Mass spectrometry for real-time quantitative breath analysis
Open accessThe DOI matches its Crossref record; 141 of the 141 references it cites were found in a registry or an index.
Abstract
Breath analysis research is being successfully pursued using a variety of analytical methods, prominent amongst which are gas chromatography with mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the fast flow and flow-drift tube techniques called selected ion flow tube mass spectrometry, SIFT-MS, and proton transfer reaction mass spectrometry, PTR-MS. In this paper the case is made for real-time breath analysis by obviating sample collection into bags or onto traps that can suffer from partial degradation of breath metabolites or the introduction of impurities. Real-time analysis of a broad range of volatile chemical compounds can be best achieved using SIFT-MS and PTR-MS, which are sufficiently sensitive and rapid to allow the simultaneous analyses of several trace gas metabolites in single breath exhalations. The basic principles and the ion chemistry that underpin these two analytical techniques are briefly described and the differences between them, including their respective strengths and weaknesses, are revealed, especially with reference to the analysis of the complex matrix that is exhaled breath. A recent innovation is described that combines time-of-flight mass spectrometry with the proton transfer flow-drift tube reactor, PTR-TOFMS, which provides greater resolution in the analytical mass spectrometer and allows separation of protonated isobaric molecules. Examples are presented of some recent data that well illustrate the quality and real-time feature of SIFT-MS and PTR-MS for the analysis of exhaled breath for physiological/biochemical/pharmacokinetics studies and for the identification and quantification of biomarkers relating to specific disease states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615 · cited 2×
“These observations were subsequently compared with exhaled breath profiles after oral administration of iso-propanol, via real-time analysis, in two review articles by Lindinger and coworkers that addressed diverse applications of the PTR-MS technique [8, 133].”
BackgroundMethodDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801 · cited 5×
“procedures and the numerous breath analysis studies carried out since its inception, the reader is referred to the several review papers [4, 5, 33, 39].”
BackgroundInfluentialSelf-citationLindinger, W., & Jordan, A. (1998) · Chemical Society Reviews · doi:10.1039/a827347z · Cited by 751 · cited 2×
“These observations were subsequently compared with exhaled breath profiles after oral administration of iso-propanol, via real-time analysis, in two review articles by Lindinger and coworkers that addressed diverse applications of the PTR-MS technique [8, 133].”
BackgroundMethodProton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727 · cited 7×
“This led to what is now known as proton-transfer-reaction mass spectrometry, PTR-MS, which focused on the use of H3O+, hydronium, as reagent species for proton transfer reaction with analytes in the sample gas [26].”
BackgroundMethodInfluentialJordan, A., Haidacher, S., Hanel, G., Hartungen, E., Märk, L., Seehauser, H., Schottkowsky, R., Sulzer, P., & Märk, T. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.07.005 · Cited by 653 · cited 2×
“PTR-TOFMS instruments have a mass resolving power of >5000 m/ m [59].”
BackgroundMethodAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Su, T., & Bowers, M. T. (1973) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(73)80104-4 · Cited by 526
Breath gas aldehydes as biomarkers of lung cancer
Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W. (2010) · International Journal of Cancer · doi:10.1002/ijc.24970 · Cited by 513
The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
Adams, N. G., & Smith, D. (1976) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(76)80133-7 · Cited by 397 · cited 1×
“The origins of SIFT-MS [17], first developed in 1996 [18], can be traced back to the conception and development of the selected ion flow tube, SIFT, technique at the University of Birmingham, UK in the mid-1970s [19].”
MethodSelf-citationBreath Analysis: Potential for Clinical Diagnosis and Exposure Assessment
Cao, W., & Duan, Y. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063545 · Cited by 391
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citationCurrent status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Self-citationFundamentals and applications of needle trap devices
Lord, H. L., Zhan, W., & Pawliszyn, J. B. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.020 · Cited by 309
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Proton transfer reaction rate constants between hydronium ion (H3O+) and volatile organic compounds
Zhao, J., & Zhang, R. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.01.019 · Cited by 309 · cited 1×
“So the reaction of H3O+ with each M must be studied under the actual conditions of the flow tube or FDT reactor in order to construct a functioning and accurate kinetics library entry for each compound to be analysed [5, 6, 32, 43, 44].”
