The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Open accessAbstract
OBJECTIVE: Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. APPROACH: Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. MAIN RESULTS: Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. SIGNIFICANCE: This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“several strategies for minimizing trauma and the inflammatory responses have been investigated, for example, the reduction of the cross-sectional area of the electrodes (Seymour and Kipke, 2007) and the use of more flexible and soft materials that better match the properties of the surrounding tissue”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Patel et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
Paxinos, G., & Watson, C. (1983) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 28,585
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., WATSON, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,514
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Neuron-type-specific signals for reward and punishment in the ventral tegmental area
Cohen, J. Y., Haesler, S., Vong, L., Lowell, B. B., & Uchida, N. (2012) · Nature · doi:10.1038/nature10754 · Cited by 1,318
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Research works printed but not linked: 2
- 2011, 10.1520/F1980-07R11 · DOI
- Kozai, 2014, Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes, Biomaterials, 35, 9255, 10.1016/j.biomaterials.2014.07.039 · DOI · Paper page
Cited by
Sorted by citations
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Self-citationPark, S., Yuk, H., Zhao, R., Yim, Y. S., Woldeghebriel, E. W., Kang, J., Canales, A., Fink, Y., Choi, G. B., Zhao, X., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23802-9 · Cited by 312
Next-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 214
Self-citationMassively parallel microwire arrays integrated with CMOS chips for neural recording
Obaid, A., Hanna, M.-E., Wu, Y., Köllő, M., Rácz, R., Angle, M. R., Müller, J., Brackbill, N., Wray, W., Franke, F., et al. (2020) · Science Advances · doi:10.1126/sciadv.aay2789 · Cited by 201
Neurohybrid Memristive CMOS-Integrated Systems for Biosensors and Neuroprosthetics
Mikhaylov, A. N., Pimashkin, A. S., Pigareva, Y., Gerasimova, S. A., Gryaznov, E. G., Shchanikov, S., Zuev, A. D., Talanov, M. O., Lavrov, I. A., Demin, V. A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00358 · Cited by 189
Slow insertion of silicon probes improves the quality of acute neuronal recordings
Fiáth, R., Márton, A. L., Mátyás, F., Pinke, D., Márton, G., Tóth, K., & Ulbert, I. (2019) · Scientific Reports · doi:10.1038/s41598-018-36816-z · Cited by 168
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 150
Michelson, N. J., Vazquez, A. L., Eles, J. R., Salatino, J. W., Purcell, E. K., Williams, J. J., Cui, X. T., & Kozai, T. D. Y. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9dae · Cited by 126
Self-citationFlexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G. Z. J., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 135
Guidelines to Study and Develop Soft Electrode Systems for Neural Stimulation
Schiavone, G., Kang, X., Fallegger, F., Gandar, J., Courtine, G., & Lacour, S. P. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.010 · Cited by 125
Eles, J. R., Vazquez, A. L., Snyder, N. R., Lagenaur, C. F., Murphy, M. C., Kozai, T. D. Y., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.054 · Cited by 117
Self-citationNason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Self-citationA Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 109
Multifunctional Fibers as Tools for Neuroscience and Neuroengineering
Canales, A., Park, S., Kilias, A., & Anikeeva, P. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00558 · Cited by 103
Zeng, Q., & Huang, Z. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301223 · Cited by 104
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Open source silicon microprobes for high throughput neural recording
Yang, L., Lee, K., Villagracia, J., & Masmanidis, S. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab581a · Cited by 93
Recent development of implantable and flexible nerve electrodes
Shi, Y., Liu, R., He, L. M., Feng, H., Li, Y., & Li, Z. (2020) · Smart Materials in Medicine · doi:10.1016/j.smaim.2020.08.002 · Cited by 93
Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.043 · Cited by 86
Self-citationAmorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
High-density soft bioelectronic fibres for multimodal sensing and stimulation
