Spatial co-adaptation of cortical control columns in a micro-ECoG brain–computer interface
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Electrocorticography (ECoG) has been used for a range of applications including electrophysiological mapping, epilepsy monitoring, and more recently as a recording modality for brain-computer interfaces (BCIs). Studies that examine ECoG electrodes designed and implanted chronically solely for BCI applications remain limited. The present study explored how two key factors influence chronic, closed-loop ECoG BCI: (i) the effect of inter-electrode distance on BCI performance and (ii) the differences in neural adaptation and performance when fixed versus adaptive BCI decoding weights are used. APPROACH: The amplitudes of epidural micro-ECoG signals between 75 and 105 Hz with 300 μm diameter electrodes were used for one-dimensional and two-dimensional BCI tasks. The effect of inter-electrode distance on BCI control was tested between 3 and 15 mm. Additionally, the performance and cortical modulation differences between constant, fixed decoding using a small subset of channels versus adaptive decoding weights using the entire array were explored. MAIN RESULTS: Successful BCI control was possible with two electrodes separated by 9 and 15 mm. Performance decreased and the signals became more correlated when the electrodes were only 3 mm apart. BCI performance in a 2D BCI task improved significantly when using adaptive decoding weights (80%-90%) compared to using constant, fixed weights (50%-60%). Additionally, modulation increased for channels previously unavailable for BCI control under the fixed decoding scheme upon switching to the adaptive, all-channel scheme. SIGNIFICANCE: Our results clearly show that neural activity under a BCI recording electrode (which we define as a 'cortical control column') readily adapts to generate an appropriate control signal. These results show that the practical minimal spatial resolution of these control columns with micro-ECoG BCI is likely on the order of 3 mm. Additionally, they show that the combination and interaction between neural adaptation and machine learning are critical to optimizing ECoG BCI performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Ray, S., Crone, N. E., Niebur, E., Franaszczuk, P. J., & Hsiao, S. S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2848-08.2008 · Cited by 722
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454 · cited 1×
“Further work is needed to understand how best to utilize separate frequency ranges from a single channel for separate independent control signals (McFarland et al 2010).”
BackgroundClosed-Loop Decoder Adaptation Shapes Neural Plasticity for Skillful Neuroprosthetic Control
Orsborn, A. L., Moorman, H. G., Overduin, S. A., Shanechi, M. M., Dimitrov, D. F., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.04.048 · Cited by 280
Cited by
Plug-and-play control of a brain–computer interface through neural map stabilization
Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0662-5 · Cited by 126
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
High-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42
“Previous studies have demonstrated that humans [7, 8] and nonhuman primates [9] can control external devices, such as computer cursors, by decoding the measured brain activity.”
BackgroundLong-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“In most of these works, subdural electrodes were used because they provide closer contact with the source signal except for [18] reporting on epidural microECoG.”
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
“Significant outcomes have been achieved in controlling paralysed [1] and prosthetic arms [2–5] for paralysed patients; computer cursor control [4, 6, 7] for brain typing, handwriting [8] and speech intention decoding [9, 10] for communication recovery and enhancement; controlling a ‘third thumb’ for human ability augm…”
Background
Metadata
- Authors
- Rouse, A. G., Williams, J. J., Wheeler, J. J., & Moran, D. W.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-09-21
- Volume
- 13
- Issue
- 5
- Pages
- 056018
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2523314560
- Cited by
- 40
- References
- 6
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial co-adaptation of cortical control columns in a micro-ECoG brain–computer interface. https://app.cochat.ai/papers/10.1088/1741-2560/13/5/056018
- The paper
- Rouse, A. G., Williams, J. J., Wheeler, J. J., & Moran, D. W. (2016). Spatial co-adaptation of cortical control columns in a micro-ECoG brain–computer interface. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/5/056018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.