BackgroundBreath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Exhaled volatile organic compounds identify patients with colorectal cancer
Altomare, D. F., Di Lena, M., Porcelli, F., Trizio, L., Travaglio, E., Tutino, M., Dragonieri, S., Memeo, V, & de Gennaro, G. (2013) · Journal of British Surgery · doi:10.1002/bjs.8942 · Cited by 289
Collisions in a noncentral field: A variational and trajectory investigation of ion–dipole capture
Chesnavich, W. J., Su, T., & Bowers, M. T. (1980) · The Journal of Chemical Physics · doi:10.1063/1.439409 · Cited by 287 · cited 1×
“The reaction rate is therefore close to the collisional rate and can be calculated using the physical properties of the reactant molecule (polarizability and dipole moment [108, 109]) and the very well-defined conditions in the FDT reaction chamber.”
MethodComparison of the Volatile Organic Compounds Present in Human Odor Using Spme-GC/MS
Curran, A. M., Rabin, S. I., Prada, P. A., & Furton, K. G. (2005) · Journal of Chemical Ecology · doi:10.1007/s10886-005-5801-4 · Cited by 281 · cited 6×
“Other analytical techniques that also play important roles in breath analysis, especially gas chromatography mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the development of solid state sensors were well represented at the conference.”
MethodInfluentialLung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Evaluation of Biomarkers and Surrogate Endpoints in Chronic Disease
(2010) · National Academies Press eBooks · doi:10.17226/12869 · Cited by 276 · cited 1×
“So what is a biomarker? A widely accepted definition, used by the National Institute of Health (NIH), [1] is: ‘a characteristic that is objectively measured and evaluated as an indicator of normal biological processes, pathogenic processes, or pharmacologic responses to an intervention.”
BackgroundBuhr, K., van Ruth, S., & Delahunty, C. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00896-5 · Cited by 271 · cited 1×
“So the reaction of H3O+ with each M must be studied under the actual conditions of the flow tube or FDT reactor in order to construct a functioning and accurate kinetics library entry for each compound to be analysed [5, 6, 32, 43, 44].”
BackgroundDweik, R. A., Sorkness, R. L., Wenzel, S., Hammel, J., Curran-Everett, D., Comhair, S. A. A., Bleecker, E., Busse, W., Calhoun, W. J., Castro, M., et al. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200905-0695oc · Cited by 270
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264 · cited 1×
“King and colleagues [148, 149] have employed real-time PTRMS breath analysis extensively to intricately characterize the endogenous production and distribution within the body of several key compounds, in particular exhaled isoprene, which had first been investigated using PTR-MS by Karl and colleagues in 2001 [150].”
Volatile biomarkers in the breath of women with breast cancer
Phillips, M., Cataneo, R. N., Saunders, C., Hope, P., Schmitt, P., & Wai, J. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/2/026003 · Cited by 253
Jordan, A., Haidacher, S., Hanel, G., Hartungen, E., Herbig, J., Märk, L., Schottkowsky, R., Seehauser, H., Sulzer, P., & Märk, T. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.06.006 · Cited by 249
Self-citationAldehydes in Exhaled Breath Condensate of Patients with Chronic Obstructive Pulmonary Disease
Corradi, M., Rubinstein, I., Andreoli, R., Manini, P., Caglieri, A., Poli, D., Alinovi, R., & Mutti, A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1253oc · Cited by 242
On the use of Tedlar® bags for breath-gas sampling and analysis
Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046001 · Cited by 236
Self-citationBuszewski, B., Ligor, T., Jezierski, T., Wenda-Piesik, A., Walczak, M., & Rudnicka, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6102-8 · Cited by 234
The importance of methane breath testing: a review
de Lacy Costello, B. P. J., Ledochowski, M., & Ratcliffe, N. M. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/2/024001 · Cited by 233
Filipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
Increased breath biomarkers of oxidative stress in diabetes mellitus
Phillips, M., Cataneo, R. N., Cheema, T., & Greenberg, J. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.02.025 · Cited by 212
Applications of breath gas analysis in medicine
Amann, A., Poupart, G., Telser, S., Ledochowski, M., Schmid, A., & Mechtcheriakov, S. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.08.010 · Cited by 208 · cited 1×
“In another scenario, passive sampling has been utilized to monitor isoprene levels (amongst other compounds) in sleeping subjects, in which concentration fluctuations were found to closely follow heartrate and leg movements [139, 140].”
