The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Open accessAbstract
OBJECTIVE: Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. APPROACH: Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. MAIN RESULTS: Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. SIGNIFICANCE: This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“several strategies for minimizing trauma and the inflammatory responses have been investigated, for example, the reduction of the cross-sectional area of the electrodes (Seymour and Kipke, 2007) and the use of more flexible and soft materials that better match the properties of the surrounding tissue”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Patel et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
Paxinos, G., & Watson, C. (1983) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 28,585
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., WATSON, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,514
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Neuron-type-specific signals for reward and punishment in the ventral tegmental area
Cohen, J. Y., Haesler, S., Vong, L., Lowell, B. B., & Uchida, N. (2012) · Nature · doi:10.1038/nature10754 · Cited by 1,318
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Research works printed but not linked: 2
- 2011, 10.1520/F1980-07R11 · DOI
- Kozai, 2014, Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes, Biomaterials, 35, 9255, 10.1016/j.biomaterials.2014.07.039 · DOI · Paper page
Cited by
Sorted by citations
Items 201–204 of 204
Tahmasebi, G., Vargas, S. L., Fofié, C. K., Haghighi, P., Solís, E. J., Massaquoi, A. C., & Pancrazio, J. J. (2026) · Journal of Neurophysiology · doi:10.1152/jn.00112.2026
Zheng, K., Yu, W., Gu, Y., He, Z., Wang, X., & Li, Y. (2026) · ACS Materials Letters · doi:10.1021/acsmaterialslett.6c00685
Fibre-architected intelligent permeable bioelectronics
Wu, Z., Zhang, Y., Huang, Q., & Zheng, Z. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00500-z
Conducting polymers for implantable neural electrodes in brain–computer interfaces
Zhu, J., Liu, R., Jiang, H., Liu, X., Kong, Z., Wang, L., Xu, W., & Wang, Y. (2026) · Journal of Materials Chemistry B · doi:10.1039/d6tb01636g
Metadata
- Authors
- Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- University of Pittsburgh (US)
- Corresponding author
- Patel, Paras R
- Zhang, Huanan
- Robbins, Matthew T
- Nofar, Justin B
- Marshall, Shaun P
- Kobylarek, Michael J
- Kozai, Takashi D Y
- Kotov, Nicholas A
- Chestek, Cynthia A
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-10-05
- Volume
- 13
- Issue
- 6
- Pages
- 066002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC5118062
- OpenAlex
- W2529123936
- Cited by
- 204
- References
- 77
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 17 · 2023: 18 · 2022: 16 · 2021: 34 · 2020: 34 · 2019: 24 · 2018: 24 · 2017: 9 · 2016: 2
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- McKnight Foundation
- National Institute of Neurological Disorders and Stroke (1R01NS094396)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- chronic neural recording, electrode stability, PEDOT coating, accelerated aging, glial scar, silicon electrodes, single-unit recording
- MeSH terms
- Carbon Fiber, Animals, Astrocytes, Carbon, Cell Count, Electrodes, Implanted, Microcomputers, Microelectrodes, Motor Cortex, Neurons, Silicon, Microglia, Rats, Electrophysiological Phenomena, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review