The DOI matches its Crossref record.
Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems
Open accessAbstract
Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL(-1) GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poly (lactic acid)-based biomaterials for orthopaedic regenerative engineering
Narayanan, G., Vernekar, V. N., Kuyinu, E. L., & Laurencin, C. T. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.015 · Cited by 484
Self-citationTendon and ligament regeneration and repair: Clinical relevance and developmental paradigm
Yang, G., Rothrauff, B. B., & Tuan, R. S. (2013) · Birth Defects Research Part C: Embryo Today: Reviews · doi:10.1002/bdrc.21041 · Cited by 469
Primed Mesenchymal Stem Cells Alter and Improve Rat Medial Collateral Ligament Healing
Saether, E. E., Chamberlain, C. S., Aktas, E., Leiferman, E. M., Brickson, S. L., & Vanderby, R. (2016) · Stem Cell Reviews and Reports · doi:10.1007/s12015-015-9633-5 · Cited by 34
Metadata
- Authors
- James, R., Kumbar, S. G., Laurencin, C. T., Balian, G., & Chhabra, A. B.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 6
- Issue
- 2
- Pages
- 025011
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W1987245189
- Cited by
- 164
- References
- 0
- FWCI
- 16.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems. https://app.cochat.ai/papers/10.1088/1748-6041/6/2/025011
- The paper
- James, R., Kumbar, S. G., Laurencin, C. T., Balian, G., & Chhabra, A. B. (2011). Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems. Biomedical Materials. https://doi.org/10.1088/1748-6041/6/2/025011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.