BackgroundBlake, R. S., Whyte, C., Hughes, C. O., et al. (2004) · Analytical Chemistry · doi:10.1021/ac0498260 · Cited by 205
On-line breath analysis with PTR-TOF
Herbig, J., Müller, M., Schallhart, S., Titzmann, T., Graus, M., & Hansel, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027004 · Cited by 205
Self-citationPhysiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
Blood and breath levels of selected volatile organic compounds in healthy volunteers
Mochalski, P., King, J., Klieber, M., Unterkofler, K., Hinterhuber, H., Baumann, M., & Amann, A. (2013) · The Analyst · doi:10.1039/c3an36756h · Cited by 190
King, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
Španěl, P., Smith, D., Holland, T. A., Singary, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j · Cited by 189
Self-citationThe Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960731)10:10<1183::aid-rcm641>3.0.co;2-3 · Cited by 177 · cited 1×
“The origins of SIFT-MS [17], first developed in 1996 [18], can be traced back to the conception and development of the selected ion flow tube, SIFT, technique at the University of Birmingham, UK in the mid-1970s [19].”
MethodSelf-citationLabows, J. N., McGinley, K. J., Webster, G. F., & Leyden, J. J. (1980) · Journal of Clinical Microbiology · doi:10.1128/jcm.12.4.521-526.1980 · Cited by 168 · cited 1×
“To our knowledge, it has not been detected by GC-MS using the conventional EI method of ion production [94].”
MethodAnalysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Self-citationKumar, S., Huang, J., Abbassi-Ghadi, N., Španěl, P., Smith, D., & Hanna, G. B. (2013) · Analytical Chemistry · doi:10.1021/ac4010309 · Cited by 164 · cited 1×
“of gastric content [75], urine [76] and the exhaled breath [77] of patients suffering from gastro-oesophageal cancer.”
BackgroundSelf-citationExhaled methyl nitrate as a noninvasive marker of hyperglycemia in type 1 diabetes
Novak, B. J., Blake, D. R., Meinardi, S., Rowland, F. S., Pontello, A., Cooper, D. M., & Galassetti, P. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706533104 · Cited by 163
Harrison, G., Critchley, A. D. J., Mayhew, C. A., & Thompson, J. M. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg271 · Cited by 161
Jordan, A., Hansel, A., Holzinger, R., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04236-e · Cited by 158 · cited 1×
“Indeed, several followup studies investigated the volatile breath constituents of smokers, the first of which compared exhaled concentrations of the compounds acetonitrile and benzene between smokers and non-smokers [126].”
BackgroundEndogenous Production of Methanol after the Consumption of Fruit
Lindinger, W., Taucher, J. A., Jordan, A., Hansel, A., & Vogel, W. (1997) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.1997.tb03862.x · Cited by 157
Trefz, P., Schmidt, M., Oertel, P., Obermeier, J., Brock, B., Kamysek, S., Dunkl, J., Zimmermann, R., Schubert, J. K., & Miekisch, W. (2013) · Analytical Chemistry · doi:10.1021/ac402298v · Cited by 155
Volatile Biomarkers : Non-Invasive Diagnosis in Physiology and Medicine
Amann, A., & Smith, D. C. (2013) · Cited by 150
Self-citationFærch, K., Borch‐Johnsen, K., Vaag, A. A., Jørgensen, T., & Witte, D. R. (2010) · Diabetologia · doi:10.1007/s00125-010-1673-4 · Cited by 149
Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046006 · Cited by 149
Enderby, B., Smith, D. C., Carroll, W. D., & Lenney, W. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.20963 · Cited by 148
Self-citationMeasurement of endogenous acetone and isoprene in exhaled breath during sleep
King, J., Kupferthaler, A., Frauscher, B., Hackner, H., Unterkofler, K., Teschl, G., Hinterhuber, H., Amann, A., & Högl, B. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/413 · Cited by 144
Španěl, P., & Smith, D. C. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00246-2 · Cited by 142
Self-citationOn-line Monitoring of End-tidal Propofol Concentration in Anesthetized Patients
Takita, A., Masui, K., & Kazama, T. (2007) · Anesthesiology · doi:10.1097/01.anes.0000264745.63275.59 · Cited by 137
Turner, C., Parekh, B. K., Walton, C., Španěl, P., Smith, D. C., & Evans, M. L. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3402 · Cited by 135
Self-citationTaucher, J., Hansel, A., Jordan, A., & Lindinger, W. (1996) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf960640e · Cited by 133 · cited 1×
“At this stage it was becoming clear that breath analysis was not just relevant for medical applications, but had a high potential for food research, with the first report on food-related breath analysis using PTR-MS for the investigation of the release and metabolism of volatiles after ingestion of garlic [131].”
