Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Objective . Loss of even part of the upper limb is a devastating injury. In order to fully restore natural function when lacking sufficient residual musculature, it is necessary to record directly from peripheral nerves. However, current approaches must make trade-offs between signal quality and longevity which limit their clinical potential. To address this issue, we have developed the regenerative peripheral nerve interface (RPNI) and tested its use in non-human primates. Approach . The RPNI consists of a small, autologous partial muscle graft reinnervated by a transected peripheral nerve branch. After reinnervation, the graft acts as a bioamplifier for descending motor commands in the nerve, enabling long-term recording of high signal-to-noise ratio (SNR), functionally-specific electromyographic (EMG) signals. We implanted nine RPNIs on separate branches of the median and radial nerves in two rhesus macaques who were trained to perform cued finger movements. Main results. No adverse events were noted in either monkey, and we recorded normal EMG with high SNR (>8) from the RPNIs for up to 20 months post-implantation. Using RPNI signals recorded during the behavioral task, we were able to classify each monkey’s finger movements as flexion, extension, or rest with >96% accuracy. RPNI signals also enabled functional prosthetic control, allowing the monkeys to perform the same behavioral task equally well with either physical finger movements or RPNI-based movement classifications. Significance . The RPNI signal strength, stability, and longevity demonstrated here represents a promising method for controlling advanced prosthetic limbs and fully restoring natural movement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Invasive recording techniques routinely use peripheral in vivo tissues with electroneurography (ENG)[277,278] and electromyography (EMG),[279,280] which can record peripheral nerve activity and muscle electrical signals respectively.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [277]
In the citing paper
“This process creates a stable, peripheral nerve bioamplifier that produces high-amplitude EMG signals, which could be used to control a prosthetic device (14–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [15]
In the citing paper
“results from previous animal work, which demonstrated that it took approximately 3 months for RPNIs to mature and stabilize (12, 15–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [15]
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“As the decoding features, we extracted four temporal characteristics of the EMG waveform [14, 21] in successive 50 ms time bins: (1) mean absolute value, (2) number of zero crossings, (3) number of slope changes, and (4) waveform line length.”
MethodUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111 · cited 2×
“this state-of-the-art technology is not significantly better than that of simple body-powered hooks [1, 5].”
BackgroundTargeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“Signals recorded by epineural electrodes are typically low amplitude and corrupted by much larger EMG activity from the surrounding muscles [7, 8].”
BackgroundUpper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
The regeneration of skeletal muscle fibers following injury: a review
CARLSON, B. M., & FAULKNER, J. A. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315030-00003 · Cited by 419
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“As is typical, the mature muscle graft is somewhat smaller than the original graft, but is well vascularized and appears healthy.”
BackgroundDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342 · cited 1×
“Both monkeys regained full use of the hand and limb within three days post-surgery, except in the case of Monkey R’s swelling in which the animal recovered full use after one week, following fluid drainage by veterinary staff.”
BackgroundProsthesis use in persons with lower- and upper-limb amputation
Raichle, K. A. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.09.0151 · Cited by 288
Prosthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 266
Prosthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · cited 1×
“The two electrode types which have been the most studied in terms of direct nerve recording and subsequent prosthesis control are the longitudinal intra-fascicular electrode [28] and the Utah electrode array [29].”
BackgroundMcFarland, L. V., Winkler, S. L. H., Heinemann, A. W., Jones, M., & Esquenazi, A. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.03.0027 · Cited by 227
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Kung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181
Self-citationTargeted reinnervation for transhumeral amputees: current surgical technique and update on results
Dumanian, G. A., Ko, J. H., O’Shaughnessy, K. D., Kim, P. S., Wilson, C. J., & Kuiken, T. A. (2009) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181b038c9 · Cited by 130
Real-time simultaneous and proportional myoelectric control using intramuscular EMG
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066013 · Cited by 126
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · cited 1×
“The EDCa RPNI is shown in figure 5(a), at the time of implantation and at the time of graft explantation four months later.”
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · cited 1×
“Though these issues could be somewhat mitigated by further signal processing [9, 33] or physical shielding of the array [34], successful recording and control have not been demonstrated for longer than one month, with questions remaining as to nerve health under longer-term implantation of these electrodes.”
BackgroundMorphologic Regions of the Multitendoned Extrinsic Finger Muscles in the Monkey Forearm
Serlin, D. M., & Schieber, M. H. (1993) · Cells Tissues Organs · doi:10.1159/000147465 · Cited by 82
Cipriani, C., Segil, J. L., Birdwell, J. A., & Weir, R. F. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2301234 · Cited by 81 · cited 1×
“Both monkeys regained full use of the hand and limb within three days post-surgery, except in the case of Monkey R’s swelling in which the animal recovered full use after one week, following fluid drainage by veterinary staff.”
