An electronic device for artefact suppression in human local field potential recordings during deep brain stimulation
Open accessThe DOI matches its Crossref record.
Abstract
The clinical efficacy of high-frequency deep brain stimulation (DBS) for Parkinson's disease and other neuropsychiatric disorders likely depends on the modulation of neuronal rhythms in the target nuclei. This modulation could be effectively measured with local field potential (LFP) recordings during DBS. However, a technical drawback that prevents LFPs from being recorded from the DBS target nuclei during stimulation is the stimulus artefact. To solve this problem, we designed and developed 'FilterDBS', an electronic amplification system for artefact-free LFP recordings (in the frequency range 2-40 Hz) during DBS. After defining the estimated system requirements for LFP amplification and DBS artefact suppression, we tested the FilterDBS system by conducting experiments in vitro and in vivo in patients with advanced Parkinson's disease undergoing DBS of the subthalamic nucleus (STN). Under both experimental conditions, in vitro and in vivo, the FilterDBS system completely suppressed the DBS artefact without inducing significant spectral distortion. The FilterDBS device pioneers the development of an adaptive DBS system retroacted by LFPs and can be used in novel closed-loop brain-machine interface applications in patients with neurological disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Deep brain stimulation can suppress pathological synchronisation in parkinsonian patients
Eusebio, A., Thevathasan, W., Doyle Gaynor, L., Pogosyan, A., Bye, E., Foltynie, T., Zrinzo, L., Ashkan, K., Aziz, T., & Brown, P. (2011) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2010.217489 · Cited by 412
The Varied Clinical Expressions of Dystonia
Fahn, S. (1984) · Neurologic Clinics · doi:10.1016/s0733-8619(18)31090-9 · Cited by 402
Adaptive deep brain stimulation (aDBS) controlled by local field potential oscillations
Priori, A., Foffani, G., Rossi, L., & Marceglia, S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2012.09.013 · Cited by 331
Self-citationStanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330
Oswal, A., Beudel, M., Zrinzo, L., Limousin, P., Hariz, M., Foltynie, T., Litvak, V., & Brown, P. (2016) · Brain · doi:10.1093/brain/aww048 · Cited by 310
Little, S., & Brown, P. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06650.x · Cited by 268
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“[84] designed “FilterDBS” which is an artifact-free recording system for acquisition of LFPs from the DBS lead positioned in the STN.”
BackgroundMethodGiannicola, G., Marceglia, S., Rossi, L., Mrakic-Sposta, S., Rampini, P., Tamma, F., Cogiamanian, F., Barbieri, S., & Priori, A. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2010.08.011 · Cited by 205
“Monopolar STN-DBS was delivered through contact 1, placed in the optimal functional target as detailed in the foregoing, and differential LFP recordings were acquired between contacts 0 and 2 in the stimulated side through the FilterDBS system (Rossi et al., 2007).”
BackgroundMethodResultSelf-citationClosed-Loop Control of Deep Brain Stimulation: A Simulation Study
Santaniello, S., Fiengo, G., Glielmo, L., & Grill, W. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2081377 · Cited by 202
“sured using the clinically implanted DBS electrode [13], [14], and there is very high correlation between field potentials and”
MethodÖzkurt, T. E., Butz, M., Homburger, M., Elben, S., Vesper, J., Wojtecki, L., & Schnitzler, A. (2011) · Experimental Neurology · doi:10.1016/j.expneurol.2011.02.015 · Cited by 196
Beuter, A., Lefaucheur, J.-P., & Modolo, J. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.01.006 · Cited by 107
“However, electrical stimulation delivered to the brain induces an artifact in the recorded signal, which must be removed for further processing in closed-loop technique (Rossi et al., 2007; Al-Ani et al., 2011; Kent and Grill, 2012).”
On-Demand Control System for Deep Brain Stimulation for Treatment of Intention Tremor
Yamamoto, T., Katayama, Y., Ushiba, J., Yoshino, H., Obuchi, T., Kobayashi, K., Oshima, H., & Fukaya, C. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00521.x · Cited by 90
Belkacem, A. N., Jamil, N., Khalid, S., & Alnajjar, F. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1085173 · Cited by 80
Huang, C.-W., Lai, C.-K., Hung, C.-C., Wu, C.-Y., & Ker, M.-D. (2023) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2023.3254891 · Cited by 16
Equalization for intracortical microstimulation artifact reduction.
Chu, P., Muller, R., Koralek, A., Carmena, J. M., Rabaey, J. M., & Gambini, S. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609483 · Cited by 13
Metadata
- Authors
- Rossi, L., Foffani, G., Marceglia, S., Bracchi, F., Barbieri, S., & Priori, A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-03-13
- Volume
- 4
- Issue
- 2
- Pages
- 96-106
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2025347688
- Cited by
- 131
- References
- 0
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.