Khatib, M., Zhao, E. T., Wei, S., Park, J., Abramson, A., Bishop, E. S., Thomas, A.-L. A., Chen, C.-H., Emengo, P. O., Xu, C., et al. (2025) · Nature · doi:10.1038/s41586-025-09481-2 · Cited by 91
Cody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87
Self-citationSharafkhani, N., Kouzani, A. Z., Adams, S. D., Long, J. M., Lissorgues, G., Rousseau, L., & Orwa, J. O. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109388 · Cited by 86
Electrode Materials for Chronic Electrical Microstimulation
Zheng, X. S., Tan, C., Castagnola, E., & Cui, X. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100119 · Cited by 90
Sung, C., Jeon, W., Nam, K. S., Kim, Y., Butt, H., & Park, S. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00872a · Cited by 87
The State of the NIH BRAIN Initiative
Koroshetz, W. J., Gordon, J. A., Adams, A. B., Beckel-Mitchener, A. C., Churchill, J. D., Farber, G. K., Freund, M. P., Gnadt, J., Hsu, N. S., Langhals, N. B., et al. (2018) · Journal of Neuroscience · doi:10.1523/jneurosci.3174-17.2018 · Cited by 80
Carbon-based neural electrodes: promises and challenges
Devi, M., Vomero, M., Fuhrer, E., Castagnola, E., Gueli, C., Nimbalkar, S., Hirabayashi, M., Kassegne, S., Stieglitz, T., & Sharma, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1e45 · Cited by 82
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
The “sewing machine” for minimally invasive neural recordingPreprint
Hanson, T., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 68
Advances in Carbon-Based Microfiber Electrodes for Neural Interfacing
Hejazi, M., Tong, W., Ibbotson, M. R., Prawer, S., & Garrett, D. J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.658703 · Cited by 77
A comparison of insertion methods for surgical placement of penetrating neural interfaces
Thielen, B., & Meng, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf6f2 · Cited by 78
Welle, E. J., Patel, P. R., Woods, J. E., Petrossians, A., della Valle, E., Vega-Medina, A., Richie, J. M., Cai, D., Weiland, J. D., & Chestek, C. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8343 · Cited by 68
Self-citationSoft pin-shaped dry electrode with bristles for EEG signal measurements
Gao, K., Yang, H.-J., Wang, X., Yang, B. T., & Liu, J. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.09.045 · Cited by 66
Interfacing with the Brain: How Nanotechnology Can Contribute
Ahmed, A. A. A., Alegret, N., Almeida, B., Álvarez‐Puebla, R. A., Andrews, A. M., Ballerini, L., Barrios‐Capuchino, J. J., Becker, C., Blick, R. H., Bonakdar, S., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c10525 · Cited by 71
Hejazi, M. A., Tong, W., Stacey, A. D., Soto-Breceda, A., Ibbotson, M. R., Yunzab, M., Maturana, M. I., Almasi, A., Jung, Y. J., Sun, S. H., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119648 · Cited by 66
Ganji, M., Hossain, L., Tanaka, A., Thunemann, M., Halgren, E., Gilja, V., Devor, A., & Dayeh, S. A. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800923 · Cited by 61
Zou, L., Tian, H., Guan, S., Ding, J., Gao, L., Wang, J., & Fang, Y. (2021) · Nature Communications · doi:10.1038/s41467-021-26168-0 · Cited by 60
Jiman, A. A., Ratze, D. C., Welle, E. J., Patel, P. R., Richie, J. M., Bottorff, E. C., Seymour, J. P., Chestek, C. A., & Bruns, T. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72512-7 · Cited by 57
Self-citationPatel, P. R., Popov, P., Caldwell, C. M., Welle, E. J., Egert, D., Pettibone, J. R., Roossien, D. H., Becker, J. B., Berke, J. D., Chestek, C. A., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb1f6 · Cited by 57
Self-citation64-Channel Carbon Fiber Electrode Arrays for Chronic Electrophysiology
Guitchounts, G., & Cox, D. (2020) · Scientific Reports · doi:10.1038/s41598-020-60873-y · Cited by 52
Novel diamond shuttle to deliver flexible neural probe with reduced tissue compression
Na, K., Sperry, Z. J., Lu, J., Vöröslakos, M., Parizi, S. S., Bruns, T. M., Yoon, E., & Seymour, J. P. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0149-z · Cited by 51
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 51
Self-citationNano-Architectural Approaches for Improved Intracortical Interface Technologies
Kim, Y., Meade, S. M., Chen, K., He, F., Rayyan, J., Hess‐Dunning, A., & Ereifej, E. S. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00456 · Cited by 56
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Self-citationEngineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 54
Autotaxin and lysophospholipids in rheumatoid arthritis.
