The DOI matches its Crossref record; 49 of the 52 references it cites were found in a registry or an index.

Toward a self-deploying shape memory polymer neuronal electrode

Abstract

The widespread application of neuronal probes for chronic recording of brain activity and functional stimulation has been slow to develop partially due to long-term biocompatibility problems with existing metallic and ceramic probes and the tissue damage caused during probe insertion. Stiff probes are easily inserted into soft brain tissue but cause astrocytic scars that become insulating sheaths between electrodes and neurons. In this communication, we explore the feasibility of a new approach to the composition and implantation of chronic electrode arrays. We demonstrate that softer polymer-based probes can be inserted into the olfactory bulb of a mouse and that slow insertion of the probes reduces astrocytic scarring. We further present the development of a micromachined shape memory polymer probe, which provides a vehicle to self-deploy an electrode at suitably slow rates and which can provide sufficient force to penetrate the brain. The deployment rate and composition of shape memory polymer probes can be tailored by polymer chemistry and actuator design. We conclude that it is feasible to fabricate shape memory polymer-based electrodes that would slowly self-implant compliant conductors into the brain, and both decrease initial trauma resulting from implantation and enhance long-term biocompatibility for long-term neuronal measurement and stimulation.

Overview

Integrity signals

Registry

Crossref · 10.1088/1741-2560/3/4/l02

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 52 references

Research works printed but not linked: 1

  1. 10.1073/pnas.031571398 · doi:10.1073/pnas.031571398 · Paper page

Cited by

See all 113

Metadata

Authors
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D.
Affiliations
  • University of Colorado Denver (US)
  • University of Colorado Boulder (US)
  • Georgia Institute of Technology (US)
Venue
Journal of Neural Engineering
Published
2006-10-30
Volume
3
Issue
4
Pages
L23-L30
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2047924253
Cited by
113
References
52
Citations by year
2025: 6 · 2024: 2 · 2023: 4 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 9 · 2018: 4 · 2017: 8 · 2016: 5 · 2015: 9 · 2014: 9 · 2013: 8 · 2012: 9
FWCI
1.52
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute on Deafness and Other Communication Disorders (DC-00566, R01DC000566)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Social Sciences › Education › Undergraduate Neuroscience Education and Research
Keywords
shape memory polymers, chronic neural recording, neurostimulation, biocompatibility
MeSH terms
Algorithms, Animals, Brain, Electrodes, Implanted, Equipment Design, Glial Fibrillary Acidic Protein, Gliosis, Immunohistochemistry, Male, Microscopy, Electron, Scanning, Neurons, Polymers, Temperature, Entropy, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Toward a self-deploying shape memory polymer neuronal electrode. https://app.cochat.ai/papers/10.1088/1741-2560/3/4/l02
The paper
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006). Toward a self-deploying shape memory polymer neuronal electrode. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/3/4/l02

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.