An adaptive P300-based control system
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
An adaptive P300 brain-computer interface (BCI) using a 12 × 7 matrix explored new paradigms to improve bit rate and accuracy. During online use, the system adaptively selects the number of flashes to average. Five different flash patterns were tested. The 19-flash paradigm represents the typical row/column presentation (i.e. 12 columns and 7 rows). The 9- and 14-flash A and B paradigms present all items of the 12 × 7 matrix three times using either 9 or 14 flashes (instead of 19), decreasing the amount of time to present stimuli. Compared to 9-flash A, 9-flash B decreased the likelihood that neighboring items would flash when the target was not flashing, thereby reducing the interference from items adjacent to targets. 14-flash A also reduced the adjacent item interference and 14-flash B additionally eliminated successive (double) flashes of the same item. Results showed that the accuracy and bit rate of the adaptive system were higher than those of the non-adaptive system. In addition, 9- and 14-flash B produced significantly higher performance than their respective A conditions. The results also show the trend that the 14-flash B paradigm was better than the 19-flash pattern for naive users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundTemporary suppression of visual processing in an RSVP task: An attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037//0096-1523.18.3.849 · Cited by 2,260
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“…have been widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et…”
BackgroundSelf-citationTemporary suppression of visual processing in an RSVP task: an attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/0096-1523.18.3.849 · Cited by 1,649 · cited 1×
“Reducing the interference from neighboring flashing characters can decrease this ‘attentional blink’ (Raymond et al 1992, Vogel and Luck 2002, Fazel-Rezai 2007, Kranczioch et al 2007).”
BackgroundA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 3×
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
MethodBrain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754 · cited 1×
“P300-based BCIs work without training, and may work in subjects who are not successful with other approaches (Sellers and Donchin 2006, Birbaumer and Cohen 2007, Allison and Neuper 2010).”
BackgroundToward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 2×
“The most common approach is to apply improved signal processing and machine learning algorithms (Jung et al 2001, Xu et al 2004, Hill et al 2008, Lenhardt et al 2008, Krusienski et al 2008, Guger et al 2009).”
BackgroundMethodA P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711 · cited 3×
“P300-based BCIs work without training, and may work in subjects who are not successful with other approaches (Sellers and Donchin 2006, Birbaumer and Cohen 2007, Allison and Neuper 2010).”
BackgroundSelf-citationRepetition blindness: Type recognition without token individuation
Kanwisher, N. G. (1987) · Cognition · doi:10.1016/0010-0277(87)90016-3 · Cited by 664 · cited 1×
“Furthermore, the user might not see the second flash because of ‘repetition blindness’ (Kanwisher 1987).”
BackgroundAnalysis and visualization of single‐trial event‐related potentials
Jung, T., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2001) · Human Brain Mapping · doi:10.1002/hbm.1050 · Cited by 655 · cited 1×
“The most common approach is to apply improved signal processing and machine learning algorithms (Jung et al 2001, Xu et al 2004, Hill et al 2008, Lenhardt et al 2008, Krusienski et al 2008, Guger et al 2009).”
MethodHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 2×
“The most common approach is to apply improved signal processing and machine learning algorithms (Jung et al 2001, Xu et al 2004, Hill et al 2008, Lenhardt et al 2008, Krusienski et al 2008, Guger et al 2009).”
BackgroundMethodSelf-citationA BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637 · cited 1×
“Untrained subjects have used BCIs based on SSVEPs in speller systems (Gao et al 2003, Friman et al 2007, Sugiarto et al 2009).”
MethodControl of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589 · cited 1×
“Unfortunately, SSVEP BCIs do not work for some subjects (Lalor et al 2005, M¨uller-Putz et al 2005, Allison et al 2008, M¨uller-Putz and Pfurtscheller 2008), and some users may find the flickering lights annoying (Allison et al 2010).”
BackgroundP300 and Tracking Difficulty: Evidence For Multiple Resources in Dual‐Task Performance
Isreal, J. B., Chesney, G. L., Wickens, C. D., & Donchin, E. (1980) · Psychophysiology · doi:10.1111/j.1469-8986.1980.tb00146.x · Cited by 579 · cited 1×
“Isreal et al (1980) showed that P300s are diminished if subjects divide attention between visual stimuli in different regions.”
BackgroundTownsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 11×
“Townsend et al (2010) have taken a different approach.”
BackgroundMethodInfluentialSelf-citationPfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548 · cited 1×
“…widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et al 2008).”