BackgroundChemical input – Sensory output: Diverse modes of physiology–flavour interaction
Buettner, A., & Beauchamp, J. D. (2010) · Food Quality and Preference · doi:10.1016/j.foodqual.2010.01.008 · Cited by 129
Self-citationThe suitability of Tedlar bags for breath sampling in medical diagnostic research
Steeghs, M. M. L., Cristescu, S. M., & Harren, F. J. M. (2006) · Physiological Measurement · doi:10.1088/0967-3334/28/1/007 · Cited by 126 · cited 1×
“main advantage of real-time direct analysis of breath is the reduced likelihood of sample adulteration through artefacts of oxidation or environmental contaminants, or from losses, as is frequently encountered in off-line analysis of breath gas samples collected in receptacles such as polymer bags [120, 121].”
BackgroundBeauchamp, J. D. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/3/037103 · Cited by 124 · cited 6×
“Other analytical techniques that also play important roles in breath analysis, especially gas chromatography mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the development of solid state sensors were well represented at the conference.”
BackgroundInfluentialSelf-citationDirect, rapid quantitative analyses of BVOCs using SIFT-MS and PTR-MS obviating sample collection
Smith, D. C., & Španěl, P. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.05.001 · Cited by 122 · cited 2×
“In general, the strategy of applying different precursor ions is just a partial solution and can only be used to separate some isobaric compounds [57, 58] including aldehydes and ketones [33, 39], but not structural isomers.”
BackgroundSelf-citationTaucher, J., Hansel, A., Jordan, A., Fall, R., Futrell, J. H., & Lindinger, W. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199707)11:11<1230::aid-rcm3>3.0.co;2-z · Cited by 120 · cited 1×
“Further studies by that team included profiling propanol concentrations in the breath of healthy volunteers (a mean value of 150 ppbv was reported [129]) and investigating isoprene, one of the most abundant endogenous hydrocarbons, reporting for the first time that children have much lower exhaled isoprene concentrati…”
BackgroundKing, J., Unterkofler, K., Teschl, G., Teschl, S., Koc, H., Hinterhuber, H., & Amann, A. (2011) · Journal of Mathematical Biology · doi:10.1007/s00285-010-0398-9 · Cited by 117 · cited 1×
“These studies have led to detailed mathematical models of compounds such as isoprene and acetone [84, 85, 91, 151], which pave the way for standardizing breath analysis through prior knowledge of typical physiological levels of these endogenous compounds.”
BackgroundAcetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4–83 years
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/011001 · Cited by 116
Self-citationCan volatile compounds in exhaled breath be used to monitor control in diabetes mellitus?
Smith, D. C., Španěl, P., Fryer, A. A., Hanna, F., & Ferns, G. A. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/2/022001 · Cited by 114
Self-citationAmbient analysis of trace compounds in gaseous media by SIFT-MS
Smith, D. C., & Španěl, P. (2011) · The Analyst · doi:10.1039/c1an15082k · Cited by 113 · cited 4×
“In general, the strategy of applying different precursor ions is just a partial solution and can only be used to separate some isobaric compounds [57, 58] including aldehydes and ketones [33, 39], but not structural isomers.”
BackgroundMethodInfluentialSelf-citationMultibed Needle Trap Devices for on Site Sampling and Preconcentration of Volatile Breath Biomarkers
Mieth, M., Kischkel, S., Schubert, J. K., Hein, D., & Miekisch, W. (2009) · Analytical Chemistry · doi:10.1021/ac9009269 · Cited by 108
A quantitative study of the influence of inhaled compounds on their concentrations in exhaled breath
Španěl, P., Dryahina, K., & Smith, D. C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/1/017106 · Cited by 106 · cited 2×
“Now, a quantitative approach to this has recently been taken using SIFT-MS to directly analyse sequential exhalations/inhalations via the mouth and nose [90].”
