Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS

Open access
Schwarz, K, Filipiak, W, Amann, A·2009·Journal of Breath Research

Abstract

Proton-transfer-reaction mass spectrometry (PTR-MS) is a convenient technique for fast analysis of exhaled breath without prior sample preparation. Since compounds are not separated prior to analysis as in gas chromatography mass spectrometry (GC-MS), and since protonated molecules may fragment, relatively complex spectra may arise, which are not easily interpreted in a quantitative way. We calibrated 21 different compounds of importance for exhaled breath analysis, based on the respective pure standards diluted with nitrogen. These calibration measurements included determination of the fragmentation pattern of each compound under dry conditions and in the absence of CO(2). Even though the fragmentation pattern may be predicted in a qualitative manner, the quantitative details may depend on water and CO(2) content. This is exemplarily shown for isoprene. Out of the selected 21 compounds, 11 compounds showed substantial fragmentation (fragments proportion > 10%). Fragmentation of several volatile organic compounds (VOCs) in the drift tube of PTR-MS has been previously observed (Buhr et al 2002 Int. J. Mass Spectrom. 221 1-7; Taipale et al 2008 Atmos. Chem. Phys. Discuss. 8 9435-75; Hewitt et al 2003 J. Environ. Monit. 51-7; Warneke et al 2003 Environ. Sci. Technol. 37 2494-501; de Gouw and Warneke 2007 Mass Spectrom. Rev. 26 223-57; Pozo-Bayon et al 2008 J. Agric. Food Chem. 56 5278-84) and calibration factors for several compounds at corresponding mass-to-charge ratios have been calculated. In this paper, besides the calibration factors, the proportions of substantial fragments are also taken into account for a correct quantification in the case of overlapping signals. The spectrum of a mixture of the considered 21 compounds may be simulated. Conversely, the determination of concentrations from the spectrum of such a mixture is a linear optimization problem, whose solution is determined here using the simplex algorithm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1752-7155/3/2/027002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Schwarz, K., Filipiak, W., & Amann, A.
Venue
Journal of Breath Research
Published
2009-05-15
Volume
3
Issue
2
Pages
027002
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W2069149636
Cited by
158
References
1
FWCI
7.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. https://app.cochat.ai/papers/10.1088/1752-7155/3/2/027002
The paper
Schwarz, K., Filipiak, W., & Amann, A. (2009). Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. Journal of Breath Research. https://doi.org/10.1088/1752-7155/3/2/027002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.