Enhancing the classification accuracy of steady-state visual evoked potential-based brain–computer interfaces using phase constrained canonical correlation analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this study, a novel method of phase constrained canonical correlation analysis (p-CCA) is presented for classifying steady-state visual evoked potentials (SSVEPs) using multichannel electroencephalography (EEG) signals. p-CCA is employed to improve the performance of the SSVEP-based brain-computer interface (BCI) system using standard CCA. SSVEP response phases are estimated based on the physiologically meaningful apparent latency and are added as a reliable constraint into standard CCA. The results of EEG experiments involving 10 subjects demonstrate that p-CCA consistently outperforms standard CCA in classification accuracy. The improvement is up to 6.8% using 1-4 s data segments. The results indicate that the reliable measurement of phase information is of importance in SSVEP-based BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
Self-citation
Cited by
Chen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationVisual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationNakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
“More details for each method can be found in the corresponding references [5, 15, 29 – 33].”
MethodA HIGH-SPEED BRAIN SPELLER USING STEADY-STATE VISUAL EVOKED POTENTIALS
NAKANISHI, M., WANG, Y., WANG, Y.-T., MITSUKURA, Y., & JUNG, T.-P. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500191 · Cited by 369
FREQUENCY RECOGNITION IN SSVEP-BASED BCI USING MULTISET CANONICAL CORRELATION ANALYSIS
ZHANG, Y., ZHOU, G., JIN, J., WANG, X., & CICHOCKI, A. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500130 · Cited by 357
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
A Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
Liu, B., Chen, X., Shi, N., Wang, Y., Gao, S., & Gao, X. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3114340 · Cited by 215
Self-citation(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Comparing user-dependent and user-independent training of CNN for SSVEP BCI
Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6a67 · Cited by 165
“Many studies have used a frequency-phase coding approach in the stimulus design [12, 27] and use the phase information as part of the classifier to detect the SSVEP targets [28, 29].”
MethodTo train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
“The difference in SSVEP phase responses across subjects, due to individual variation of visual latencies [26], is relatively small compared with the periods of the stimuli [19].”
BackgroundResultInfluentialRecursive Bayesian Coding for BCIs
Higger, M., Quivira, F., Akcakaya, M., Moghadamfalahi, M., Nezamfar, H., Cetin, M., & Erdogmus, D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2590959 · Cited by 19
Metadata
- Authors
- Pan, J., Gao, X., Duan, F., Yan, Z., & Gao, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-05-13
- Volume
- 8
- Issue
- 3
- Pages
- 036027
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1998344981
- Cited by
- 139
- References
- 2
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.