Determining concentration patterns of volatile compounds in exhaled breath by PTR-MS
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Proton-transfer-reaction mass spectrometry (PTR-MS) is a convenient technique for fast analysis of exhaled breath without prior sample preparation. Since compounds are not separated prior to analysis as in gas chromatography mass spectrometry (GC-MS), and since protonated molecules may fragment, relatively complex spectra may arise, which are not easily interpreted in a quantitative way. We calibrated 21 different compounds of importance for exhaled breath analysis, based on the respective pure standards diluted with nitrogen. These calibration measurements included determination of the fragmentation pattern of each compound under dry conditions and in the absence of CO(2). Even though the fragmentation pattern may be predicted in a qualitative manner, the quantitative details may depend on water and CO(2) content. This is exemplarily shown for isoprene. Out of the selected 21 compounds, 11 compounds showed substantial fragmentation (fragments proportion > 10%). Fragmentation of several volatile organic compounds (VOCs) in the drift tube of PTR-MS has been previously observed (Buhr et al 2002 Int. J. Mass Spectrom. 221 1-7; Taipale et al 2008 Atmos. Chem. Phys. Discuss. 8 9435-75; Hewitt et al 2003 J. Environ. Monit. 51-7; Warneke et al 2003 Environ. Sci. Technol. 37 2494-501; de Gouw and Warneke 2007 Mass Spectrom. Rev. 26 223-57; Pozo-Bayon et al 2008 J. Agric. Food Chem. 56 5278-84) and calibration factors for several compounds at corresponding mass-to-charge ratios have been calculated. In this paper, besides the calibration factors, the proportions of substantial fragments are also taken into account for a correct quantification in the case of overlapping signals. The spectrum of a mixture of the considered 21 compounds may be simulated. Conversely, the determination of concentrations from the spectrum of such a mixture is a linear optimization problem, whose solution is determined here using the simplex algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Methods of Optimization
Fletcher, R. (2000) · Wiley eBooks · doi:10.1002/9781118723203 · Cited by 7,605
Practical methods of optimization
(1988) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(88)90129-2 · Cited by 5,818
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615 · cited 7×
“the standard formula for PTR-MS concentrations [27]:”
InfluentialDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096 · cited 1×
“potential [7–10].”
de Gouw, J., & Warneke, C. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20119 · Cited by 1,055
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727 · cited 3×
“and 2-propanol) the values in the literature vary over a wide range 30–130 ppb [14, 35].”
Anicich, V. G. (1993) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555940 · Cited by 581
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
de Gouw, J., Warneke, C., Karl, T., Eerdekens, G., van der Veen, C., & Fall, R. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00926-0 · Cited by 345 · cited 3×
“The water vapor level in the drift tube is influenced by the humidity of the sample itself and the water level in the ion source [28, 37, 40].”
Fall, R., Karl, T., Hansel, A., Jordan, A., & Lindinger, W. (1999) · Journal of Geophysical Research: Atmospheres · doi:10.1029/1999jd900144 · Cited by 333 · cited 1×
“In previous studies the fragmentation patterns (most abundant signals) for several compounds were investigated [1, 27, 38, 39].”
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“substance by consideration of its fragmentation pattern [15].”
BackgroundSelf-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationNoninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
The versatile use of exhaled volatile organic compounds in human health and disease
Boots, A. W., van Berkel, J. J. B. N., Dallinga, J. W., Smolinska, A., Wouters, E. F., & van Schooten, F. J. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027108 · Cited by 352
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citationVOC breath biomarkers in lung cancer
Saalberg, Y., & Wolff, M. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.05.013 · Cited by 293
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Self-citationFilipiak, W., Sponring, A., Baur, M. M., Filipiak, A., Ager, C., Wiesenhofer, H., Nagl, M., Troppmair, J., & Amann, A. (2012) · BMC Microbiology · doi:10.1186/1471-2180-12-113 · Cited by 252
Self-citationBuszewski, B., Ligor, T., Jezierski, T., Wenda-Piesik, A., Walczak, M., & Rudnicka, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6102-8 · Cited by 234
Filipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
“Acetone is a well-studied substance [2] and was suggested”
BackgroundSelf-citationThe network of plants volatile organic compounds
Vivaldo, G., Masi, E., Taiti, C., Caldarelli, G., & Mancuso, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-10975-x · Cited by 212
Nanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Physiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
“For further details regarding quantification and the underlying PTR-MS settings used the interested reader is referred to (Schwarz et al., 2009) and (King et al., 2009), respectively.”
BackgroundSelf-citationKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
Self-citationNoninvasive detection of lung cancer using exhaled breath
Fu, X., Li, M., Knipp, R. J., Nantz, M. H., & Bousamra, M. (2014) · Cancer Medicine · doi:10.1002/cam4.162 · Cited by 166
Metadata
- Authors
- Schwarz, K., Filipiak, W., & Amann, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2009-05-15
- Volume
- 3
- Issue
- 2
- Pages
- 027002
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2069149636
- Cited by
- 158
- References
- 45
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.