BackgroundPatients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Müller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534 · cited 1×
“Unfortunately, SSVEP BCIs do not work for some subjects (Lalor et al 2005, M¨uller-Putz et al 2005, Allison et al 2008, M¨uller-Putz and Pfurtscheller 2008), and some users may find the flickering lights annoying (Allison et al 2010).”
BackgroundSellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501 · cited 10×
“Future work should assess different flash patterns at different TTIs, evaluate possible benefits of training or alternate displays, and consider differences between subjects (younger subjects, and / or some types of gamers, may have less trouble with faster flashes).”
BackgroundMethodResultInfluentialSelf-citationSteady-State VEP-Based Brain-Computer Interface Control in an Immersive 3D Gaming Environment
Lalor, E. C., Kelly, S. P., Finucane, C., Burke, R., Smith, R., Reilly, R. B., & McDarby, G. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3156 · Cited by 421
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403 · cited 2×
“…collected from the first few trials could allow adequately accurate communication) since presenting flashes after effective classification increases the time for each character selection and decreases the bit rate (Serby et al 2005, Allison and Pineda 2006, Lenhardt et al 2008, Townsend et al 2010).”
BackgroundMethodA brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400 · cited 1×
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
MethodSelf-citationDistortion of ERP averages due to overlap from temporally adjacent ERPs: Analysis and correction
WOLDORFF, M. G. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb03209.x · Cited by 384
Allison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350 · cited 16×
“There are several ways to improve the classification accuracy and bit rate (also known as the ITR) in a P300 BCI (Allison and Neuper 2010).”
BackgroundInfluentialSelf-citationBCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344 · cited 1×
“Unfortunately, SSVEP BCIs do not work for some subjects (Lalor et al 2005, M¨uller-Putz et al 2005, Allison et al 2008, M¨uller-Putz and Pfurtscheller 2008), and some users may find the flickering lights annoying (Allison et al 2010).”
BackgroundSelf-citationAn Asynchronously Controlled EEG-Based Virtual Keyboard: Improvement of the Spelling Rate
Scherer, R., Muller, G. R., Neuper, C., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827062 · Cited by 340 · cited 1×
“…widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et al 2008).”
BackgroundSelf-citationThe Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338 · cited 1×
“…widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et al 2008).”
BackgroundThe wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationTowards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327 · cited 1×
“Unfortunately, SSVEP BCIs do not work for some subjects (Lalor et al 2005, M¨uller-Putz et al 2005, Allison et al 2008, M¨uller-Putz and Pfurtscheller 2008), and some users may find the flickering lights annoying (Allison et al 2010).”
BackgroundSelf-citationAn auditory oddball (P300) spelling system for brain‐computer interfaces
Furdea, A., Halder, S., Krusienski, D. J., Bross, D., Nijboer, F., Birbaumer, N., & Kübler, A. (2009) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00783.x · Cited by 326 · cited 1×
“…BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al 2010).”
BackgroundPiccione, F., Giorgi, F., Tonin, P., Priftis, K., Giove, S., Silvoni, S., Palmas, G., & Beverina, F. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.024 · Cited by 325 · cited 1×
“The EEG was downsampled from 200 to 40 Hz by selecting every fifth sample from the filtered EEG. Single sub-trials lasting 500 ms were extracted from the data since Piccione et al (2006) reported that P300 latency for healthy people is 445 ms and ten healthy subjects participated in this study.”
MethodNeuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317 · cited 1×
“…widely used and validated with able-bodied and disabled subjects, who often attain satisfactory results even without extensive training (Pfurtscheller and Neuper 2001, Neuper et al 2003, Pfurtscheller et al 2003, Scherer et al 2004, K ¨ubler et al 2005, Vaughan et al 2006, Blankertz et al 2008).”
BackgroundSelf-citationKübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303 · cited 2×
“Using a calibration data set from each participant, they determined the optimal number of trials per average for each participant using a metric referred to as the written symbol rate (WSR) (K¨ubler et al 2009).”
BackgroundMethodP300 amplitude is determined by target‐to‐target interval
Gonsalvez, C. J., & Polich, J. (2002) · Psychophysiology · doi:10.1017/s0048577201393137 · Cited by 279 · cited 2×
“Since the inter-stimulus interval did not change in this study, changing the probability has a proportionate effect on the TTI (Gonsalvez and Polich 2002).”
BackgroundXu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258 · cited 1×
“The most common approach is to apply improved signal processing and machine learning algorithms (Jung et al 2001, Xu et al 2004, Hill et al 2008, Lenhardt et al 2008, Krusienski et al 2008, Guger et al 2009).”
