchen, F., von der Behrens, W., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49226-9 · Cited by 31 · see citing works
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 36 · see citing works
Translational Organic Neural Interface Devices at Single Neuron Resolution
Hassan, A. R., Zhao, Z., Ferrero, J. J., Cea, C., Jastrzebska‐Perfect, P., Myers, J. C., Asman, P., Ince, N. F., McKhann, G. M., Viswanathan, A., et al. (2022) · Advanced Science · doi:10.1002/advs.202202306 · Cited by 27 · see citing works
Enhancing biocompatibility of the brain-machine interface: A review
Villa, J., Cury, J., Kessler, L., Tan, X., & Richter, C. (2024) · Bioactive Materials · doi:10.1016/j.bioactmat.2024.08.034 · Cited by 29 · see citing works
In vivo microelectrode arrays for neuroscience
Williams, N. P., Vöröslakos, M., Shi, D., Pwint, M. Y., Lanzio, V., Mao, H., Zolotavin, P., Yoon, E., Stieglitz, T., Xie, C., et al. (2025) · Nature Reviews Methods Primers · doi:10.1038/s43586-025-00399-7 · Cited by 29 · see citing works
Flexible multimaterial fibers in modern biomedical applications
Kim, J., & Jia, X. (2024) · National Science Review · doi:10.1093/nsr/nwae333 · Cited by 24 · see citing works
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21 · see citing works
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 21 · see citing works
Lo, Y. T., Lim, M. J. R., Kok, C. Y., Wang, S., Blok, S. Z., Ang, T. Y., Ng, V. Y. P., Rao, J. P., & Chua, K. S. G. (2024) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2024.04.001 · Cited by 21 · see citing works
Emerging Penetrating Neural Electrodes: In Pursuit of Large Scale and Longevity
Luan, L., Yin, R., Zhu, H., & Xie, C. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-090622-050507 · Cited by 19 · see citing works
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 20 · see citing works
An accurate and rapidly calibrating speech neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2023) · doi:10.1101/2023.12.26.23300110 · Cited by 244 · see citing works
Recording of pig neuronal activity in the comparative context of the awake human brain
Dobariya, A., Ahmadieh, T. Y. E., Good, L. B., Hernandez-Reynoso, A. G., Jakkamsetti, V., Brown, R., Dunbar, M. L., Ding, K., Luna, J., Kallem, R. R., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-19688-2 · Cited by 16 · see citing works
Compact deep neural network models of the visual cortex
Cowley, B. R., Stan, P. L., Pillow, J. W., & Smith, M. A. (2026) · Nature · doi:10.1038/s41586-026-10150-1 · Cited by 21 · see citing works
Letner, J. G., Patel, P. R., Hsieh, J., Flores, I. M. S., della Valle, E., Walker, L. A., Weiland, J. D., Chestek, C. A., & Cai, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acbf78 · Cited by 16 · see citing works
Lim, M. J. R., Lo, Y. T., Tan, Y. Y., Lin, H.-Y., Wang, Y., Tan, D., Wang, E., Ma, Y. Y. N., Ng, J. J. W., Jefree, R. A., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb88e · Cited by 16 · see citing works
Long-term independent use of an intracortical brain–computer interface for speech and cursor control
Card, N. S., Singer-Clark, T. S., Peracha, H., Iacobacci, C., Hou, X., Wairagkar, M., Fogg, Z., Offenberg, E. C., Hochberg, L. R., Stavisky, S. D., et al. (2026) · Nature Medicine · doi:10.1038/s41591-026-04414-6 · Cited by 12 · see citing works
Monolithic three-dimensional neural probes from deterministic rolling of soft electronics
Qiang, Y., Gu, W., Jang, D., Shin, Y., Shi, D., Seo, K. J., Li, G., Vinnikova, S., Wu, S., Iyer, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01431-0 · Cited by 13 · see citing works
Hahn, N. V., Stein, E. A., Donoghue, J. P., Simeral, J. D., Hochberg, L. R., & Willett, F. R. (2025) · medRxiv · doi:10.1101/2025.07.02.25330310 · Cited by 11 · see citing works
Nanorobot-Based Direct Implantation of Flexible Neural Electrode for BCI
Li, T., Jiang, Y., Fu, X., Sun, Z., Yan, Y., Li, Y., & Liu, S. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3406940 · Cited by 9 · see citing works
Ethical imperatives in the commercialization of brain-computer interfaces
Boonstra, J. T. (2025) · IBRO Neuroscience Reports · doi:10.1016/j.ibneur.2025.10.004 · Cited by 8 · see citing works
The expanding repertoire of brain–computer interfaces
Ramsey, N. F., & Vansteensel, M. J. (2025) · Nature Medicine · doi:10.1038/s41591-024-03440-6 · Cited by 7 · see citing works
Implanted cortical neuroprosthetics for speech and movement restoration
Muirhead, W. R., Horsfall, H. L., Aicardi, C., Carolan, J., Akram, H., Vanhoestenberghe, A., Schaefer, A. T., & Marcus, H. J. (2024) · Journal of Neurology · doi:10.1007/s00415-024-12604-w · Cited by 7 · see citing works
