Toward a self-deploying shape memory polymer neuronal electrode
Abstract
The widespread application of neuronal probes for chronic recording of brain activity and functional stimulation has been slow to develop partially due to long-term biocompatibility problems with existing metallic and ceramic probes and the tissue damage caused during probe insertion. Stiff probes are easily inserted into soft brain tissue but cause astrocytic scars that become insulating sheaths between electrodes and neurons. In this communication, we explore the feasibility of a new approach to the composition and implantation of chronic electrode arrays. We demonstrate that softer polymer-based probes can be inserted into the olfactory bulb of a mouse and that slow insertion of the probes reduces astrocytic scarring. We further present the development of a micromachined shape memory polymer probe, which provides a vehicle to self-deploy an electrode at suitably slow rates and which can provide sufficient force to penetrate the brain. The deployment rate and composition of shape memory polymer probes can be tailored by polymer chemistry and actuator design. We conclude that it is feasible to fabricate shape memory polymer-based electrodes that would slowly self-implant compliant conductors into the brain, and both decrease initial trauma resulting from implantation and enhance long-term biocompatibility for long-term neuronal measurement and stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Programming of the 1.5-mm long device has been conducted at 50°C, which is clearly below the polymers T g (70°C), but also clearly above body temperature, resulting in very slow movement of the probe tip at 37°C (Figure 8).”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [121]
In the citing paper
“In contrast to immediate shape recovery, which is useful in several applications, slow shape recovery has been realized with a neuronal probe microactuator from an amorphous SMP [121].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [121]
Citations
Cites
Wayman, C. M., & 大塚, 和. (1998) · Cambridge University Press eBooks · Cited by 3,134
Biodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Reactive Astrocytes Protect Tissue and Preserve Function after Spinal Cord Injury
Faulkner, J. R., Herrmann, J. E., Woo, M. J., Tansey, K. E., Doan, N. B., & Sofroniew, M. V. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3547-03.2004 · Cited by 1,598
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Review of Current Evidence for Apoptosis After Spinal Cord Injury
BEATTIE, M. S., FAROOQUI, A. A., & BRESNAHAN, J. C. (2000) · Journal of Neurotrauma · doi:10.1089/neu.2000.17.915 · Cited by 521
Research works printed but not linked: 1
- 10.1073/pnas.031571398 · doi:10.1073/pnas.031571398 · Paper page
Cited by
Review of progress in shape-memory polymers
Liu, C., Qin, H., & Mather, P. T. (2007) · Journal of Materials Chemistry · doi:10.1039/b615954k · Cited by 1,942
Hu, J., Zhu, Y., Huang, H., & Lu, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.06.001 · Cited by 1,279
A review of stimuli-responsive shape memory polymer composites
Meng, H., & Li, G. (2013) · Polymer · doi:10.1016/j.polymer.2013.02.023 · Cited by 1,190
Stimulus-responsive shape memory materials: a review
Sun, L., Huang, W. M., Ding, Z., Zhao, Y., Wang, C. C., Purnawali, H., & Tang, C. (2012) · Materials & Design · doi:10.1016/j.matdes.2011.04.065 · Cited by 1,105
Shape memory polymers: Past, present and future developments
Hager, M. D., Bode, S., Weber, C., & Schubert, U. S. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2015.04.002 · Cited by 950
Metadata
- Authors
- Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D.
- Affiliations
- University of Colorado Denver (US)
- University of Colorado Boulder (US)
- Georgia Institute of Technology (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-10-30
- Volume
- 3
- Issue
- 4
- Pages
- L23-L30
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2047924253
- Cited by
- 113
- References
- 52
- Citations by year
- 2025: 6 · 2024: 2 · 2023: 4 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 9 · 2018: 4 · 2017: 8 · 2016: 5 · 2015: 9 · 2014: 9 · 2013: 8 · 2012: 9
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Deafness and Other Communication Disorders (DC-00566, R01DC000566)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- shape memory polymers, chronic neural recording, neurostimulation, biocompatibility
- MeSH terms
- Algorithms, Animals, Brain, Electrodes, Implanted, Equipment Design, Glial Fibrillary Acidic Protein, Gliosis, Immunohistochemistry, Male, Microscopy, Electron, Scanning, Neurons, Polymers, Temperature, Entropy, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward a self-deploying shape memory polymer neuronal electrode. https://app.cochat.ai/papers/10.1088/1741-2560/3/4/l02
- The paper
- Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006). Toward a self-deploying shape memory polymer neuronal electrode. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/3/4/l02
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.