Sensorimotor rhythm-based brain–computer interface (BCI): model order selection for autoregressive spectral analysis
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
People can learn to control EEG features consisting of sensorimotor rhythm amplitudes and can use this control to move a cursor in one or two dimensions to a target on a screen. Cursor movement depends on the estimate of the amplitudes of sensorimotor rhythms. Autoregressive models are often used to provide these estimates. The order of the autoregressive model has varied widely among studies. Through analyses of both simulated and actual EEG data, the present study examines the effects of model order on sensorimotor rhythm measurements and BCI performance. The results show that resolution of lower frequency signals requires higher model orders and that this requirement reflects the temporal span of the model coefficients. This is true for both simulated EEG data and actual EEG data during brain-computer interface (BCI) operation. Increasing model order, and decimating the signal were similarly effective in increasing spectral resolution. Furthermore, for BCI control of two-dimensional cursor movement, higher model orders produced better performance in each dimension and greater independence between horizontal and vertical movements. In sum, these results show that autoregressive model order selection is an important determinant of BCI performance and should be based on criteria that reflect system performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879 · cited 4×
“The use of AIC resulted in much lower model order selections than selection based on optimizing r 2 ( Krusienski et al, 2006).”
MethodInfluentialNumerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“The eventual success of BCI research and development depends on improvements in signal acquisition, feature extraction, feature translation, and application development (Wolpaw et al, 2002).”
BackgroundSelf-citationNumerical Recipes--The Art of Scientific Computing.
Fritsch, F. N., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1988) · Mathematics of Computation · doi:10.2307/2007938 · Cited by 4,845
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“…studies over the past two decades indicate that scalp-recorded EEG activity can be the basis for non-muscular communication and control systems, commonly called brain-computer interfaces (BCIs) (Birbaumer et al, 1999; Farwell and Donchin, 1988; Pfurtscheller et al, 1993; Wolpaw et al, 1991).”
BackgroundBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024 · cited 1×
“The standard online protocol, which has been described in previous publications (McFarland et al, 1997; Schalk et al, 2004; Wolpaw and McFarland, 2004), is summarized here.”
MethodSelf-citationDigital Spectral Analysis with Applications.
Porat, B., & Marple, S. L. (1988) · Mathematics of Computation · doi:10.2307/2008605 · Cited by 2,644
Digital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984 · cited 3×
“An additional consideration is that higher model orders may lead to the identification of false spectral peaks (Marple, 1987).”
BackgroundMethodInfluentialDigital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“…studies over the past two decades indicate that scalp-recorded EEG activity can be the basis for non-muscular communication and control systems, commonly called brain-computer interfaces (BCIs) (Birbaumer et al, 1999; Farwell and Donchin, 1988; Pfurtscheller et al, 1993; Wolpaw et al, 1991).”
Background
Cited by
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Self-citationBrain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Self-citationZrenner, C., Desideri, D., Belardinelli, P., & Ziemann, U. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.11.016 · Cited by 451
Chai, R., Naik, G. R., Nguyen, T. N., Ling, S. H., Tran, Y., Craig, A., & Nguyen, H. T. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2532354 · Cited by 250
“This study explores the autoregressive (AR) model as it is an effective tool in EEG feature extraction algorithms, and will be used as a comparison to the PSD method [29]–[31].”
MethodResult(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Toward Brain-Actuated Humanoid Robots: Asynchronous Direct Control Using an EEG-Based BCI
Chae, Y., Jeong, J., & Jo, S. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2201310 · Cited by 211
Zrenner, B., Zrenner, C., Gordon, P. C., Belardinelli, P., McDermott, E. J., Soekadar, S. R., Fallgatter, A. J., Ziemann, U., & Müller-Dahlhaus, F. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.007 · Cited by 175
Brain–computer interface: trend, challenges, and threats
Maiseli, B., Abdalla, A. T., Massawe, L. V., Mbise, M., Mkocha, K., Nassor, N. A., Ismail, M., Michael, J., & Kimambo, S. (2023) · Brain Informatics · doi:10.1186/s40708-023-00199-3 · Cited by 168
Metadata
- Authors
- McFarland, D. J., & Wolpaw, J. R.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2008-04-22
- Volume
- 5
- Issue
- 2
- Pages
- 155-162
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2078707072
- Cited by
- 171
- References
- 31
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.