Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque

Abstract

Objective . Loss of even part of the upper limb is a devastating injury. In order to fully restore natural function when lacking sufficient residual musculature, it is necessary to record directly from peripheral nerves. However, current approaches must make trade-offs between signal quality and longevity which limit their clinical potential. To address this issue, we have developed the regenerative peripheral nerve interface (RPNI) and tested its use in non-human primates. Approach . The RPNI consists of a small, autologous partial muscle graft reinnervated by a transected peripheral nerve branch. After reinnervation, the graft acts as a bioamplifier for descending motor commands in the nerve, enabling long-term recording of high signal-to-noise ratio (SNR), functionally-specific electromyographic (EMG) signals. We implanted nine RPNIs on separate branches of the median and radial nerves in two rhesus macaques who were trained to perform cued finger movements. Main results. No adverse events were noted in either monkey, and we recorded normal EMG with high SNR (>8) from the RPNIs for up to 20 months post-implantation. Using RPNI signals recorded during the behavioral task, we were able to classify each monkey’s finger movements as flexion, extension, or rest with >96% accuracy. RPNI signals also enabled functional prosthetic control, allowing the monkeys to perform the same behavioral task equally well with either physical finger movements or RPNI-based movement classifications. Significance . The RPNI signal strength, stability, and longevity demonstrated here represents a promising method for controlling advanced prosthetic limbs and fully restoring natural movement.

Overview

Integrity signals

Registry

Crossref · 10.1088/1741-2560/13/4/046007

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Cited by

See all 78

Metadata

Authors
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
Affiliations
University of Michigan (US)
Corresponding author
  • Irwin, Z T
  • Schroeder, K E
  • Vu, P P
  • Tat, D M
  • Bullard, A J
  • Woo, S L
  • Sando, I C
  • Urbanchek, M G
  • Cederna, P S
  • Chestek, C A
Venue
Journal of Neural Engineering
Published
2016-06-01
Volume
13
Issue
4
Pages
046007
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2418815232
Cited by
78
References
34
Citations by year
2026: 4 · 2025: 9 · 2024: 14 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 8 · 2019: 13 · 2018: 6 · 2017: 4
FWCI
4.31
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Plastic Surgery Foundation
  • Wallace H. Coulter Foundation
  • Frederick A. Coller Surgical Society
  • NSF Graduate Research Fellowship
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
regenerative peripheral nerve interface, prosthetic hand control, peripheral nerve recording, muscle reinnervation, median nerve, radial nerve, rhesus monkeys, finger movement classification, upper limb amputation
MeSH terms
Animals, Artificial Limbs, Electrodes, Implanted, Electromyography, Fingers, Hand, Macaca mulatta, Movement, Nerve Regeneration, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, Muscle, Skeletal, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque. https://app.cochat.ai/papers/10.1088/1741-2560/13/4/046007
The paper
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016). Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/4/046007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.