Control and modelling of continuum robots are challenging tasks for robotic researchers. Most works on modelling are limited to piecewise constant curvature. In many cases they neglect to model the actuators or avoid a continuum approach. In particular, in the latter case this leads to a complex model hardly implemented. In this work, a geometrically exact steady-state model of a tendon-driven manipulator inspired by the octopus arm is presented. It takes a continuum approach, fast enough to be implemented in the control law, and includes a model of the actuation system. The model was experimentally validated and the results are reported. In conclusion, the model presented can be used as a tool for mechanical design of continuum tendon-driven manipulators, for planning control strategies or as internal model in an embedded system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297 · cited 1×
“They pertain to the class of hyper-redundant manipulators, which consists of a large number of short rigid links, but go beyond them by virtue of their infinite degrees of freedom [3].”
BackgroundSoft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708 · cited 1×
“The effort to enhance the performance of robot manipulators has resulted in an increased attention towards continuum soft manipulators and in particular towards ‘biologically inspired’ soft manipulators [1, 2].”
BackgroundNonlinear Problems of Elasticity
(2005) · Applied Mathematical Sciences · doi:10.1007/0-387-27649-1 · Cited by 1,670
Lectures on Classical Differential Geometry.
Springer, C. E., & Struik, D. J. (1952) · The American Mathematical Monthly · doi:10.2307/2307130 · Cited by 1,370
A finite strain beam formulation. The three-dimensional dynamic problem. Part I
Simo, J. C. (1985) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(85)90050-7 · Cited by 1,348
Hannan, M. W., & Walker, I. D. (2003) · Journal of Robotic Systems · doi:10.1002/rob.10070 · Cited by 737 · cited 1×
“Continuum soft robots have been inspired by biological systems, for example elephant trunks [4, 5], cephalopod arms [2] and mammalian tongues, which are commonly known as muscular hydrostats (for more details on the octopus arm muscular hydrostat structure see [6]).”
BackgroundMechanics Modeling of Tendon-Driven Continuum Manipulators
Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2002311 · Cited by 655 · cited 2×
“For a detailed mechanical analysis of this tendon load see the fundamental work of Camarillo et al [8].”
MethodGeometrically Exact Models for Soft Robotic Manipulators
Trivedi, D., Lotfi, A., & Rahn, C. D. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.924923 · Cited by 428 · cited 1×
“Exact solutions also exist [13] but, in any case, the bottle neck in their use is the real time implementation of the model due to the computational effort required.”
BackgroundDesign of a biomimetic robotic octopus arm
Laschi, C., Mazzolai, B., Mattoli, V, Cianchetti, M., & Dario, P. (2009) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/4/1/015006 · Cited by 253
Self-citationElephant trunk type elastic manipulator - a tool for bulk and liquid materials transportation
Cieślak, R., & Morecki, A. (1999) · Robotica · doi:10.1017/s0263574799001009 · Cited by 186
The Arrangement and Function of octopus Arm Musculature and Connective Tissue
Kier, W. M., & Stella, M. P. (2007) · Journal of Morphology · doi:10.1002/jmor.10548 · Cited by 184 · cited 1×
“Continuum soft robots have been inspired by biological systems, for example elephant trunks [4, 5], cephalopod arms [2] and mammalian tongues, which are commonly known as muscular hydrostats (for more details on the octopus arm muscular hydrostat structure see [6]).”
BackgroundDesign concept and validation of a robotic arm inspired by the octopus
Cianchetti, M., Arienti, A., Follador, M., Mazzolai, B., Dario, P., & Laschi, C. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2010.12.004 · Cited by 174
Self-citationOctopuses Use a Human-like Strategy to Control Precise Point-to-Point Arm Movements
Sumbre, G., Fiorito, G., Flash, T., & Hochner, B. (2006) · Current Biology · doi:10.1016/j.cub.2006.02.069 · Cited by 171 · cited 3×
“Octopus fetching movement composed of three bends: proximal, medial and distal (reproduced with the permission of the author and publisher of [21]).”
BackgroundInfluentialThree dimensional statics for continuum robotics
Jones, B. A., Gray, R. L., & Turlapati, K. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354199 · Cited by 154 · cited 1×
“Recently Jones and Gray [10] presented a steady-state model of a continuous robot but they did not model the actuation acting on it.”
BackgroundStudy and fabrication of bioinspired Octopus arm mockups tested on a multipurpose platform
Calisti, M., Arienti, A., Elena Giannaccini, M., Follador, M., Giorelli, M., Cianchetti, M., Mazzolai, B., Laschi, C., & Dario, P. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5625959 · Cited by 48 · cited 1×
“There are four cables for each anchorage cross section aligned with the axes n and b as shown in figure 4 (for more detail on the design of such a prototype see [19, 20]).”
BackgroundSelf-citationA 3D dynamic model for continuum robots inspired by an octopus arm
Zheng, T., Branson, D. T., Guglielmino, E., & Caldwell, D. G. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979599 · Cited by 36 · cited 1×
“Zheng and Branson [12] developed a model based on a spring-mass approach instead of a continuum one that is too complex to be implemented in an embedded system.”
Background
Cited by
Soft robotics: a bioinspired evolution in robotics
Kim, S., Laschi, C., & Trimmer, B. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.03.002 · Cited by 2,092
Self-citationSoft robotics: Technologies and systems pushing the boundaries of robot abilities
Laschi, C., Mazzolai, B., & Cianchetti, M. (2016) · Science Robotics · doi:10.1126/scirobotics.aah3690 · Cited by 1,570
Self-citationContinuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
A novel type of compliant and underactuated robotic hand for dexterous grasping
Deimel, R., & Brock, O. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915592961 · Cited by 1,084
“However, they can easily be cut or pierced.”
BackgroundToward Perceptive Soft Robots: Progress and Challenges
Wang, H., Totaro, M., & Beccai, L. (2018) · Advanced Science · doi:10.1002/advs.201800541 · Cited by 753
Metadata
- Authors
- Renda, F., Cianchetti, M., Giorelli, M., Arienti, A., & Laschi, C.
- Venue
- Bioinspiration & Biomimetics
- Publisher
- IOP Publishing
- Published
- 2012-05-22
- Volume
- 7
- Issue
- 2
- Pages
- 025006
- ISSN
- 1748-3182 (ISSN-L)
- 1748-3190
- OpenAlex
- W2158730742
- Cited by
- 225
- References
- 16
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.