The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Open accessAbstract
Analyses have been performed, using on-line selected ion flow tube mass spectrometry (SIFT-MS), of the breath of three healthy volunteers, as exhaled via the mouth and the nose and also of the air in the oral cavity during breath hold, each morning over a period of one month. Nine trace compounds have been quantified and concentration distributions have been constructed. Of these compounds, the levels of acetone, methanol and isoprene are the same in the mouth-exhaled and the nose-exhaled breath; hence, we deduce that these compounds are totally systemic. The levels of ammonia, ethanol and hydrogen cyanide are much lower in the nose-exhaled breath than in the mouth-exhaled breath and highest in the oral cavity, indicating that these compounds are largely generated in the mouth with little being released at the alveolar interface. Using the same ideas, both the low levels of propanol and acetaldehyde in mouth-exhaled breath appear to have both oral and systemic components. Formaldehyde is at levels in mouth- and nose-exhaled breath and the oral cavity that are lower than that of the ambient air and so its origin is difficult to ascertain, but it appears to be partially systemic. These results indicate that serious contamination of alveolar breath exhaled via the mouth can occur and if breath analysis is to be used to diagnose metabolic disease then analyses should be carried out of both mouth- and nose-exhaled breath to identify the major sources of particular trace compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citationTurner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citation
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Self-citationClinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Metadata
- Authors
- Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2008-09-01
- Volume
- 2
- Issue
- 3
- Pages
- 037013
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2034754469
- Cited by
- 164
- References
- 3
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity. https://app.cochat.ai/papers/10.1088/1752-7155/2/3/037013
- The paper
- Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008). Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity. Journal of Breath Research. https://doi.org/10.1088/1752-7155/2/3/037013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.