BackgroundMethodSelf-citationTrefz, P., Kischkel, S., Hein, D., James, E. S., Schubert, J. K., & Miekisch, W. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.077 · Cited by 105
Smith, D. C., Wang, T., Pysanenko, A., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3434 · Cited by 105
Self-citationŠpaněl, P., & Smith, D. C. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.265 · Cited by 104
Self-citationBerichte des naturwissenschaftlich-medizinischen Vereins in Innsbruck
(1893) · Rendiconti del Circolo Matematico di Palermo Series 2 · doi:10.1007/bf03017643 · Cited by 100
Buffered end-tidal (BET) sampling—a novel method for real-time breath-gas analysis
Herbig, J., Titzmann, T., Beauchamp, J. D., Kohl, I., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037008 · Cited by 97
Self-citationKusano, M., Mendez, E. A., & Furton, K. G. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4950-2 · Cited by 96 · cited 6×
“Other analytical techniques that also play important roles in breath analysis, especially gas chromatography mass spectrometry, GC-MS, ion mobility spectrometry, IMS, and the development of solid state sensors were well represented at the conference.”
MethodInfluentialMorisco, F., Aprea, E., Lembo, V., Fogliano, V., Vitaglione, P., Mazzone, G., Cappellin, L., Gasperi, F., Masone, S., Palma, G. D. D., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059658 · Cited by 96
Hydrogen cyanide, a volatile biomarker ofPseudomonas aeruginosainfection
Smith, D. C., Španěl, P., Gilchrist, F. J., & Lenney, W. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/4/044001 · Cited by 95
Self-citationPhase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data
Schwoebel, H., Schubert, R., Sklorz, M., Kischkel, S., Zimmermann, R., Schubert, J. K., & Miekisch, W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5173-2 · Cited by 94 · cited 1×
“This is important when studying physiological changes, which can occur on the scale of minutes or even seconds, such as during exercise [83], and can be used for metabolic monitoring [146, 147].”
BackgroundHuang, J., Kumar, S., Abbassi‐Ghadi, N., Španěl, P., Smith, D. C., & Hanna, G. B. (2013) · Analytical Chemistry · doi:10.1021/ac4000656 · Cited by 94 · cited 1×
“of gastric content [75], urine [76] and the exhaled breath [77] of patients suffering from gastro-oesophageal cancer.”
BackgroundSelf-citationEnergy dependencies of the proton transfer reactions
Hansel, A., Singer, W., Wisthaler, A., Schwarzmann, M., & Lindinger, W. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00128-6 · Cited by 93
Beauchamp, J. D., Kirsch, F., & Buettner, A. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/2/026006 · Cited by 91 · cited 3×
“Reproduced from [144] by permission of IOP Publishing.”
BackgroundMethodInfluentialSelf-citationScotter, J. M., Langford, V. S., Wilson, P. F., McEwan, M. J., & Chambers, S. T. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.02.022 · Cited by 87
Španěl, P., Davies, S., & Smith, D. C. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19980630)12:12<763::aid-rcm229>3.0.co;2-s · Cited by 85
Self-citationTrefz, P., Rösner, L., Hein, D., Schubert, J. K., & Miekisch, W. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6781-9 · Cited by 83
Human Breath Analysis May Support the Existence of Individual Metabolic Phenotypes
Sinues, P., Kohler, M., & Zenobi, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059909 · Cited by 82
Hansel, A., Jordan, A., Warneke, C., Holzinger, R., & Lindinger, W. (1998) · Rapid Communications in Mass Spectrometry · Cited by 82
Samara, M. A., Tang, W. H. W., Cikach, F. S., Gul, Z., Tranchito, L. J., Paschke, K. M., Viterna, J., Wu, Y., Laskowski, D. M., & Dweik, R. A. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.033 · Cited by 81
Secondary electrospray ionization-mass spectrometry: breath study on a control group
Martínez-Lozano, P., Zingaro, L., Finiguerra, A., & Cristoni, S. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/1/016002 · Cited by 79
King, J., Unterkofler, K., Teschl, G., Teschl, S., Mochalski, P., Koc, H., Hinterhuber, H., & Amann, A. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/1/016005 · Cited by 78
The concentration distributions of some metabolites in the exhaled breath of young adults
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/2/026001 · Cited by 78
Self-citationŠpaněl, P., & Smith, D. C. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046003 · Cited by 75 · cited 1×
“This is exemplified by the simultaneous analyses of propanol, acetaldehyde and carbon dioxide in exhaled breath and cell culture headspace [71, 78, 79], which in SIFT-MS analyses often lead to ions of (nominally) the same m/z value of the analyte ions, as explained in detail in [79].”
