An online multi-channel SSVEP-based brain–computer interface using a canonical correlation analysis method
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
In recent years, there has been increasing interest in using steady-state visual evoked potential (SSVEP) in brain-computer interface (BCI) systems. However, several aspects of current SSVEP-based BCI systems need improvement, specifically in relation to speed, user variation and ease of use. With these improvements in mind, this paper presents an online multi-channel SSVEP-based BCI system using a canonical correlation analysis (CCA) method for extraction of frequency information associated with the SSVEP. The key parameters, channel location, window length and the number of harmonics, are investigated using offline data, and the result used to guide the design of the online system. An SSVEP-based BCI system with six targets, which use nine channel locations in the occipital and parietal lobes, a window length of 2 s and the first harmonic, is used for online testing on 12 subjects. The results show that the proposed BCI system has a high performance, achieving an average accuracy of 95.3% and an information transfer rate of 58 +/- 9.6 bit min(-1). The positive characteristics of the proposed system are that channel selection and parameter optimization are not required, the possible use of harmonic frequencies, low user variation and easy setup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“The ITR was measured in bits per minute [1].”
MethodStatistical Analysis in Climate Research
Lund, R. B., von Storch, H., & Zwiers, F. W. (2000) · Journal of the American Statistical Association · doi:10.2307/2669798 · Cited by 2,741
Statistical Analysis in Climate Research
Storch, H. V., & Zwiers, F. W. (1999) · Cambridge University Press eBooks · doi:10.1017/cbo9780511612336 · Cited by 2,717
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Self-citationDesign and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Self-citationFrequency Recognition Based on Canonical Correlation Analysis for SSVEP-Based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886577 · Cited by 724
Self-citationBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Self-citation
Cited by
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Enhancing Detection of SSVEPs for a High-Speed Brain Speller Using Task-Related Component Analysis
Nakanishi, M., Wang, Y., Chen, X., Wang, Y.-T., Gao, X., & Jung, T.-P. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2694818 · Cited by 813
Self-citationChen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces
Wang, Y., Chen, X., Gao, X., & Gao, S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627556 · Cited by 501
Self-citationVisual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationNorton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Nakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
“Among these methods, CCA is one of the most widely used methods in SSVEP-based BCIs due to its high efficiency, robustness, and simple implementation [10, 11, 15, 21 – 23].”
MethodResultA HIGH-SPEED BRAIN SPELLER USING STEADY-STATE VISUAL EVOKED POTENTIALS
NAKANISHI, M., WANG, Y., WANG, Y.-T., MITSUKURA, Y., & JUNG, T.-P. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500191 · Cited by 369
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
FREQUENCY RECOGNITION IN SSVEP-BASED BCI USING MULTISET CANONICAL CORRELATION ANALYSIS
ZHANG, Y., ZHOU, G., JIN, J., WANG, X., & CICHOCKI, A. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500130 · Cited by 357
A high-speed BCI based on code modulation VEP
Bin, G., Gao, X., Wang, Y., Li, Y., Hong, B., & Gao, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025015 · Cited by 305
Self-citationA high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Self-citationBrain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces
Chi, Y. M., Wang, Y.-T., Wang, Y., Maier, C., Jung, T.-P., & Cauwenberghs, G. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2174652 · Cited by 297
An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2076364 · Cited by 281
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
Waytowich, N., Lawhern, V. J., Garcia, J. O., Cummings, J., Faller, J., Sajda, P., & Vettel, J. M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae5d8 · Cited by 262
Neural Decoding of EEG Signals with Machine Learning: A Systematic Review
Saeidi, M., Karwowski, W., Farahani, F. V., Fiok, K., Taiar, R., Hancock, P. A., & Al-Juaid, A. (2021) · Brain Sciences · doi:10.3390/brainsci11111525 · Cited by 258
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Other feature types included correlation coefficients (Bin, Gao, Yan, Hong, & Gao, 2009; Horki, Neuper, Pfurtscheller, & Muller-Putz, 2010; Z. L. Lin, Zhang, Wu, & Gao, 2007; Y. T. Wang et al., 2011; Zhang et al., 2010), time domain parameters (Vidaurre, Kramer, Blankertz, & Schlogl, 2009), fractal…”
VEP-based brain-computer interfaces: time, frequency, and code modulations [Research Frontier
Bin, G., Gao, X., Wang, Y., Hong, B., & Gao, S. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.934562 · Cited by 256
Self-citationA Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
Multivariate synchronization index for frequency recognition of SSVEP-based brain–computer interface
Zhang, Y., Xu, P., Cheng, K., & Yao, D. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.018 · Cited by 233
SSVEP-based Bremen–BCI interface—boosting information transfer rates
Volosyak, I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036020 · Cited by 232
“In a six target SSVEP-based BCI, an average accuracy of 95.3% and ITR of 58 ± 9.6 bit min − 1 for 12 healthy participants were reported in [18].”
BackgroundInfluentialA novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
“We found that the multichannel data will not only yield a better and stable system performance, but will also be more convenient for the BCI application as the same electrode cap can be used for all users [27].”
BackgroundMethodLiu, B., Chen, X., Shi, N., Wang, Y., Gao, S., & Gao, X. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3114340 · Cited by 215
Self-citation(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
BETA: A Large Benchmark Database Toward SSVEP-BCI Application
Liu, B., Huang, X., Wang, Y., Chen, X., & Gao, X. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00627 · Cited by 209
“Among a variety of BCI paradigms, SSVEP based BCI (SSVEP-BCI) has gained widespread attention due to its non-invasiveness, high signal-to-noise ratio (SNR) and high information transfer rate (ITR) (Bin et al. (2009); Chen et al. (2015b)).”