Ikegaya, N., Mallela, A. N., Warnke, P. C., Kunigk, N. G., Liu, F., Schone, H. R., Verbaarschot, C., Hatsopoulos, N. G., Downey, J. E., Boninger, M. L., et al. (2024) · Journal of neurosurgery · doi:10.3171/2024.7.jns241296 · Cited by 7 · see citing works
Self-citationToward Natural Limb Function: A New Era in Prosthetic Innovation
Tian, Y., Wallace, D. M., Cederna, P. S., Chestek, C. A., & Kemp, S. W. P. (2025) · Annals of Neurology · doi:10.1002/ana.27287 · Cited by 8 · see citing works
Mahmoudian, B., Dalal, H., Lau, J. C., Corrigan, B. W., Abbass, M., Barker, K. C., Rankin, A., Chen, E. C. S., Peters, T. M., & Martínez-Trujillo, J. (2023) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2023.109948 · Cited by 6 · see citing works
Farzan, F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95730-4.00003-2 · Cited by 5 · see citing works
Biological and Mechanical Limitations for Chronic Fast‐Scan Cyclic Voltammetry Sensor Design
Perillo, M. L., Gupta, B., Saxena, A., Veltri, A. P., Li, W., Siegenthaler, J. R., & Purcell, E. K. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401808 · Cited by 7 · see citing works
Intracortical microstimulation in humans: a decade of safety and efficacyPreprint
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D. M., et al. (2025) · medRxiv · doi:10.1101/2025.08.11.25332271 · Cited by 5 · see citing works
Self-citationIndividualized brain-computer interface for people with disabilities: a review
Saha, S., Karlsson, P., Anderson, C. J., Kavehei, O., & McEwan, A. L. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1738876 · Cited by 4 · see citing works
Implantable Neural Speech Decoders: Recent Advances, Future Challenges
Jhilal, S., Marchesotti, S., Thirion, B., Soudrie, B., Giraud, A., & Mandonnet, E. (2025) · Neurorehabilitation and neural repair · doi:10.1177/15459683251369468 · Cited by 3 · see citing works
Flexible Microelectrode Arrays with Enhanced Electrochemical Properties Using Platinum Ditelluride
Jeanpierre, G. M., Omodon, S. C., Goldberg, S. D., González, J., Lu, H., Han, S. S., Baker, M. N., Madariaga, A., Rausch, M. K., Jung, Y., et al. (2025) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.5c01581 · Cited by 3 · see citing works
Lo, Y. T., Jiang, L., Woodington, B. J., Middya, S., Braendlein, M., Lam, J. L. W., Lim, M. J. R., Ng, V. Y. P., Rao, J. P., Chan, D. W. S., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad618c · Cited by 3 · see citing works
The auditory nerve implant—concept and device description of a novel electrical auditory prosthesis
Lenarz, T., Solzbacher, F., Rieth, L. W., Leber, M., Adams, M. E., Salcher, R. B., Warren, D. J., Oxenham, A. J., Dyballa, K.-H., Samii, A., et al. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00188-3 · Cited by 4 · see citing works
Signal properties and stability of a chronically implanted endovascular brain computer interfacePreprint
Chetty, N., Kacker, K., Feldman, A. K., Yoo, P. E., Bennett, J. D., Fry, A., Tal, I., Hardy, N. F., Ebrahimi, S., Echavarria, C., et al. (2025) · medRxiv · doi:10.1101/2025.09.19.25335897 · Cited by 3 · see citing works
Self-citationEnhanced Thin‐Film Encapsulation Through Micron‐Scale Anchors
Hemed, N. M., Pham, A., Zhao, E. T., Wang, P., & Melosh, N. A. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202402661 · Cited by 2 · see citing works
Forrest, A. M., Kunigk, N. G., Collinger, J. L., Gaunt, R. A., Chen, X., Geest, J. P. V., & Kozai, T. D. Y. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae1bda · Cited by 2 · see citing works
Self-citationLong-term safety and efficacy of intracortical microstimulation in humans
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D. M., et al. (2026) · Science Translational Medicine · doi:10.1126/scitranslmed.aec3728 · Cited by 2 · see citing works
Self-citationNam, K.-T., Kim, Y.-K., Lee, S.-K., & Park, J. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3461738 · Cited by 2 · see citing works
Bülbül, D. K., Walston, S. T., Duvan, F. T., Garrido, J. A., & Güçlü, B. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad9405 · Cited by 2 · see citing works
Innovations in Amputee Care in the United States: Access, Ethics, and Equity
Cain, J. J., Earley, E. J., Potter, B. K., Grover, P., Thomas, P., Stark, G. E., & White, A. (2025) · Prosthesis · doi:10.3390/prosthesis7060153 · Cited by 2 · see citing works
Cell adhesion molecule immobilized gold surfaces for enhanced neuron‐electrode interfaces
Aktaş, B., Özgün, A., Kilickap, B. D., & Gari̇pcan, B. (2023) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35310 · Cited by 4 · see citing works
Letner, J. G., Lam, J. L. W., Copenhaver, M. G., Barrow, M., Patel, P. R., Richie, J. M., Lee, J., Kim, H.-S., Cai, D., Weiland, J. D., et al. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1848862 · Cited by 1 · see citing works