Bourgoin, S. G., & Zhao, C. (2010) · PubMed · Cited by 49
Lim, J., Moon, E., Barrow, M., Nason, S. R., Patel, P. R., Patil, P. G., Oh, S., Lee, I., Kim, H.-S., Sylvester, D., et al. (2020) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc19947.2020.9063005 · Cited by 49
Self-citationPhysiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 47
Yan, D., Jiman, A. A., Bottorff, E. C., Patel, P. R., Meli, D., Welle, E. J., Ratze, D. C., Havton, L. A., Chestek, C. A., Kemp, S. W. P., et al. (2022) · Small · doi:10.1002/smll.202200311 · Cited by 44
Self-citationEles, J. R., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119767 · Cited by 44
Self-citationCarbon microelectrodes with customized shapes for neurotransmitter detection: A review
Shao, Z., Chang, Y., & Venton, B. J. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340165 · Cited by 42
Fernández, E., Alfaro, A., & González-López, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00681 · Cited by 35
Thompson, C. H., Riggins, T. E., Patel, P. R., Chestek, C. A., Li, W., & Purcell, E. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7030 · Cited by 38
Self-citationStieglitz, T. (2019) · Neuroethics · doi:10.1007/s12152-019-09406-7 · Cited by 42
Toward Nontransient Silk Bioelectronics: Engineering Silk Fibroin for Bionic Links
Patil, A. C., Xiong, Z., & Thakor, N. V. (2020) · Small Methods · doi:10.1002/smtd.202000274 · Cited by 37
Lim, J., Lee, J., Moon, E., Barrow, M., Atzeni, G., Letner, J. G., Costello, J. T., Nason, S. R., Patel, P. R., Sun, Y., et al. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3141688 · Cited by 38
Self-citationCarbon fiber electrodes for intracellular recording and stimulation
Huan, Y., Gill, J. P., Fritzinger, J. B., Patel, P. R., Richie, J. M., della Valle, E., Weiland, J. D., Chestek, C. A., & Chiel, H. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3dd7 · Cited by 35
Self-citationShoffstall, A. J., Ecker, M., Danda, V. R., Joshi‐Imre, A., Stiller, A. M., Yu, M. H., Paiz, J. E., Mancuso, E., Bedell, H. W., Voit, W., et al. (2018) · Micromachines · doi:10.3390/mi9100486 · Cited by 35
Bioinspired materials and systems for neural interfacing
Shoffstall, A. J., & Capadona, J. R. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.05.002 · Cited by 34
A soft, high-density neuroelectronic array
Seo, K. J., Hill, M., Ryu, J., Chiang, C., Rachinskiy, I., Qiang, Y., Jang, D., Trumpis, M., Wang, C., Viventi, J., et al. (2023) · npj Flexible Electronics · doi:10.1038/s41528-023-00271-2 · Cited by 33
The future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 33
Self-citationAll-Diamond Microfiber Electrodes for Neurochemical Analysis
Rusinek, C. A., Guo, Y., Rechenberg, R., Becker, M., Purcell, E. K., Verber, M., McKinney, C., & Li, W. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0141812jes · Cited by 31
Bioinspired flexible electronics for seamless neural interfacing and chronic recording
Li, H., Wang, J., & Fang, Y. Z. (2020) · Nanoscale Advances · doi:10.1039/d0na00323a · Cited by 31
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 34
Robbins, E. M., Castagnola, E., & Cui, X. T. (2021) · iScience · doi:10.1016/j.isci.2022.104845 · Cited by 31
Stocking, K. C., Vazquez, A. L., & Kozai, T. D. Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889832 · Cited by 29
Self-citationNordin, A. D., Rymer, W. Z., Biewener, A. A., Schwartz, A. B., Chen, D., & Horak, F. B. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0298-y · Cited by 32
Longitudinal neural and vascular structural dynamics produced by chronic microelectrode implantation
