An online multi-channel SSVEP-based brain–computer interface using a canonical correlation analysis method
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
In recent years, there has been increasing interest in using steady-state visual evoked potential (SSVEP) in brain-computer interface (BCI) systems. However, several aspects of current SSVEP-based BCI systems need improvement, specifically in relation to speed, user variation and ease of use. With these improvements in mind, this paper presents an online multi-channel SSVEP-based BCI system using a canonical correlation analysis (CCA) method for extraction of frequency information associated with the SSVEP. The key parameters, channel location, window length and the number of harmonics, are investigated using offline data, and the result used to guide the design of the online system. An SSVEP-based BCI system with six targets, which use nine channel locations in the occipital and parietal lobes, a window length of 2 s and the first harmonic, is used for online testing on 12 subjects. The results show that the proposed BCI system has a high performance, achieving an average accuracy of 95.3% and an information transfer rate of 58 +/- 9.6 bit min(-1). The positive characteristics of the proposed system are that channel selection and parameter optimization are not required, the possible use of harmonic frequencies, low user variation and easy setup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“The ITR was measured in bits per minute [1].”
MethodStatistical Analysis in Climate Research
Lund, R. B., von Storch, H., & Zwiers, F. W. (2000) · Journal of the American Statistical Association · doi:10.2307/2669798 · Cited by 2,741
Statistical Analysis in Climate Research
Storch, H. V., & Zwiers, F. W. (1999) · Cambridge University Press eBooks · doi:10.1017/cbo9780511612336 · Cited by 2,717
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationDesign and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citationFrequency Recognition Based on Canonical Correlation Analysis for SSVEP-Based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886577 · Cited by 724
Self-citationBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Self-citationControl of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Müller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Brain-Computer Interfacing for Intelligent Systems
Nijholt, A., & Tan, D. (2008) · IEEE Intelligent Systems · doi:10.1109/mis.2008.41 · Cited by 279
Trejo, L. J., Rosipal, R., & Matthews, B. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875578 · Cited by 267
Detection of neural activity in functional MRI using canonical correlation analysis
Friman, O., Cedefamn, J., Lundberg, P., Borga, M., & Knutsson, H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0.co;2-# · Cited by 240
Stimulator selection in SSVEP-based BCI
Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.01.004 · Cited by 192
Visual Spatial Attention Control in an Independent Brain-Computer Interface
Kelly, S. P., Lalor, E. C., Finucane, C., McDarby, G., & Reilly, R. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851510 · Cited by 176
Wu, Z., & Yao, D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/004 · Cited by 78
Kluge, T., & Hartmann, M. (2007) · 2007 3rd International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369700 · Cited by 50
The SSVEP topographic scalp maps by Canonical correlation analysis
Bin, G., Lin, Z., Gao, X., Hong, B., & Gao, S. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650026 · Cited by 20
Self-citation
Cited by
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Enhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Self-citationChen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Metadata
- Authors
- Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-06-03
- Volume
- 6
- Issue
- 4
- Pages
- 046002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2105478324
- Cited by
- 773
- References
- 23
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.