Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Brain-computer interfaces (BCI) as a rehabilitation tool have been used to restore functions in patients with motor impairments by actively involving the central nervous system and triggering prosthetic devices according to the detected pre-movement state. However, since EEG signals are highly variable between subjects and recording sessions, typically a BCI is calibrated at the beginning of each session. This process is inconvenient especially for patients suffering locomotor disabilities in maintaining a bipedal position for a longer time. This paper presents a continuous EEG decoder of a pre-movement state in self-initiated walking and the usage of this decoder from session to session without recalibrating. APPROACH: Ten healthy subjects performed a self-initiated walking task during three sessions, with an intersession interval of one week. The implementation of our continuous decoder is based on the combination of movement-related cortical potential (MRCP) and event-related desynchronization (ERD) features with sparse classification models. MAIN RESULTS: During intrasession our technique detects the pre-movement state with 70% accuracy. Moreover this decoder can be applied from session to session without recalibration, with a decrease in performance of about 4% on a one- or two-week intersession interval. SIGNIFICANCE: Our detection model operates in a continuous manner, which makes it a straightforward asset for rehabilitation scenarios. By using both temporal and spectral information we attained higher detection rates than the ones obtained with the MRCP and ERD detection models, both during the intrasession and intersession conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Probabilistic Interpretation of Precision, Recall and F-Score, with Implication for Evaluation
Goutte, C., & Gaussier, E. (2005) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-31865-1_25 · Cited by 2,285
What is the Bereitschaftspotential?
Shibasaki, H., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.025 · Cited by 1,169
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Pfurtscheller, G., & Aranibar, A. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90063-4 · Cited by 758
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Cited by
Ofner, P., Schwarz, A., Pereira, J., Wyss, D., Wildburger, R., & Müller-Putz, G. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-43594-9 · Cited by 166
EEG neural correlates of goal-directed movement intention
Pereira, J., Ofner, P., Schwarz, A., Sburlea, A. I., & Müller-Putz, G. R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.030 · Cited by 116
“Regarding the features, we exclusively used time features but recent studies show that features from the time-domain combined with spectral features improve movement intention detection (Jochumsen et al., 2015a; Sburlea et al., 2015).”
Self-citationPrediction of gait intention from pre-movement EEG signals: a feasibility study
Shafiul Hasan, S. M., Siddiquee, M. R., Atri, R., Ramon, R., Marquez, J. S., & Bai, O. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00675-5 · Cited by 63
“The current studies [28, 29] either use EEG signal from both before and after the movement initiation and termination or use a large portion of pre-movement EEG data for proper baseline information.”
MethodAsynchronous Prediction of Human Gait Intention in a Pseudo Online Paradigm Using Wavelet Transform
Hasan, S. M. S., Siddiquee, M. R., & Bai, O. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2998778 · Cited by 22
“[28], [29] used a smaller prediction window of [−1.”
Quiles, V., Ferrero, L., Iáñez, E., Ortiz, M., Cano, J. M., & Azorín, J. M. (2022) · Applied Sciences · doi:10.3390/app12010415 · Cited by 10
Metadata
- Authors
- Sburlea, A. I., Montesano, L., & Minguez, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-04-27
- Volume
- 12
- Issue
- 3
- Pages
- 036007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2092889121
- Cited by
- 69
- References
- 6
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration. https://app.cochat.ai/papers/10.1088/1741-2560/12/3/036007
- The paper
- Sburlea, A. I., Montesano, L., & Minguez, J. (2015). Continuous detection of the self-initiated walking pre-movement state from EEG correlates without session-to-session recalibration. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/12/3/036007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.