Welle, C. G., Gao, Y., Ye, M., Lozzi, A., Boretsky, A. R., Abliz, E., & Hammer, D. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119831 · Cited by 27
Sharpened and Mechanically Durable Carbon Fiber Electrode Arrays for Neural Recording
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3082056 · Cited by 29
Self-citationObaid, A., Wu, Y., Hanna, M., Nix, W. D., Ding, J., & Melosh, N. A. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/454520 · Cited by 30
Nicolai, E. N., Michelson, N. J., Settell, M. L., Hara, S. A., Trevathan, J. K., Asp, A. J., Stocking, K. C., Luján, J. L., Kozai, T. D. Y., & Ludwig, K. A. (2018) · Micromachines · doi:10.3390/mi9100494 · Cited by 26
Self-citationGhazavi, A., Maeng, J., Black, M., Salvi, S., & Cogan, S. F. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab52ab · Cited by 28
Obaid, A., Hanna, M.-E., Huang, S.-W., Hu, Y.-T., Jáidar, O., Nix, W. D., Ding, J., Melosh, N. A., & Wu, Y. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2529147123 · Cited by 26
Meunier, C. J., Denison, J. D., McCarty, G. S., & Sombers, L. A. (2020) · Langmuir · doi:10.1021/acs.langmuir.9b03941 · Cited by 28
Hyakumura, T., Robles, U. A. A., Duan, W., Villalobos, J., Adams, W. K., Poole-Warren, L. A., & Fallon, J. B. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.761525 · Cited by 26
The History and Horizons of Microscale Neural Interfaces
Kozai, T. D. Y. (2018) · Micromachines · doi:10.3390/mi9090445 · Cited by 29
Self-citationInsertion mechanics of amorphous SiC ultra-micro scale neural probes
Geramifard, N., Dousti, B., Nguyen, C. K., Abbott, J., Cogan, S. F., & Varner, V. D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5bf4 · Cited by 24
Fiáth, R., Hofer, K. T., Csikós, V., Horváth, D., Nánási, T., Tóth, K., Pothof, F., Böhler, C., Asplund, M., Ruther, P., et al. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0154 · Cited by 25
Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad36e1 · Cited by 24
Self-citationHermann, J. K., Lin, S., Soffer, A., Wong, C., Ali, A., Chang, J. B., Sunil, S., Sudhakar, S., Tomaszewski, W. H., Protasiewicz, G., et al. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00113 · Cited by 23
Lee, Y., Kong, C., Chang, J. W., & Jun, S. B. (2019) · Journal of Korean Medical Science · doi:10.3346/jkms.2019.34.e24 · Cited by 23
Cho, W., Liu, F., Hendrix, A., McCray, B., Asrat, T., CONNAUGHTON, V. P., & Zestos, A. G. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/aba33d · Cited by 22
Electrodeposited Platinum Iridium Enables Microstimulation With Carbon Fiber Electrodes
della Valle, E., Koo, B., Patel, P. R., Whitsitt, Q. A., Purcell, E. K., Chestek, C. A., & Weiland, J. D. (2021) · Frontiers in Nanotechnology · doi:10.3389/fnano.2021.782883 · Cited by 21
Self-citationLifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 22
Chen, L., Hartner, J. P., Dong, T., Li, A. D. R., Watson, B. O., & Shih, A. J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3070781 · Cited by 21
Carbon-Based Fiber Materials as Implantable Depth Neural Electrodes
Fu, X., Li, G., Niu, Y., Xu, J., Wang, P., Zhou, Z., Ye, Z., Liu, X., Xu, Z. J., Yang, Z., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.771980 · Cited by 22
Hejazi, M. A., Tong, W., Stacey, A. D., Sun, S. H., Yunzab, M., Almasi, A., Jung, Y. J., Hamish Meffin, A., Fox, K. E., Edalati, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202006101 · Cited by 21
Integrated optoelectronic microprobes