MethodDelayed working memory consolidation during the attentional blink
Vogel, E. K., & Luck, S. J. (2002) · Psychonomic Bulletin & Review · doi:10.3758/bf03196329 · Cited by 247 · cited 1×
“Reducing the interference from neighboring flashing characters can decrease this ‘attentional blink’ (Raymond et al 1992, Vogel and Luck 2002, Fazel-Rezai 2007, Kranczioch et al 2007).”
BackgroundERPs evoked by different matrix sizes: implications for a brain computer interface (BCI) system
Allison, B. Z., & Pineda, J. A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814448 · Cited by 225 · cited 4×
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
BackgroundMethodResultInfluentialSelf-citationAn Adaptive P300-Based Online Brain–Computer Interface
Lenhardt, A., Kaper, M., & Ritter, H. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.912816 · Cited by 190 · cited 5×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundMethodInfluentialTemporal dynamics of access to consciousness in the attentional blink
Kranczioch, C., Debener, S., Maye, A., & Engel, A. K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.044 · Cited by 143 · cited 1×
“Reducing the interference from neighboring flashing characters can decrease this ‘attentional blink’ (Raymond et al 1992, Vogel and Luck 2002, Fazel-Rezai 2007, Kranczioch et al 2007).”
BackgroundTime–frequency analysis reveals multiple functional components during oddball P300
Kolev, V., Demiralp, T., Yordanova, J., Ademoglu, A., & Isoglu-Alkaç, Ü. (1997) · NeuroReport · doi:10.1097/00001756-199705260-00050 · Cited by 141 · cited 1×
“Although the P300 is primarily in the band 0.1–4 Hz (Jansen et al 2004), it can also be found in higher bands (Kolev et al 1997).”
BackgroundInfluentialAllison, B. Z., & Pineda, J. A. (2005) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2005.02.007 · Cited by 135 · cited 6×
“Allison and Pineda (2006) introduced the ‘multiple flash’ approach, in which flashes were designed around binary decomposition of the available choices.”
BackgroundResultInfluentialSelf-citationHabituation of P300 from visual stimuli
Ravden, D., & Polich, J. M. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(98)00039-7 · Cited by 121 · cited 1×
“This may cause P300 habituation, which refers to the fact that the P300 may become smaller if the same stimulus is presented repeatedly (Ravden and Polich 1998, Jin et al 2010b).”
BackgroundMartens, S. M. M., Hill, N. J., Farquhar, J., & Schölkopf, B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026003 · Cited by 114 · cited 2×
“In addition, even if a P300 response is produced, overlapping target epochs would ensue, resulting in waveform distortion (Woldorff 1993, Martens et al 2009).”
BackgroundJin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0689-8 · Cited by 111 · cited 6×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundMethodResultInfluentialSelf-citationThe Time Constant in P300 Recording
Duncan‐Johnson, C. C., & Donchin, E. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01440.x · Cited by 103 · cited 3×
“This issue is important since increasing the probability that a target character flashes (that is, reducing the TTI) decreases the P300 amplitude (Sellers et al 2006, Duncan-Johnson and Donchin 1979).”
BackgroundHuman Error in P300 Speller Paradigm for Brain-Computer Interface
Fazel-Rezai, R. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352840 · Cited by 101 · cited 2×
“Reducing the interference from neighboring flashing characters can decrease this ‘attentional blink’ (Raymond et al 1992, Vogel and Luck 2002, Fazel-Rezai 2007, Kranczioch et al 2007).”
BackgroundA Boosting Approach to P300 Detection with Application to Brain-Computer Interfaces
Hoffmann, U., Garcia, G., Vesin, J.-M., Diserens, K., & Ebrahimi, T. (2005) · Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005. · doi:10.1109/cne.2005.1419562 · Cited by 89 · cited 1×
“P300 BCIs have been validated with disabled users, with visual, auditory and tactile stimuli (Allison and Pineda 2003, Hoffmann et al 2005, 2008, Sellers et al 2006, 2010, Allison and Pineda 2006, Sellers and Donchin 2006, Furdea et al 2009, K¨ubler et al 2009, Guger et al 2009, Townsend et al…”
MethodLakey, C. E., Berry, D. R., & Sellers, E. W. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025019 · Cited by 88 · cited 1×
“A third and related possibility is that SAINSTs prevent subjects from ‘zoning in’ on the target—that is, entering a state of highly focused attention that may lead to a larger P300 amplitude (Lakey et al 2011).”
