The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex
Open accessAbstract
The viability of chronic neural microelectrodes for electrophysiological recording and stimulation depends on several factors, including the encapsulation of the implant by a reactive tissue response. We postulate that mechanical strains induced around the implant site may be one of the leading factors responsible for the sustained tissue response in chronic implants. The objectives of this study were to develop a finite-element model of the probe-brain tissue interface and analyze the effects of tethering forces, probe-tissue adhesion and stiffness of the probe substrate on the interfacial strains induced around the implant site. A 3D finite-element model of the probe-brain tissue microenvironment was developed and used to simulate interfacial strains created by 'micromotion' of chronically implanted microelectrodes. Three candidate substrates were considered: (a) silicon, (b) polyimide and (c) a hypothetical 'soft' material. Simulated tethering forces resulted in elevated strains both at the tip and at the sharp edges of the probe track in the tissue. The strain fields induced by a simulated silicon probe were similar to those induced by a simulated polyimide probe, albeit at higher absolute values for radial tethering forces. Simulations of poor probe-tissue adhesion resulted in elevated strains at the tip and delamination of the tissue from the probe. A tangential tethering force results in 94% reduction in the strain value at the tip of the polyimide probe track in the tissue, whereas the simulated 'soft' probe induced two orders of magnitude smaller values of strain compared to a simulated silicon probe. The model results indicate that softer substrates reduce the strain at the probe-tissue interface and thus may also reduce tissue response in chronic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the polyimide material demonstrated a 94% reduction in applied strain to the surrounding tissue, while strain with the theoretical 6 MPa material was reduced by two orders of magnitude.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [169]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Mechanical Behavior of Materials
Hosford, W. F. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810930 · Cited by 1,795
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationRegional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 636
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 636
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Constitutive modelling of brain tissue: Experiment and theory
Miller, K., & Chinzei, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00092-4 · Cited by 525
Research works printed but not linked: 5
- Stensaas S S, 1976, Acta Neuropathol., 35, 187
- Muthuswamy J, 2003, 25th Annual Int. Conf. of EMBS
- Uwe Meyer J, 1996, 18th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
- Edell D J Kuzma J Petraitis D, 1996, 18th Annual Int. Conference of the IEEE Engineering in Medicine and Biology Society
- Hetke J F, 2003, 25th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
Cited by
Sorted by citations
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A. G. A., Zwierstra, M. J., Hanna, P. C., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 828
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Self-citationLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Metadata
- Authors
- Subbaroyan, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-10-11
- Volume
- 2
- Issue
- 4
- Pages
- 103-113
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1982562840
- Cited by
- 368
- References
- 46
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 14 · 2023: 17 · 2022: 15 · 2021: 21 · 2020: 27 · 2019: 19 · 2018: 29 · 2017: 15 · 2016: 24 · 2015: 23 · 2014: 20 · 2013: 24 · 2012: 14
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- National Aeronautics and Space Administration
- National Institutes of Health
- National Nanotechnology Coordinating Office
- National Institute of Biomedical Imaging and Bioengineering (P41 EB-00 230-10)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- implantable microelectrodes, cerebral cortex, interfacial strain, silicon probes, tissue encapsulation, electrophysiological recording, neurostimulation
- MeSH terms
- Animals, Biomechanical Phenomena, Cerebral Cortex, Computer Simulation, Elasticity, Electrodes, Implanted, Humans, Microelectrodes, Models, Neurological, Motion, Physical Stimulation, Stress, Mechanical, Finite Element Analysis, Mechanotransduction, Cellular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review