CoChat

Self-recalibrating classifiers for intracortical brain–computer interfaces

Open access
Bishop, William, Chestek, Cynthia C, Gilja, Vikash, Nuyujukian, Paul, Foster, Justin D, Ryu, Stephen I, Shenoy, Krishna V, Yu, Byron M · 2014 · Journal of Neural Engineering
Cited by 60

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Intracortical brain-computer interface (BCI) decoders are typically retrained daily to maintain stable performance. Self-recalibrating decoders aim to remove the burden this may present in the clinic by training themselves autonomously during normal use but have only been developed for continuous control. Here we address the problem for discrete decoding (classifiers). APPROACH: We recorded threshold crossings from 96-electrode arrays implanted in the motor cortex of two rhesus macaques performing center-out reaches in 7 directions over 41 and 36 separate days spanning 48 and 58 days in total for offline analysis. MAIN RESULTS: We show that for the purposes of developing a self-recalibrating classifier, tuning parameters can be considered as fixed within days and that parameters on the same electrode move up and down together between days. Further, drift is constrained across time, which is reflected in the performance of a standard classifier which does not progressively worsen if it is not retrained daily, though overall performance is reduced by more than 10% compared to a daily retrained classifier. Two novel self-recalibrating classifiers produce a ~15% increase in classification accuracy over that achieved by the non-retrained classifier to nearly recover the performance of the daily retrained classifier. SIGNIFICANCE: We believe that the development of classifiers that require no daily retraining will accelerate the clinical translation of BCI systems. Future work should test these results in a closed-loop setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/11/2/026001

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Reach and grasp by people with tetraplegia using a neurally controlled robotic arm

    Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×

    “However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
    Background
  • Response of brain tissue to chronically implanted neural electrodes

    Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×

    “Movements of the recording array relative to the brain (Santhanam et al 2007), scar tissue buildup (Polikov et al 2005), behavioral changes (Chestek et al 2007) and neural plasticity (Taylor et al 2002, Jarosiewicz et al 2008, Ganguly and Carmena 2009, Chase et al 2012) may all cause tuning…”
    BackgroundMethod
  • High-performance neuroprosthetic control by an individual with tetraplegia

    Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×

    “However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
    Background
  • Cortical control of a prosthetic arm for self-feeding

    Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591

  • A high-performance brain–computer interface

    Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 5×

    “Potential clinical applications for BCI classifiers include making selections from a menu interface or virtual keyboard (e.g., Scherer et al 2004, Santhanam et al 2006, Brunner et al 2011), selecting among grasp types for a prosthetic hand (e.g., Pistohl et al 2012, Chestek et al 2013), classifying…”
    BackgroundMethodInfluentialSelf-citation
  • Cognitive Control Signals for Neural Prosthetics

    Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×

    “However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
    Background
  • Emergence of a stable cortical map for neuroprosthetic control

    Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 1×

    “…the recording array relative to the brain (Santhanam et al 2007), scar tissue buildup (Polikov et al 2005), behavioral changes (Chestek et al 2007) and neural plasticity (Taylor et al 2002, Jarosiewicz et al 2008, Ganguly and Carmena 2009, Chase et al 2012) may all cause tuning parameters to drift.”
    Background
  • A high-performance neural prosthesis enabled by control algorithm design

    Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564

    Self-citation
  • Towards a cure for BCI illiteracy

    Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501 · cited 1×

    “…algorithms include approaches based on variational Kalman filtering (Sykacek and Roberts 2002, Sykacek et al 2004), expectation maximization (EM) (Blumberg et al 2007) and a variety of other methods to update the parameters of an LDA classifier (Vidaurre et al 2008, Vidaurre and Blankertz 2010).”
    Method
  • Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex

    Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350

    Self-citation

Show all 14 references

Cited by

Metadata

Authors
Bishop, W., Chestek, C. C., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M.
Venue
Journal of Neural Engineering
Published
2014-02-06
Volume
11
Issue
2
Pages
026001
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2045572716
Cited by
60
References
14
FWCI
2.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.