Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Analyses have been performed, using on-line selected ion flow tube mass spectrometry (SIFT-MS), of the breath of three healthy volunteers, as exhaled via the mouth and the nose and also of the air in the oral cavity during breath hold, each morning over a period of one month. Nine trace compounds have been quantified and concentration distributions have been constructed. Of these compounds, the levels of acetone, methanol and isoprene are the same in the mouth-exhaled and the nose-exhaled breath; hence, we deduce that these compounds are totally systemic. The levels of ammonia, ethanol and hydrogen cyanide are much lower in the nose-exhaled breath than in the mouth-exhaled breath and highest in the oral cavity, indicating that these compounds are largely generated in the mouth with little being released at the alveolar interface. Using the same ideas, both the low levels of propanol and acetaldehyde in mouth-exhaled breath appear to have both oral and systemic components. Formaldehyde is at levels in mouth- and nose-exhaled breath and the oral cavity that are lower than that of the ambient air and so its origin is difficult to ascertain, but it appears to be partially systemic. These results indicate that serious contamination of alveolar breath exhaled via the mouth can occur and if breath analysis is to be used to diagnose metabolic disease then analyses should be carried out of both mouth- and nose-exhaled breath to identify the major sources of particular trace compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Increased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232 · cited 2×
“generated in the airways [3, 4] and the oral cavity [5, 6] and that”
BackgroundDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801 · cited 5×
“Quantification of the trace gases is achieved utilizing the on-board computer and kinetics database [8, 9].”
BackgroundMethodInfluentialSelf-citationQuantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406 · cited 4×
“The first two compounds have received considerable attention over the years, breath ammonia because of its association with renal disease [15] and ethanol because of its social relevance.”
BackgroundMethodInfluentialSelf-citationTurner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citationCope, K., Risby, T., & Diehl, A. M. (2000) · Gastroenterology · doi:10.1053/gast.2000.19267 · Cited by 357 · cited 1×
“It has been demonstrated by previous SIFTMS studies that ethanol is at least partially generated in the oral cavity, especially when sugars are present in the mouth [11] and it has also been postulated that ethanol is generated by gut bacteria [29].”
MethodLung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264 · cited 1×
“Methanol in the breath is thought to be the result of the ingestion of fruit or aspartame [18, 19] and isoprene is known to be produced in cholesterol biosynthesis [20].”
BackgroundOral malodor‐related parameters in the Chinese general population
Liu, X. N., Shinada, K., Chen, X. C., Zhang, B. X., Yaegaki, K., & Kawaguchi, Y. (2006) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2005.00862.x · Cited by 255
Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring
(2005) · doi:10.1142/5796 · Cited by 247
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Self-citationOn the mammalian acetone metabolism: from chemistry to clinical implications
Kalapos, M. P. (2003) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(03)00051-5 · Cited by 224
Španěl, P., Smith, D., Holland, T. A., Singary, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j · Cited by 189 · cited 1×
“This had been implied much earlier by the discovery that formaldehyde appears in the headspace above urine donated by patients suffering from bladder and prostate cancer [33].”
BackgroundSelf-citationThe Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960731)10:10<1183::aid-rcm641>3.0.co;2-3 · Cited by 177
Self-citationBREATH-ACETONE AND BLOOD-SUGAR MEASUREMENTS IN DIABETES
Tassopoulos, C. N., Barnett, D., & Russell Fraser, T. (1969) · The Lancet · doi:10.1016/s0140-6736(69)92222-3 · Cited by 169
A review of the current literature on management of halitosis
Van Den Broek, A., Feenstra, L., & De Baat, C. (2008) · Oral Diseases · doi:10.1111/j.1601-0825.2006.01350.x · Cited by 164
Carroll, W. D., Lenney, W., Wang, T., Španěl, P., Alcock, A., & Smith, D. C. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20170 · Cited by 163 · cited 5×
“In our first studies [14, 25], we did not have sufficient evidence to shown that the HCN was predominantly produced in the mouth cavity of healthy individuals, but this is clearly demonstrated in the present study.”
BackgroundInfluentialSelf-citationEndogenous Production of Methanol after the Consumption of Fruit
Lindinger, W., Taucher, J. A., Jordan, A., Hansel, A., & Vogel, W. (1997) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.1997.tb03862.x · Cited by 157
The challenge of breath analysis for clinical diagnosis and therapeutic monitoring
Smith, D. C., & Španěl, P. (2007) · The Analyst · doi:10.1039/b700542n · Cited by 145
Self-citationTurner, C., Španěl, P., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/002 · Cited by 140
Self-citationModeling Soluble Gas Exchange in the Airways and Alveoli
Anderson, J. C., BABB, A. L., & Hlastala, M. P. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1630600 · Cited by 136
Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions
Smith, D. C., Turner, C., & Španěl, P. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/014004 · Cited by 127 · cited 3×
“In this way, the level distributions of the common volatile trace compounds present in mouthexhaled breath have been defined for significant cohorts of health volunteers [10].”
BackgroundMethodResultSelf-citationAcetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4–83 years
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/011001 · Cited by 116 · cited 2×
“HCN is a recent SIFT-MS discovery in the mouth-exhaled breath of healthy individuals [14, 25].”
BackgroundResultSelf-citationSmith, D. C., Wang, T., Pysanenko, A., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3434 · Cited by 105 · cited 1×
“Given the great interest that there has been in breath ammonia, which is ongoing, it is vital to ascertain the origin of mouth-exhaled breath ammonia and our most recent results for this have been recently reported in detail [28].”
ResultSelf-citationThe concentration distributions of some metabolites in the exhaled breath of young adults
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/2/026001 · Cited by 78 · cited 3×
“HCN is a recent SIFT-MS discovery in the mouth-exhaled breath of healthy individuals [14, 25].”
BackgroundMethodResultSelf-citationSelected Ion Flow Tube Mass Spectrometry for On-Line Trace Gas Analysis in Biology and Medicine
Španěl, P., & Smith, D. C. (2007) · European Journal of Mass Spectrometry · doi:10.1255/ejms.843 · Cited by 74 · cited 1×
“The SIFT-MS technique alluded to above has been described in detail in several papers [9, 12] and need not be repeated here.”
MethodSelf-citationDetection of isopropyl alcohol in a patient with diabetic ketoacidosis
Jones, A. E., & Summers, R. L. (2000) · Journal of Emergency Medicine · doi:10.1016/s0736-4679(00)00203-1 · Cited by 61
Bad breath and periodontal disease: how related are they?
Rosenberg, M. (2005) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2005.00874.x · Cited by 55 · cited 1×
“generated in the airways [3, 4] and the oral cavity [5, 6] and that”
BackgroundŠpaněl, P., Turner, C., Wang, T., Bloor, R. N., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/2/n01 · Cited by 46 · cited 4×
“We have seen much evidence that a major contributor to the ammonia in mouth-exhaled breath is oral bacteria/enzymatic activity and this has been demonstrated by washing the mouth with a dilute solution of urea whence the action of urea splitting organisms/enzymes results in ammonia [11].”
BackgroundMethodInfluentialSelf-citationWang, T., Carroll, W. D., Lenny, W., Boit, P., & Smith, D. C. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2285 · Cited by 29
Self-citation
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“These compounds may have exogeneous sources [103–107], be produced through medication [53, 108] or be released by bacteria in the airways [13, 14], the oral cavity [109–114] or in the gut [21, 54].”
BackgroundReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Self-citationClinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Metadata
- Authors
- Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2008-09-01
- Volume
- 2
- Issue
- 3
- Pages
- 037013
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2034754469
- Cited by
- 164
- References
- 31
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.