The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS
Open accessAbstract
Proton-transfer-reaction mass spectrometry (PTR-MS) is a convenient technique for fast analysis of exhaled breath without prior sample preparation. Since compounds are not separated prior to analysis as in gas chromatography mass spectrometry (GC-MS), and since protonated molecules may fragment, relatively complex spectra may arise, which are not easily interpreted in a quantitative way. We calibrated 21 different compounds of importance for exhaled breath analysis, based on the respective pure standards diluted with nitrogen. These calibration measurements included determination of the fragmentation pattern of each compound under dry conditions and in the absence of CO(2). Even though the fragmentation pattern may be predicted in a qualitative manner, the quantitative details may depend on water and CO(2) content. This is exemplarily shown for isoprene. Out of the selected 21 compounds, 11 compounds showed substantial fragmentation (fragments proportion > 10%). Fragmentation of several volatile organic compounds (VOCs) in the drift tube of PTR-MS has been previously observed (Buhr et al 2002 Int. J. Mass Spectrom. 221 1-7; Taipale et al 2008 Atmos. Chem. Phys. Discuss. 8 9435-75; Hewitt et al 2003 J. Environ. Monit. 51-7; Warneke et al 2003 Environ. Sci. Technol. 37 2494-501; de Gouw and Warneke 2007 Mass Spectrom. Rev. 26 223-57; Pozo-Bayon et al 2008 J. Agric. Food Chem. 56 5278-84) and calibration factors for several compounds at corresponding mass-to-charge ratios have been calculated. In this paper, besides the calibration factors, the proportions of substantial fragments are also taken into account for a correct quantification in the case of overlapping signals. The spectrum of a mixture of the considered 21 compounds may be simulated. Conversely, the determination of concentrations from the spectrum of such a mixture is a linear optimization problem, whose solution is determined here using the simplex algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
The versatile use of exhaled volatile organic compounds in human health and disease
Boots, A. W., van Berkel, J. J. B. N., Dallinga, J. W., Smolinska, A., Wouters, E. F., & van Schooten, F. J. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027108 · Cited by 352
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citation
Metadata
- Authors
- Schwarz, K., Filipiak, W., & Amann, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2009-05-15
- Volume
- 3
- Issue
- 2
- Pages
- 027002
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2069149636
- Cited by
- 158
- References
- 1
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. https://app.cochat.ai/papers/10.1088/1752-7155/3/2/027002
- The paper
- Schwarz, K., Filipiak, W., & Amann, A. (2009). Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS. Journal of Breath Research. https://doi.org/10.1088/1752-7155/3/2/027002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.