The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex
Open accessAbstract
The viability of chronic neural microelectrodes for electrophysiological recording and stimulation depends on several factors, including the encapsulation of the implant by a reactive tissue response. We postulate that mechanical strains induced around the implant site may be one of the leading factors responsible for the sustained tissue response in chronic implants. The objectives of this study were to develop a finite-element model of the probe-brain tissue interface and analyze the effects of tethering forces, probe-tissue adhesion and stiffness of the probe substrate on the interfacial strains induced around the implant site. A 3D finite-element model of the probe-brain tissue microenvironment was developed and used to simulate interfacial strains created by 'micromotion' of chronically implanted microelectrodes. Three candidate substrates were considered: (a) silicon, (b) polyimide and (c) a hypothetical 'soft' material. Simulated tethering forces resulted in elevated strains both at the tip and at the sharp edges of the probe track in the tissue. The strain fields induced by a simulated silicon probe were similar to those induced by a simulated polyimide probe, albeit at higher absolute values for radial tethering forces. Simulations of poor probe-tissue adhesion resulted in elevated strains at the tip and delamination of the tissue from the probe. A tangential tethering force results in 94% reduction in the strain value at the tip of the polyimide probe track in the tissue, whereas the simulated 'soft' probe induced two orders of magnitude smaller values of strain compared to a simulated silicon probe. The model results indicate that softer substrates reduce the strain at the probe-tissue interface and thus may also reduce tissue response in chronic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the polyimide material demonstrated a 94% reduction in applied strain to the surrounding tissue, while strain with the theoretical 6 MPa material was reduced by two orders of magnitude.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [169]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Mechanical Behavior of Materials
Hosford, W. F. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810930 · Cited by 1,795
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationRegional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 636
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 636
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Constitutive modelling of brain tissue: Experiment and theory
Miller, K., & Chinzei, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00092-4 · Cited by 525
Mechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G. J., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 484
Self-citationFactors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364
Self-citationDeformation and fracture of small silicon crystals
Pearson, G. L., Read, W. T., & Feldmann, W. L. (1957) · Acta Metallurgica · doi:10.1016/0001-6160(57)90164-5 · Cited by 300
Age-Dependent Changes in Material Properties of the Brain and Braincase of the Rat
Gefen, A., Gefen, N., Zhu, Q., Raghupathi, R., & Margulies, S. S. (2003) · Journal of Neurotrauma · doi:10.1089/089771503770802853 · Cited by 299
A multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 285
Zhang, M., Zheng, Y., & Mak, A. F. T. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00017-9 · Cited by 282
Shear Properties of Human Brain Tissue
Donnelly, B. R., & Medige, J. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798289 · Cited by 239
Reassessment of brain elasticity for analysis of biomechanisms of hydrocephalus
Taylor, Z. A., & Miller, K. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.11.027 · Cited by 235
3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T. J., Mabuchi, K., & Fujita, H. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 221
Chronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y. T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 215
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Peter Norlin, A., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Histopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 177
Metz, S., Bertsch, A., Bertrand, D., & Renaud, P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.021 · Cited by 167
Mechanical properties of tissues of the nervous system
Ommaya, A. K. (1968) · Journal of Biomechanics · doi:10.1016/0021-9290(68)90015-8 · Cited by 164
High density interconnects and flexible hybrid assemblies for active biomedical implants
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.938305 · Cited by 145
Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances
Johnson, M. D., Otto, K. J., & Kipke, D. R. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847373 · Cited by 131
Self-citationStieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125
Brands, D. W. A., Peters, G. G., & Bovendeerd, P. H. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00243-4 · Cited by 115
Tissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 92
The reaction of the cerebral cortex to chronically implanted plastic needles.
Stensaas, S. S., & Stensaas, L. J. (1976) · PubMed · Cited by 88
Flexible biomedical microdevices with double-sided electrode arrangements for neural applications
Stieglitz, T. (2001) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00520-9 · Cited by 75
Quantitative analysis of methods for reducing physiological brain pulsations
Britt, R. H., & Rossi, G. T. (1982) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(82)90085-1 · Cited by 64
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
34th Annual Meeting of Society for Neuroscience
Calzavara, R., Mailly, P., Bennett, S. R., Kim, K. J., Yung, Y. W., & Haber, S. N. (2004) · HAL · Cited by 40
(2001) · The International Journal of Artificial Organs · doi:10.1177/039139880102400822 · Cited by 40
3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording
Hetke, J. F., Williams, J. C., Pellinen, D. S., Vetter, R. J., & Kipke, D. R. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196787 · Cited by 39
Self-citationA shuttered probe with in-line flowmeters for chronic in-vivo drug delivery
Papageorgiou, D., Bledsoe, S. C., Gulari, M. N., Hetke, J. F., Anderson, D. J., & Wise, K. D. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2001.906516 · Cited by 33
Microactuated neural probes to compensate for brain micromotion
Muthuswamy, J., Gilletti, A., Jain, T., & Okandan, M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279819 · Cited by 29
Koeneman, B. A., Lee, K., Singh, A., He, J., Raupp, G. B., Panitch, A., & Capco, D. G. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.033 · Cited by 18
Using region-of-interest based finite element modelling for brain-surgery simulation
Hansen, K. V., & Larsen, O. V. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056214 · Cited by 11
Chemical sensing capability of MEMS implantable multichannel neural microelectrode arrays
Johnson, M. D., Williams, J. C., Holecko, M. M., & Kipke, D. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280858 · Cited by 10
Self-citationChronically implantable neural information transducers
Meyer, J.-U., Edell, D. J., Rutten, W. L. C., Pine, J., & Edell, D. J. (1996) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.646468 · Cited by 10
Tomorrow's implantable electronic systems
Edell, D. J. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.646483 · Cited by 4
Research works printed but not linked: 5
- Stensaas S S, 1976, Acta Neuropathol., 35, 187
- Muthuswamy J, 2003, 25th Annual Int. Conf. of EMBS
- Uwe Meyer J, 1996, 18th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
- Edell D J Kuzma J Petraitis D, 1996, 18th Annual Int. Conference of the IEEE Engineering in Medicine and Biology Society
- Hetke J F, 2003, 25th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
Cited by
Sorted by citations
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A. G. A., Zwierstra, M. J., Hanna, P. C., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 828
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Self-citationLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Metadata
- Authors
- Subbaroyan, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-10-11
- Volume
- 2
- Issue
- 4
- Pages
- 103-113
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1982562840
- Cited by
- 368
- References
- 46
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 14 · 2023: 17 · 2022: 15 · 2021: 21 · 2020: 27 · 2019: 19 · 2018: 29 · 2017: 15 · 2016: 24 · 2015: 23 · 2014: 20 · 2013: 24 · 2012: 14
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- National Aeronautics and Space Administration
- National Institutes of Health
- National Nanotechnology Coordinating Office
- National Institute of Biomedical Imaging and Bioengineering (P41 EB-00 230-10)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- implantable microelectrodes, cerebral cortex, interfacial strain, silicon probes, tissue encapsulation, electrophysiological recording, neurostimulation
- MeSH terms
- Animals, Biomechanical Phenomena, Cerebral Cortex, Computer Simulation, Elasticity, Electrodes, Implanted, Humans, Microelectrodes, Models, Neurological, Motion, Physical Stimulation, Stress, Mechanical, Finite Element Analysis, Mechanotransduction, Cellular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›