Park, S., Kim, M. S., Lee, H., Lee, J., Chou, N., & Shin, H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117084 · Cited by 1 · see citing works
Meyer, L. M., & Zamani, M. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae6dfd · Cited by 1 · see citing works
Brain–computer interfaces and neuroprosthetics in the next era of neurosurgery
Banta, A. R., Fedorov, D., Altilia, A., Malliaras, G. G., & Barone, D. G. (2026) · British Journal of Neurosurgery · doi:10.1080/02688697.2026.2682817 · Cited by 1 · see citing works
Chen, Q., Huang, N., Tong, C., Liu, P., Que, S., Xue, H., Xiao, X., & Song, E. (2026) · npj Biosensing · doi:10.1038/s44328-026-00109-7 · Cited by 2 · see citing works
Motor Cortex Coverage Predicts Signal Strength of a Stentrode Endovascular Brain-Computer InterfacePreprint
Schone, H. R., Yoo, P. E., Fry, A., Chetty, N., Sawyer, A., Herbers, C., Liu, F., Moon, C., Hill, K. J., Majidi, S., et al. (2025) · medRxiv · doi:10.1101/2025.09.19.25335875 · Cited by 1 · see citing works
Self-citationLetner, J. G., Patel, P. R., Hsieh, J., Flores, I. M. S., della Valle, E., Walker, L. A., Weiland, J. D., Chestek, C. A., & Cai, D. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.10.07.511373
Which Ethical Issues Need to Be Considered Related to Microwires or Utah Arrays?
Young, M. J. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_7
Development of quality criteria for long-term testing of intracortical electrodes
Sielaff, C., Urban, U., & Froriep, U. P. (2023) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2023-1105
Long-Term Quality of Neural Signals: Criteria for Intracortical Implants
Charlotte, S., & Froriep, U. P. (2024) · doi:10.47952/gro-publ-203
Tracking single units across time using 16-channel microelectrode arrays
Jeakle, E. N., Abbott, J., Smith, T. J., Cogan, S. F., Hernandez-Reynoso, A. G., & Pancrazio, J. J. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781643
RETRACTED: Monolithic three-dimensional neural probes from deterministic rolling of soft electronicsPreprint
Qiang, Y., & Fang, H. (2025) · Research Square · doi:10.21203/rs.3.rs-6051081/v1
RetractedComparing a BCI communication system in a patient with Multiple System Atrophy, with an animal model
Premchand, B., Toe, K. K., Wang, C., Wan, K. R., Selvaratnam, T., Toh, V. E., Ng, W. H., Libedinsky, C., Chen, W., Lim, R., et al. (2025) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2025.111289
Lehmann, S. J., & Corneil, B. D. (2025) · Brain stimulation · doi:10.1016/j.brs.2025.07.013
A 192-Channel 1D CNN-Based Neural Feature Extractor in 65nm CMOS for Brain-Machine Interfaces
Bulfer, S., Gámez, J., Huang, A. Y., Haghi, B., Pedroni, V. A., Andersen, R. A., & Emami, A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3615121
Development of a non-human primate model for preclinical research of a novel auditory nerve implant
Sondh, I., Johnson, L. A., Ghose, G. M., Loveland, A., Larson, L., Lim, H. H., & Adams, M. E. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1669116
Research progress of neural implants: Toward robust brain-computer integration
Chen, Z., Tian, Y., Zeng, M., Wu, X., Wu, C., Wei, D., Sun, J. K., Zhou, L. E. T. A. O., Ding, J., & Fan, H. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.177125
Intracortical BCI Performance is Robust to Changes in Attentional Load During Dual-TaskingPreprint
Canario, E., Shearer, C., Akçakaya, M., Weber, D. J., Chase, S. M., & Collinger, J. L. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.16.732398
Self-citationRoberts, S. M., Carter, J. S., Jensen, B. D., Vanfleet, R. R., & Davis, R. C. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1864874
- Authors
- Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G.
- Affiliations
- University of Chicago (US)
- University of Pittsburgh (US)
- University College London (GB)
- University of Minnesota (US)
- Corresponding author
- Hatsopoulos, Nicholas G.
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-12-01
- Volume
- 18
- Issue
- 6
- Pages
- 066044
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC8981395
- OpenAlex
- W3215420535
- Cited by
- 66
- References
- 30
- Citations by year
- 2026: 12 · 2025: 24 · 2024: 17 · 2023: 9 · 2022: 4
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01 NS045853)
- Defense Advanced Research Projects Agency (N66001-10-C-4056)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- Utah electrode array, chronic electrophysiology, signal-to-noise ratio, electrode reliability, platinum metallization, rhesus monkeys, primary motor cortex, prefrontal cortex, somatosensory cortex, premotor cortex
- MeSH terms
- Animals, Electrodes, Implanted, Longevity, Macaca mulatta, Microelectrodes, Utah, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review