Selection and parameterization of cortical neurons for neuroprosthetic control
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
When designing neuroprosthetic interfaces for motor function, it is crucial to have a system that can extract reliable information from available neural signals and produce an output suitable for real life applications. Systems designed to date have relied on establishing a relationship between neural discharge patterns in motor cortical areas and limb movement, an approach not suitable for patients who require such implants but who are unable to provide proper motor behavior to initially tune the system. We describe here a method that allows rapid tuning of a population vector-based system for neural control without arm movements. We trained highly motivated primates to observe a 3D center-out task as the computer played it very slowly. Based on only 10-12 s of neuronal activity observed in M1 and PMd, we generated an initial mapping between neural activity and device motion that the animal could successfully use for neuroprosthetic control. Subsequent tunings of the parameters led to improvements in control, but the initial selection of neurons and estimated preferred direction for those cells remained stable throughout the remainder of the day. Using this system, we have observed that the contribution of individual neurons to the overall control of the system is very heterogeneous. We thus derived a novel measure of unit quality and an indexing scheme that allowed us to rate each neuron's contribution to the overall control. In offline tests, we found that fewer than half of the units made positive contributions to the performance. We tested this experimentally by having the animals control the neuroprosthetic system using only the 20 best neurons. We found that performance in this case was better than when the entire set of available neurons was used. Based on these results, we believe that, with careful task design, it is feasible to parameterize control systems without any overt behaviors and that subsequent control system design will be enhanced with cautious unit selection. These improvements can lead to systems demanding lower bandwidth and computational power, and will pave the way for more feasible clinical systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Ascertaining the Importance of Neurons to Develop Better Brain-Machine Interfaces
Sanchez, J. C., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., Harris, J. G., & Principe, J. C. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827061 · Cited by 111
Cited by
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Metadata
- Authors
- Wahnoun, R., He, J., & Tillery, S. I. H.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-05-16
- Volume
- 3
- Issue
- 2
- Pages
- 162-171
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1967425188
- Cited by
- 122
- References
- 4
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selection and parameterization of cortical neurons for neuroprosthetic control. https://app.cochat.ai/papers/10.1088/1741-2560/3/2/010
- The paper
- Wahnoun, R., He, J., & Tillery, S. I. H. (2006). Selection and parameterization of cortical neurons for neuroprosthetic control. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/3/2/010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.