CoChat

Hemocompatibility improvement of decellularized spleen matrix for constructing transplantable bioartificial liver

Open access
Liu, Peng, Tian, Boyan, Yang, Lifei, Zheng, Xinglong, Zhang, Xufeng, Li, Jianhui, Liu, Xuemin, Lv, Yi, Xiang, Junxi · 2019 · Biomedical Materials
Cited by 14

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Thrombogenicity is the predominant obstacle to successful implantation of decellularized spleen matrix (DSM). The aim of this study was to construct a transplantable functional bioartificial liver (BAL) with the use of DSM. This was achieved by layer-by-layer electrostatic immobilization technique by using poly dimethyl diallyl ammonium chloride and heparin. After heparin immobilization, DSM gradually turned from translucent into completely opaque milky white. Toluidine blue staining showed strong positive staining of the entire coated DSM. In vitro diluted blood perfusion test showed that the splenic arterial pressure of the heparin-coated DSM was much lower than that of the non-coated DSM (p < 0.01). Then, we heterotopically transplanted the modified DSM into rat hepatic injury model for 6 h to evaluate the hemocompatibility in vivo. Overall, HE staining and vWF immunohistochemistry all confirmed that heparin-coated DSM has a satisfactory anticoagulant effect. Based on the heparin-coated DSM, BALs were built with the use of rat primary hepatocytes. Our results demonstrate that these heparin-coated BALs satisfied anticoagulant effects even after 6 h. Immunofluorescence of ALB and G6PC also showed that hepatocytes in heparin-coated BAL have significantly higher cell viability and function than the non-coated group. However, serum analysis did not indicate a significant difference between the two groups but a slight trend of improvement with respect to serum albumin (p = 0.156) and aspartate transaminase (p = 0.140). In conclusion, we demonstrated that the BAL constructed by heparin-coated DSM can exert satisfactory short-term anticoagulant effects and can compensate for a certain degree of liver function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1748-605x/aaf375

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 14

Metadata

Authors
Liu, P., Tian, B., Yang, L., Zheng, X., Zhang, X., Li, J., Liu, X., Lv, Y., & Xiang, J.
Venue
Biomedical Materials
Published
2019-01-04
Volume
14
Issue
2
Pages
025003
ISSN
  • 1748-6041 (ISSN-L)
  • 1748-605X
OpenAlex
W2901806411
Cited by
14
References
7
FWCI
1.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemocompatibility improvement of decellularized spleen matrix for constructing transplantable bioartificial liver. https://app.cochat.ai/papers/10.1088/1748-605x/aaf375
The paper
Liu, P., Tian, B., Yang, L., Zheng, X., Zhang, X., Li, J., Liu, X., Lv, Y., & Xiang, J. (2019). Hemocompatibility improvement of decellularized spleen matrix for constructing transplantable bioartificial liver. Biomedical Materials. https://doi.org/10.1088/1748-605x/aaf375

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.