Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

The importance of methane breath testing: a review

Open access
de Lacy Costello, B P J, Ledochowski, M, Ratcliffe, N M · 2013 · Journal of Breath Research

Abstract

Sugar malabsorption in the bowel can lead to bloating, cramps, diarrhea and other symptoms of irritable bowel syndrome as well as affecting absorption of other nutrients. The hydrogen breath test is now a well established noninvasive test for assessing malabsorption of sugars in the small intestine. However, there are patients who can suffer from the same spectrum of malabsorption issues but who produce little or no hydrogen, instead producing relatively large amounts of methane. These patients will avoid detection with the traditional breath test for malabsorption based on hydrogen detection. Likewise the hydrogen breath test is an established method for small intestinal bacterial overgrowth (SIBO) diagnoses. Therefore, a number of false negatives would be expected for patients who solely produce methane. Usually patients produce either hydrogen or methane, and only rarely there are significant co-producers, as typically the methane is produced at the expense of hydrogen by microbial conversion of carbon dioxide. Various studies show that methanogens occur in about a third of all adult humans; therefore, there is significant potential for malabsorbers to remain undiagnosed if a simple hydrogen breath test is used. As an example, the hydrogen-based lactose malabsorption test is considered to result in about 5-15% false negatives mainly due to methane production. Until recently methane measurements were more in the domain of research laboratories, unlike hydrogen analyses which can now be undertaken at a relatively low cost mainly due to the invention of reliable electrochemical hydrogen sensors. More recently, simpler lower cost instrumentation has become commercially available which can directly measure both hydrogen and methane simultaneously on human breath. This makes more widespread clinical testing a realistic possibility. The production of small amounts of hydrogen and/or methane does not normally produce symptoms, whereas the production of higher levels can lead to a wide range of symptoms ranging from functional disorders of the bowel to low level depression. It is possible that excess methane levels may have more health consequences than excess hydrogen levels. This review describes the health consequences of methane production in humans and animals including a summary of the state of the art in detection methods. In conclusion, the combined measurement of hydrogen and methane should offer considerable improvement in the diagnosis of malabsorption syndromes and SIBO when compared with a single hydrogen breath test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1752-7155/7/2/024001

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 233

Metadata

Authors
de Lacy Costello, B. P. J., Ledochowski, M., & Ratcliffe, N. M.
Venue
Journal of Breath Research
Published
2013-03-08
Volume
7
Issue
2
Pages
024001
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W2079987062
Cited by
233
References
6
FWCI
22.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The importance of methane breath testing: a review. https://app.cochat.ai/papers/10.1088/1752-7155/7/2/024001
The paper
de Lacy Costello, B. P. J., Ledochowski, M., & Ratcliffe, N. M. (2013). The importance of methane breath testing: a review. Journal of Breath Research. https://doi.org/10.1088/1752-7155/7/2/024001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.