BackgroundSelf-citationGilchrist, F. J., Bright-Thomas, R. J., Jones, A. M., Smith, D. C., Španěl, P., Webb, A. K., & Lenney, W. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/2/026010 · Cited by 75
Self-citationEnderby, B., Lenney, W., Brady, M., Emmett, C., Španěl, P., & Smith, D. C. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/3/036001 · Cited by 74
Self-citationDrug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation
Kamysek, S., Fuchs, P., Schwoebel, H., Roesner, J. P., Kischkel, S., Wolter, K., Loeseken, C., Schubert, J. K., & Miekisch, W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5099-8 · Cited by 74
Storer, M., Dummer, J. F., Lunt, H., Scotter, J., McCartin, F., Cook, J., Swanney, M. P., Kendall, D., Logan, F. J., & Epton, M. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046011 · Cited by 73
Dryahina, K., Španěl, P., Pospíšilová, V., Sovová, K., Hrdlička, L., Machková, N., Lukáš, M., & Smith, D. C. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6660 · Cited by 72
Self-citationSulé-Suso, J., Pysanenko, A., Španěl, P., & Smith, D. C. (2009) · The Analyst · doi:10.1039/b916158a · Cited by 70
Self-citationSulzer, P., Edtbauer, A., Hartungen, E., Jürschik, S., Jordan, A., Hanel, G., Feil, S., Jaksch, S., Märk, L., & Märk, T. D. (2012) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2012.05.003 · Cited by 69 · cited 3×
“In terms of sensitivity, the current PTR-TOF 8000 instruments (IONICON Analytik GmbH, Austria) typically achieve ∼150 cps per 1 ppbv neutral analyte [113], which is considerably higher than the SIFT-MS (10 cps ppbv–1) but is not quite comparable to that of the high sensitivity PTRQMS 500 system (400 cps ppbv–1).”
BackgroundMethodŠpaněl, P., & Smith, D. C. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00253-7 · Cited by 69 · cited 2×
“Also, mass discrimination against larger m/z ions in the analytical quadrupole mass spectrometer [61, 69] and the formation of hydrated reagent and analyte ions have been thoroughly investigated and accounted for in the analytical software providing analyses that do not require constant calibration of the instrument f…”
MethodSelf-citationThe role of mathematical modeling in VOC analysis using isoprene as a prototypic example
Koc, H., King, J., Teschl, G., Unterkofler, K., Teschl, S., Mochalski, P., Hinterhuber, H., & Amann, A. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/3/037102 · Cited by 68
Variation in hydrogen cyanide production between different strains ofPseudomonas aeruginosa
Gilchrist, F. J., Alcock, A., Belcher, J., Brady, M., Jones, A. M., Smith, D. C., Španěl, P., Webb, K., & Lenney, W. (2011) · European Respiratory Journal · doi:10.1183/09031936.00166510 · Cited by 67 · cited 1×
“A detailed study of this ion chemistry [95] has allowed the required kinetics library entry to be constructed which, in turn, has allowed in vitro and in vivo studies of HCN over a decade in the headspace of a variety of PA culture types, planktonic and biofilm [96], and significant numbers of genetically identified P…”
BackgroundSelf-citationMulti-capillary-column proton-transfer-reaction time-of-flight mass spectrometry
Ruzsányi, V., Fischer, L., Herbig, J., Ager, C., & Amann, A. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.09.072 · Cited by 67
Self-citationApplications of proton transfer reactions to gas analysis
Lagg, A., Taucher, J. A., Hansel, A., & Lindinger, W. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)03965-8 · Cited by 66 · cited 1×
“One of these studies relates to the (off-line) analysis of methanol, ethanol and acetone in breath samples (collected in bags) after consumption of alcohol and fruit and in relation to diabetes: this study might be considered the first PTR-MS-related breath investigation, albeit using a SIFDT-MS instrument [123].”
BackgroundPysanenko, A., Španěl, P., & Smith, D. C. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046004 · Cited by 65
Self-citationMetabolic monitoring and assessment of anaerobic threshold by means of breath biomarkers
Schubert, R., Schwoebel, H., Mau‐Moeller, A., Behrens, M., Fuchs, P., Sklorz, M., Schubert, J. K., Bruhn, S., & Miekisch, W. (2012) · Metabolomics · doi:10.1007/s11306-012-0408-6 · Cited by 64
Smith, D. C., Pysanenko, A., & Španěl, P. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.11.007 · Cited by 62 · cited 5×
“The absolute accuracy of SIFT-MS has been validated to be better than 10% for several compounds [61, 66, 67] without the need for external standards, as long as the sample and carrier gas flow rates and flow tube temperature are accurately known and mass discrimination and diffusion effects are properly accounted for.”