Rudmann, L., Alt, M. T., Vajari, D. A., & Stieglitz, T. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.010 · Cited by 20
Penetrating glassy carbon neural electrode arrays for brain-machine interfaces
Chen, B., Zhang, B., Chen, C., Hu, J., Qi, J., He, T., Tian, P. W., Zhang, X., Ni, G., & Cheng, M. M. (2020) · Biomedical Microdevices · doi:10.1007/s10544-020-00498-0 · Cited by 21
Astro, V., Alowaysi, M., Fiacco, E., Saera-Vila, A., Cardona‐Londoño, K. J., Cigliano, R. A., & Adamo, A. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.801597 · Cited by 20
Emerging Penetrating Neural Electrodes: In Pursuit of Large Scale and Longevity
Luan, L., Yin, R., Zhu, H., & Xie, C. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-090622-050507 · Cited by 23
Ledo, A., Lourenço, C. F., Laranjinha, J. A. N., Gerhardt, G. A., & Barbosa, R. M. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.018 · Cited by 20
Quantitative simulation of extracellular single unit recording from the surface of cortex
Hill, M., Rios, E., Sudhakar, S., Roossien, D. H., Caldwell, C. M., Cai, D., Ahmed, O. J., Lempka, S. F., & Chestek, C. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aacdb8 · Cited by 19
Self-citationEvaluation of a conducting elastomeric composite material for intramuscular electrode application
Zheng, X. S., Griffith, A. Y., Chang, E., Looker, M. J., Fisher, L. E., Clapsaddle, B. J., & Cui, X. T. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.021 · Cited by 18
Ravagli, E., Mastitskaya, S., Thompson, N., Welle, E. J., Chestek, C. A., Aristovich, K. Y., & Holder, D. S. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109140 · Cited by 19
Self-citationZhang, H., Vecchio, D. A., Emre, A. E., Rahmani, S., Cheng, C., Zhu, J. G., Misra, A. C., Lahann, J., & Kotov, N. A. (2021) · MRS Bulletin · doi:10.1557/s43577-021-00071-x · Cited by 22
Self-citationdella Valle, E., Welle, E. J., Chestek, C. A., & Weiland, J. D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac20bb · Cited by 19
Self-citationSpatial Transcriptomics as a Novel Approach to Redefine Electrical Stimulation Safety
Whitsitt, Q. A., Koo, B., Çelik, M. E., Evans, B. M., Weiland, J. D., & Purcell, E. K. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.937923 · Cited by 18
Metadata
- Authors
- Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A.
- Affiliations
- University of Michigan (US)
- University of Pittsburgh (US)
- Corresponding author
- Patel, Paras R
- Zhang, Huanan
- Robbins, Matthew T
- Nofar, Justin B
- Marshall, Shaun P
- Kobylarek, Michael J
- Kozai, Takashi D Y
- Kotov, Nicholas A
- Chestek, Cynthia A
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-10-05
- Volume
- 13
- Issue
- 6
- Pages
- 066002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC5118062
- OpenAlex
- W2529123936
- Cited by
- 204
- References
- 77
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 17 · 2023: 18 · 2022: 16 · 2021: 34 · 2020: 34 · 2019: 24 · 2018: 24 · 2017: 9 · 2016: 2
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- McKnight Foundation
- National Institute of Neurological Disorders and Stroke (1R01NS094396)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- chronic neural recording, electrode stability, PEDOT coating, accelerated aging, glial scar, silicon electrodes, single-unit recording
- MeSH terms
- Carbon Fiber, Animals, Astrocytes, Carbon, Cell Count, Electrodes, Implanted, Microcomputers, Microelectrodes, Motor Cortex, Neurons, Silicon, Microglia, Rats, Electrophysiological Phenomena, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review