Self-citationMa, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209
An Asynchronous P300 BCI With SSVEP-Based Control State Detection
Panicker, R. C., Puthusserypady, S., & Sun, Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116018 · Cited by 203
Lulé, D., Noirhomme, Q., Kleih, S. C., Chatelle, C., Halder, S., Demertzi, A., Bruno, M.-A., Gosseries, O., Vanhaudenhuyse, A., Schnakers, C., et al. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.030 · Cited by 189
“The visual P3 evoked potentials are presently the most robust BCI enabling accuracy close to 100% in healthy subjects (Bin et al., 2009; Blankertz et al., 2010; Sellers et al., 2006) and P3 paradigms also allow for high accuracy in patients with severe motor paralysis (e.”
Visual stimulus design for high-rate SSVEP BCI
Wang, Y., Wang, Y.-T., & Jung, T.-P. (2010) · Electronics Letters · doi:10.1049/el.2010.0923 · Cited by 183
Mahmood, M., Mzurikwao, D., Kim, Y.-S., Lee, Y., Mishra, S., Herbert, R., Duarte, A., Ang, C. S., & Yeo, W.-H. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0091-7 · Cited by 181
Spüler, M., Rosenstiel, W., & Bogdan, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051077 · Cited by 177
“When combining OCSVM with a different method of applying CCA by selecting the best individual channel [5] an accuracy of 95.00% was reached, which is the method we used online and also described in the methods section.”
MethodInfluentialHow Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176
“Steady-state visually evoked potentials based BCI systems use multiple visual stimuli (such as LEDs or boxes on a computer screen) that flicker at different frequencies (Friman et al., 2007; Martinez et al., 2007; Bin et al., 2009).”
BackgroundBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“Spelling or dialing applications [19] re-sults in higher ITR values, because there is no break between two commands caused by the processing time of the application.”
BackgroundInfluentialDecoding Individual Finger Movements from One Hand Using Human EEG Signals
Liao, K., Xiao, R., Gonzalez, J., & Ding, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085192 · Cited by 174
“Different patterns in brain signals discussed above due to activations of different functional brain regions have been identified and extracted as control features for BCI, such as event-related synchronization and de-synchronization (ERS/ ERD) originated from the motor cortex during real movement or motor imagery of…”
MethodA cell-phone-based brain–computer interface for communication in daily life
Wang, Y.-T., Wang, Y., & Jung, T.-P. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025018 · Cited by 173
“Future directions include: (1) the use of dry EEG electrodes over the scalp locations covered with hairs to avoid skin preparation and the use of conductive gels; and (2) the use of multi-channel EEG signals to enhance the accuracy and ITR of the BCI [18], as opposed to manually selecting a single channel from the rec…”
MethodSpelling with non-invasive Brain–Computer Interfaces – Current and future trends
Cecotti, H. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.08.003 · Cited by 172
Lin, S., Liu, J., Li, W., Wang, D., Huang, Y., Jia, C., Li, Z., Murtaza, M., Wang, H., Song, J., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02019 · Cited by 171
Self-citationA Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“The reason that we did not compose all of the cells of the matrix into six rectangular objects, as in [18], is that overly large white rectangular objects could be annoying to the subjects [29].”
BackgroundComparing user-dependent and user-independent training of CNN for SSVEP BCI
Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6a67 · Cited by 165
“The most widely used training-free method for SSVEP classification is the canonical correlation analysis (CCA) [7, 8].”
BackgroundMethodXu, M., Han, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
“CCA is a statistical way to measure the linear relationship between two multidimensional variables, which may have some underlying correlation [38], [39].”
BackgroundFeature learning from incomplete EEG with denoising autoencoder
Li, J., Struzik, Z., Zhang, L., & Cichocki, A. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.08.092 · Cited by 163
“In the case of a passive BCI, when using a steady-state visual evoked potential (SSVEP) BCI [6], the user may, for example, simply stare at an intended digital number shown on a screen to dial a phone number.”
MethodA user-friendly SSVEP-based brain–computer interface using a time-domain classifier
Luo, A., & Sullivan, T. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026010 · Cited by 161
“accuracy and ITR in a different way than [2].”
BackgroundResultTo train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
“CCA was then successfully implemented as a feature extraction algorithm alone with a fixed set of channels for all users in [14].”
BackgroundMethodInfluentialCombination of high-frequency SSVEP-based BCI and computer vision for controlling a robotic arm
Chen, X., Zhao, B., Wang, Y., & Gao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf594 · Cited by 159
Self-citationDecoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“On the other hand, in an online BCI system, such as the systems described in Lal et al. (2005), Bin et al. (2009), Hazrati and Erfanian (2010), Gui et al. (2015), Mondini et al. (2016), Wu (2016), and Khan and Hong (2017), the EEG data is processed in real-time giving real-time BCI outputs.”
MethodSpatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
Li, G., & Zhang, D. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150667 · Cited by 80
“Based on the previous study of SSVEP [13], principle frequency component and harmonic wave components of the signal were used for feature extraction with the way of projecting the signal to sine and cosine space (Inner Product, Eqs (1)-(6)).”
BackgroundMethodWaytowich, N. R., Lawhern, V. J., Bohannon, A. W., Ball, K. R., & Lance, B. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00430 · Cited by 79
“…(SSVEP) BCIs have been developed that correlate multichannel EEG with sinusoidal reference signals using Canonical Correlation Analysis (CCA) (Bin et al., 2009); however, the CCA method is mainly utilized for SSVEP BCIs due to the well-characterized steady-state frequency response and thus…”
Method
Metadata
- Authors
- Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2009-06-03
- Volume
- 6
- Issue
- 4
- Pages
- 046002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2105478324
- Cited by
- 773
- References
- 23
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.