The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Breath acetone monitoring by portable Si:WO3 gas sensors
Open accessAbstract
Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Self-citationNoninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Self-citationDeng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Semiconductor Gas Sensors: Dry Synthesis and Application
Tricoli, A., Righettoni, M., & Teleki, A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903801 · Cited by 543
Self-citationGrowth and decay of pulmonary function in healthy blacks and whites
Schoenberg, J. B., Beck, G. J., & Bouhuys, A. (1978) · Respiration Physiology · doi:10.1016/0034-5687(78)90063-4 · Cited by 396
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Self-citationIsoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Self-citation
Cited by
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Metadata
- Authors
- Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2012-08
- Volume
- 738
- Pages
- 69-75
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2140933253
- Cited by
- 317
- References
- 23
- FWCI
- 11.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath acetone monitoring by portable Si:WO3 gas sensors. https://app.cochat.ai/papers/10.1016/j.aca.2012.06.002
- The paper
- Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012). Breath acetone monitoring by portable Si:WO3 gas sensors. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2012.06.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.