Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Mass spectrometry for real-time quantitative breath analysis

Open access
Smith, David, Španěl, Patrik, Herbig, Jens, Beauchamp, Jonathan·2014·Journal of Breath Research

Abstract

Breath analysis research is being successfully pursued using a variety of analytical methods, prominent amongst which are gas chromatography with mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the fast flow and flow-drift tube techniques called selected ion flow tube mass spectrometry, SIFT-MS, and proton transfer reaction mass spectrometry, PTR-MS. In this paper the case is made for real-time breath analysis by obviating sample collection into bags or onto traps that can suffer from partial degradation of breath metabolites or the introduction of impurities. Real-time analysis of a broad range of volatile chemical compounds can be best achieved using SIFT-MS and PTR-MS, which are sufficiently sensitive and rapid to allow the simultaneous analyses of several trace gas metabolites in single breath exhalations. The basic principles and the ion chemistry that underpin these two analytical techniques are briefly described and the differences between them, including their respective strengths and weaknesses, are revealed, especially with reference to the analysis of the complex matrix that is exhaled breath. A recent innovation is described that combines time-of-flight mass spectrometry with the proton transfer flow-drift tube reactor, PTR-TOFMS, which provides greater resolution in the analytical mass spectrometer and allows separation of protonated isobaric molecules. Examples are presented of some recent data that well illustrate the quality and real-time feature of SIFT-MS and PTR-MS for the analysis of exhaled breath for physiological/biochemical/pharmacokinetics studies and for the identification and quantification of biomarkers relating to specific disease states.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1752-7155/8/2/027101

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 174

Metadata

Authors
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J.
Venue
Journal of Breath Research
Published
2014-03-28
Volume
8
Issue
2
Pages
027101
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W1969139946
Cited by
174
References
2
FWCI
10.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mass spectrometry for real-time quantitative breath analysis. https://app.cochat.ai/papers/10.1088/1752-7155/8/2/027101
The paper
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014). Mass spectrometry for real-time quantitative breath analysis. Journal of Breath Research. https://doi.org/10.1088/1752-7155/8/2/027101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.