BackgroundClark, G. A., Wendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Normann, R. A., Warren, D. J., & Hutchinson, D. T. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944001 · Cited by 78
Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091149 · Cited by 72
Occupational therapy protocol for amputees with targeted muscle reinnervation
Stubblefield, K. A., Miller, L. A., Lipschutz, R. D., & Kuiken, T. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.10.0138 · Cited by 66
Invasive neural prosthesis for neural signal detection and nerve stimulation
Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., & Warwick, K. (2005) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.854 · Cited by 66 · cited 1×
“Both have been implanted in multiple amputees and used to provide control functionality similar to this study [30, 31].”
MethodSpiral nerve cuff electrode for recordings of respiratory output
Sahin, M., Haxhiu, M. A., Durand, D. M., & Dreshaj, I. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.1.317 · Cited by 47
In vivo characterization of regenerative peripheral nerve interface function
Ursu, D. C., Urbanchek, M. G., Nedic, A., Cederna, P. S., & Gillespie, R. B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026012 · Cited by 46 · cited 1×
“Following veterinary recommendation, buprenorphine was administered during the first 24 h following each surgery, and carprofen and cefazolin administered for the first week to control possible pain and prevent wound infection.”
MethodSelf-citationA Fully Implanted Intramuscular Bipolar Myoelectric Signal Recording Electrode
Memberg, W. D., Stage, T. G., & Kirsch, R. F. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12165 · Cited by 34
Birdwell, J. A., Hargrove, L. J., Weir, R. F. F., & Kuiken, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2344854 · Cited by 33 · cited 1×
“Both monkeys regained full use of the hand and limb within three days post-surgery, except in the case of Monkey R’s swelling in which the animal recovered full use after one week, following fluid drainage by veterinary staff.”
BackgroundSkeletal muscle fiber regeneration following heterotopic autotransplantation in cats
Faulkner, J. A., Maxwell, L. C., Mufti, S. A., & Carlson, B. M. (1976) · Life Sciences · doi:10.1016/0024-3205(76)90402-1 · Cited by 18
A Review of Free Muscle Grafting
Cedars, M. G., & Miller, T. A. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198411000-00024 · Cited by 17
The Microscopic Morphology of Orthotopic Free Muscle Grafts in Rabbits
Cedars, M. G., Das, S. K., Roth, J. C., & Miller, T. A. (1983) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198308000-00010 · Cited by 3
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationProprioception from a neurally controlled lower-extremity prosthesis
Clites, T. R., Carty, M. J., Ullauri, J. B., Carney, M. E., Mooney, L. M., Duval, J.-F., Srinivasan, S. S., & Herr, H. M. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8373 · Cited by 233
Surgical Algorithm for Neuroma Management: A Changing Treatment Paradigm
Eberlin, K. R., & Ducic, I. (2018) · Plastic and Reconstructive Surgery - Global Open · doi:10.1097/gox.0000000000001952 · Cited by 207
High‐Performance Graphene‐Fiber‐Based Neural Recording Microelectrodes
Wang, K., Frewin, C. L., Esrafilzadeh, D., Yu, C., Wang, C., Pancrazio, J. J., Romero‐Ortega, M., Jalili, R., & Wallace, G. (2019) · Advanced Materials · doi:10.1002/adma.201805867 · Cited by 191
Metadata
- Authors
- Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Irwin, Z T
- Schroeder, K E
- Vu, P P
- Tat, D M
- Bullard, A J
- Woo, S L
- Sando, I C
- Urbanchek, M G
- Cederna, P S
- Chestek, C A
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-06-01
- Volume
- 13
- Issue
- 4
- Pages
- 046007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2418815232
- Semantic Scholar
- 250078c6d815fd6ab6d32eb5c01e36cf5673fbf8
- Cited by
- 78
- References
- 34
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 14 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 8 · 2019: 13 · 2018: 6 · 2017: 4
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Plastic Surgery Foundation
- Wallace H. Coulter Foundation
- Frederick A. Coller Surgical Society
- NSF Graduate Research Fellowship
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- regenerative peripheral nerve interface, prosthetic hand control, peripheral nerve recording, muscle reinnervation, median nerve, radial nerve, rhesus monkeys, finger movement classification, upper limb amputation
- MeSH terms
- Animals, Artificial Limbs, Electrodes, Implanted, Electromyography, Fingers, Hand, Macaca mulatta, Movement, Nerve Regeneration, Peripheral Nerves, Prosthesis Design, Psychomotor Performance, Muscle, Skeletal, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.