The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque
Abstract
Objective . Loss of even part of the upper limb is a devastating injury. In order to fully restore natural function when lacking sufficient residual musculature, it is necessary to record directly from peripheral nerves. However, current approaches must make trade-offs between signal quality and longevity which limit their clinical potential. To address this issue, we have developed the regenerative peripheral nerve interface (RPNI) and tested its use in non-human primates. Approach . The RPNI consists of a small, autologous partial muscle graft reinnervated by a transected peripheral nerve branch. After reinnervation, the graft acts as a bioamplifier for descending motor commands in the nerve, enabling long-term recording of high signal-to-noise ratio (SNR), functionally-specific electromyographic (EMG) signals. We implanted nine RPNIs on separate branches of the median and radial nerves in two rhesus macaques who were trained to perform cued finger movements. Main results. No adverse events were noted in either monkey, and we recorded normal EMG with high SNR (>8) from the RPNIs for up to 20 months post-implantation. Using RPNI signals recorded during the behavioral task, we were able to classify each monkey’s finger movements as flexion, extension, or rest with >96% accuracy. RPNI signals also enabled functional prosthetic control, allowing the monkeys to perform the same behavioral task equally well with either physical finger movements or RPNI-based movement classifications. Significance . The RPNI signal strength, stability, and longevity demonstrated here represents a promising method for controlling advanced prosthetic limbs and fully restoring natural movement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Invasive recording techniques routinely use peripheral in vivo tissues with electroneurography (ENG)[277,278] and electromyography (EMG),[279,280] which can record peripheral nerve activity and muscle electrical signals respectively.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [277]
In the citing paper
“This process creates a stable, peripheral nerve bioamplifier that produces high-amplitude EMG signals, which could be used to control a prosthetic device (14–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [15]
In the citing paper
“results from previous animal work, which demonstrated that it took approximately 3 months for RPNIs to mature and stabilize (12, 15–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [15]
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“As the decoding features, we extracted four temporal characteristics of the EMG waveform [14, 21] in successive 50 ms time bins: (1) mean absolute value, (2) number of zero crossings, (3) number of slope changes, and (4) waveform line length.”
MethodUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111 · cited 2×
“this state-of-the-art technology is not significantly better than that of simple body-powered hooks [1, 5].”
BackgroundTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“Signals recorded by epineural electrodes are typically low amplitude and corrupted by much larger EMG activity from the surrounding muscles [7, 8].”
BackgroundUpper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
The regeneration of skeletal muscle fibers following injury: a review
CARLSON, B. M., & FAULKNER, J. A. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315030-00003 · Cited by 419
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“As is typical, the mature muscle graft is somewhat smaller than the original graft, but is well vascularized and appears healthy.”
BackgroundDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342 · cited 1×
“Both monkeys regained full use of the hand and limb within three days post-surgery, except in the case of Monkey R’s swelling in which the animal recovered full use after one week, following fluid drainage by veterinary staff.”
Background
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationProprioception from a neurally controlled lower-extremity prosthesis
Clites, T. R., Carty, M. J., Ullauri, J. B., Carney, M. E., Mooney, L. M., Duval, J.-F., Srinivasan, S. S., & Herr, H. M. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8373 · Cited by 233
Surgical Algorithm for Neuroma Management: A Changing Treatment Paradigm
Eberlin, K. R., & Ducic, I. (2018) · Plastic and Reconstructive Surgery - Global Open · doi:10.1097/gox.0000000000001952 · Cited by 207
High‐Performance Graphene‐Fiber‐Based Neural Recording Microelectrodes
Wang, K., Frewin, C. L., Esrafilzadeh, D., Yu, C., Wang, C., Pancrazio, J. J., Romero‐Ortega, M., Jalili, R., & Wallace, G. (2019) · Advanced Materials · doi:10.1002/adma.201805867 · Cited by 191
Metadata
- Authors
- Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Irwin, Z T
- Schroeder, K E
- Vu, P P
- Tat, D M
- Bullard, A J
- Woo, S L
- Sando, I C
- Urbanchek, M G
- Cederna, P S
- Chestek, C A
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-06-01
- Volume
- 13
- Issue
- 4
- Pages
- 046007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2418815232
- Cited by
- 78
- References
- 34
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 14 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 8 · 2019: 13 · 2018: 6 · 2017: 4
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Plastic Surgery Foundation
- Wallace H. Coulter Foundation
- Frederick A. Coller Surgical Society
- NSF Graduate Research Fellowship
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- regenerative peripheral nerve interface, prosthetic hand control, peripheral nerve recording, muscle reinnervation, median nerve, radial nerve, rhesus monkeys, finger movement classification, upper limb amputation
- MeSH terms
- Animals, Artificial Limbs, Electrodes, Implanted, Electromyography, Fingers, Hand, Macaca mulatta, Movement, Nerve Regeneration, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, Muscle, Skeletal, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque. https://app.cochat.ai/papers/10.1088/1741-2560/13/4/046007
- The paper
- Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016). Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/4/046007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.