BackgroundSelf-citationAn Empirical Bayesian Framework for Brain–Computer Interfaces
Lei, X., Yang, P., & Yao, D. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2027705 · Cited by 81 · cited 1×
“Lei et al (2009) reported that BLDA classified more accurately than linear discriminant analysis (LDA) and support vector machine (SVM) when they were applied to motor imagery classification.”
BackgroundAn Exploratory Study of Factors Affecting Single Trial P300 Detection
Jansen, B., Allam, A., Kota, P., Lachance, K., Osho, A., & Sundaresan, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826684 · Cited by 71 · cited 1×
“Although the P300 is primarily in the band 0.1–4 Hz (Jansen et al 2004), it can also be found in higher bands (Kolev et al 1997).”
BackgroundInfluentialSpelling with Steady-State Visual Evoked Potentials
Friman, O., Luth, T., Volosyak, I., & Graser, A. (2007) · 2007 3rd International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369683 · Cited by 68
A new P300 stimulus presentation pattern for EEG-based spelling systems
Jin, J., Horki, P., Brunner, C., Wang, X., Neuper, C., & Pfurtscheller, G. (2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.029 · Cited by 67 · cited 6×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundMethodResultInfluentialSelf-citationP300 Chinese input system based on Bayesian LDA
Jin, J., Allison, B. Z., Brunner, C., Wang, B., Wang, X., Zhang, J., Neuper, C., & Pfurtscheller, G. (2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.003 · Cited by 66 · cited 6×
“Indeed, this precedent was established in the first P300 BCI paper (Farwell and Donchin 1988) and has since become commonplace (Lenhardt et al 2008, Krusienski et al 2008, Jin et al 2010a).”
BackgroundMethodResultInfluentialSelf-citationEffects of Stimulus Type and of Error-Correcting Code Design on BCI Speller Performance
Hill, J., Farquhar, J. D. R., Martens, S., Bießmann, F., & Schölkopf, B. (2008) · Cited by 52
Comparison of event-related potentials in attentional blink and repetition blindness
Koivisto, M., & Revonsuo, A. (2007) · Brain Research · doi:10.1016/j.brainres.2007.10.082 · Cited by 50 · cited 1×
“(3) Preventing items from flashing twice in succession, as the second flash might generate a small P300 or might not even be fully processed due to ‘repetition blindness’ (Schendan 1997, Fazel-Rezai 2007, Koivisto and Revonsuo 2008, Salvaris and Sepulveda 2009).”
BackgroundOptimization Strategy for SSVEP-Based BCI in Spelling Program Application
Sugiarto, I., Allison, B. Z., & Gräser, A. (2009) · International Conference on Computer Engineering and Technology · doi:10.1109/iccet.2009.189 · Cited by 34 · cited 1×
“Untrained subjects have used BCIs based on SSVEPs in speller systems (Gao et al 2003, Friman et al 2007, Sugiarto et al 2009).”
MethodSelf-citationEarly brain potentials link repetition blindness, priming and novelty detection
Schendan, H. E., Kanwisher, N., & Kutas, M. (1997) · Neuroreport · doi:10.1097/00001756-199705260-00030 · Cited by 28
Perceptual errors in the Farwell and Donchin matrix speller
Salvaris, M., & Sepulveda, F. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109286 · Cited by 15
Exploiting P300 amplitude variations can improve classification accuracy in Donchin's BCI speller
Citi, L., Poli, R., & Cinel, C. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109337 · Cited by 10 · cited 1×
“This idea was suggested by Woldorff (1993), and Citi et al (2009) capitalized on the TTI variability to develop a model to improve the classification accuracy by accounting for sequence effects.”
Method
Cited by
Deep learning based on Batch Normalization for P300 signal detection
Liu, M., Wu, W., Gu, Z., Yu, Z., Qi, F., & Li, Y. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.08.039 · Cited by 230
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
A Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“To fulfill this goal, several P300-based optimal approaches have been developed, focused mainly on the stimulus presentation paradigm design by decreasing the number of flashes per trial [11]–[15].”
MethodXu, M., Han, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975614 · Cited by 165
“Jin et al. designed an adaptive method for P300 speller to encode 84 instructions [26].”
Method
Metadata
- Authors
- Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-04-08
- Volume
- 8
- Issue
- 3
- Pages
- 036006
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2089594124
- Cited by
- 158
- References
- 60
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.