Self-recalibrating classifiers for intracortical brain–computer interfaces
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Intracortical brain-computer interface (BCI) decoders are typically retrained daily to maintain stable performance. Self-recalibrating decoders aim to remove the burden this may present in the clinic by training themselves autonomously during normal use but have only been developed for continuous control. Here we address the problem for discrete decoding (classifiers). APPROACH: We recorded threshold crossings from 96-electrode arrays implanted in the motor cortex of two rhesus macaques performing center-out reaches in 7 directions over 41 and 36 separate days spanning 48 and 58 days in total for offline analysis. MAIN RESULTS: We show that for the purposes of developing a self-recalibrating classifier, tuning parameters can be considered as fixed within days and that parameters on the same electrode move up and down together between days. Further, drift is constrained across time, which is reflected in the performance of a standard classifier which does not progressively worsen if it is not retrained daily, though overall performance is reduced by more than 10% compared to a daily retrained classifier. Two novel self-recalibrating classifiers produce a ~15% increase in classification accuracy over that achieved by the non-retrained classifier to nearly recover the performance of the daily retrained classifier. SIGNIFICANCE: We believe that the development of classifiers that require no daily retraining will accelerate the clinical translation of BCI systems. Future work should test these results in a closed-loop setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“Movements of the recording array relative to the brain (Santhanam et al 2007), scar tissue buildup (Polikov et al 2005), behavioral changes (Chestek et al 2007) and neural plasticity (Taylor et al 2002, Jarosiewicz et al 2008, Ganguly and Carmena 2009, Chase et al 2012) may all cause tuning…”
BackgroundMethodHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 5×
“Potential clinical applications for BCI classifiers include making selections from a menu interface or virtual keyboard (e.g., Scherer et al 2004, Santhanam et al 2006, Brunner et al 2011), selecting among grasp types for a prosthetic hand (e.g., Pistohl et al 2012, Chestek et al 2013), classifying…”
BackgroundMethodInfluentialSelf-citationCognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“However, in almost all cases these decoders are retrained daily in a supervised manner to maintain their accuracy (e.g., Musallam et al 2004, Santhanam et al 2006, Velliste et al 2008, Li et al 2009, Hochberg et al 2012, Gilja et al 2012, Collinger et al 2012, Shanechi et al 2012).”
BackgroundEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 1×
“…the recording array relative to the brain (Santhanam et al 2007), scar tissue buildup (Polikov et al 2005), behavioral changes (Chestek et al 2007) and neural plasticity (Taylor et al 2002, Jarosiewicz et al 2008, Ganguly and Carmena 2009, Chase et al 2012) may all cause tuning parameters to drift.”
BackgroundA high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Self-citationTowards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501 · cited 1×
“…algorithms include approaches based on variational Kalman filtering (Sykacek and Roberts 2002, Sykacek et al 2004), expectation maximization (EM) (Blumberg et al 2007) and a variety of other methods to update the parameters of an LDA classifier (Vidaurre et al 2008, Vidaurre and Blankertz 2010).”
MethodChestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Self-citation
Cited by
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“…reports ( Gilja et al., 2012 ; Simeral et al., 2011 ; Nuyujukian et al., 2015 ; Gilja et al., 2015 ; Hochberg et al., 2012 ; Chestek et al., 2011 ; Bishop et al., 2014 ; Flint et al., 2013 ; Nuyujukian et al., 2014 ), demonstrates that intracortical BCIs may be useful for years post-implantation.”
BackgroundSelf-citationMaking brain–machine interfaces robust to future neural variability
Sussillo, D., Stavisky, S. D., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2016) · Nature Communications · doi:10.1038/ncomms13749 · Cited by 213
Self-citationDegenhart, A. D., Bishop, W. E., Oby, E. R., Tyler-Kabara, E. C., Chase, S. M., Batista, A. P., & Yu, B. M. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0542-9 · Cited by 212
Self-citationCombining Decoder Design and Neural Adaptation in Brain-Machine Interfaces
Shenoy, K. V., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.08.038 · Cited by 177
“…et al., 2005; Shpigelman et al., 2009; DiGiovanna et al., 2009; Santhanam et al., 2009; Koyama et al., 2010; Heliot et al., 2010a; Li et al., 2011; Mahmoudi and Sanchez, 2011; Orsborn et al., 2012; Gilja et al., 2012; Dangi et al., 2013; Fan et al., 2014; Bishop et al., 2014; Dangi et al., 2014).”
Self-citationSchwemmer, M. A., Skomrock, N. D., Sederberg, P. B., Ting, J. E., Sharma, G., Bockbrader, M. A., & Friedenberg, D. A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0171-y · Cited by 163
Intracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Latent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103
“…using a weighted sliding average (Orsborn et al., 2012; Dangi et al., 2013), automated decoder recalibration by updating “tuning” estimates daily (Bishop et al., 2014), continuous recalibration by retrospectively inferring the user’s intention among a set of fixed targets (Jarosiewicz et al.,…”
BackgroundMethodStabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K., Ma, X., Miller, L. E., & Pandarinath, C. (2022) · doi:10.1101/2022.04.06.487388 · Cited by 71
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Self-citation
Metadata
- Authors
- Bishop, W., Chestek, C. C., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-02-06
- Volume
- 11
- Issue
- 2
- Pages
- 026001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2045572716
- Cited by
- 60
- References
- 14
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.