Equalization for intracortical microstimulation artifact reduction.
Open accessAbstract
We present a method for decreasing the duration of artifacts present during intra-cortical microstimulation (ICMS) recordings by using techniques developed for digital communications. We replace the traditional monophasic or biphasic current stimulation pulse with a patterned pulse stream produced by a Zero Forcing Equalizer (ZFE) filter after characterizing the artifact as a communications channel. The results find that using the ZFE stimulus has the potential to reduce artifact width by more than 70%. Considerations for the hardware implementation of the equalizer are presented.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In Dura et al. (2012) and Chu et al. (2013), high-frequency short-duration pulses or other specific patterns are adopted for stimulation.
“In Dura et al. (2012) and Chu et al. (2013), high-frequency short-duration pulses or other specific patterns are adopted for stimulation.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Chu et al., 2013
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
A technique for the identification of linear systems
Steiglitz, K., & McBride, L. (1965) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1965.1098181 · Cited by 643 · see citing works
Long-term motor cortex plasticity induced by an electronic neural implant
Andrew, J. O., Mavoori, J., & Fetz, E. E. (2006) · Nature · doi:10.1038/nature05226 · Cited by 454 · see citing works
Stanslaski, S. R., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P. H., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330 · see citing works
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 224 · see citing works
Rossi, L., Foffani, G., Marceglia, S. R. F., Bracchi, F., Barbieri, S., & Priori, A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/010 · Cited by 131 · see citing works
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125 · see citing works
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21 · see citing works
- Authors
- Chu, P., Muller, R., Koralek, A., Carmena, J. M., Rabaey, J. M., & Gambini, S.
- Affiliations
- University of California, Berkeley (US)
- The University of Melbourne (AU)
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Pages
- 245-248
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2049528401
- Cited by
- 13
- References
- 7
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 5 · 2018: 3 · 2015: 1 · 2014: 1
- FWCI
- 1.77
- Type
- conference paper
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- cc-by-nc-nd
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- UC Berkeley (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by-nc-nd)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- intracortical microstimulation, artifact reduction, zero-forcing equalizer, channel modeling
- MeSH terms
- Animals, Humans, Microelectrodes, Artifacts, Deep Brain Stimulation, Rats, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review