BackgroundMethodInfluentialSelf-citationQuantification of hydrogen cyanide in humid air by selected ion flow tube mass spectrometry
Španěl, P., Wang, T., & Smith, D. C. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1566 · Cited by 61
Self-citationPotential of breath and skin analysis for monitoring blood glucose concentration in diabetes
Turner, C. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.11.31 · Cited by 61
Multifaceted attributes of dairy propionibacteria: a review
Poonam, P., Pophaly, S. D., Tomar, S. K., De, S., & Singh, R. (2012) · World Journal of Microbiology and Biotechnology · doi:10.1007/s11274-012-1117-z · Cited by 59
Grabowska-Polanowska, B., Mochalski, P., Śliwka, I., & Amann, A. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/2/026002 · Cited by 59 · cited 1×
“Thus, identification of both isobaric and isomeric compounds can be achieved with a reasonable degree of certainty as long as they are separated in the GC column, which is usually accomplished using columns of different polarity, but calibration is needed that also involves the GC elution times (retention times or ind…”
BackgroundDryahina, K., Smith, D. C., & Španěl, P. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4513 · Cited by 57
Self-citationSimply breath-taking? Developing a strategy for consistent breath sampling
Beauchamp, J. D., & Pleil, J. D. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/4/042001 · Cited by 53 · cited 2×
“As a result, even without the identification of the compound, a coarse quantification is possible that usually yields results within ∼20% accuracy [9, 110], thus enabling at least order of magnitude determinations for compound concentrations without the need for calibration, when potential fragmentation is accounted f…”
BackgroundSelf-citationGilchrist, F. J., Razavi, C., Webb, A. K., Jones, A. M., Španěl, P., Smith, D. C., & Lenney, W. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036004 · Cited by 52
Self-citationAlonso, M., Godayol, A., Anticó, E., & Sánchez, J. M. (2011) · Journal of Separation Science · doi:10.1002/jssc.201100381 · Cited by 46
Diagnostic value of exhaled nitric oxide in childhood asthma and allergy
Sachs‐Olsen, C., Carlsen, K., Mowinckel, P., Håland, G., Devulapalli, C. S., Munthe‐Kaas, M. C., & Carlsen, K. ‐. (2010) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2009.00965.x · Cited by 46
Dolch, M. E., Hornuß, C., Klocke, C., Praun, S., Villinger, J., Denzer, W., Schelling, G., & Schubert, S. (2012) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-012-1654-2 · Cited by 45
Smith, D. C., Španěl, P., Thompson, J. M., Rajan, B., Cocker, J., & Rolfe, P. J. (1998) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1998.10389161 · Cited by 44
Self-citationFirst observation of a potential non-invasive breath gas biomarker for kidney function
Kohl, I., Beauchamp, J. D., Cakar, F., Herbig, J., Dunkl, J., Tietje, O., Tiefenthaler, M., Boesmueller, C., Wisthaler, A., Breitenlechner, M., et al. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/1/017110 · Cited by 43
Self-citationHuman Breath Gas Analysis in the Screening of Gestational Diabetes Mellitus
Halbritter, S., Fedrigo, M., Höllriegl, V., Szymczak, W., Maier, J. M., Ziegler, A., & Hummel, M. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0076 · Cited by 42 · cited 1×
“In one study, exhaled breath has been investigated for indications of gestational diabetes mellitus (GDM) via the oral glucose intolerance test [142].”
MethodClinical aspects of using exhaled NO in asthma diagnosis and management
Lúðvíksdóttir, D., Diamant, Z., Alving, K., Bjermer, L. H., & Malinovschi, A. (2012) · The Clinical Respiratory Journal · doi:10.1111/crj.12001 · Cited by 42
Kleeblatt, J., Schubert, J. K., & Zimmermann, R. (2014) · Analytical Chemistry · doi:10.1021/ac5039829 · Cited by 41
Quantification of passive smoking using proton-transfer-reaction mass spectrometry
Prazeller, P., Karl, T., Jordan, A., Holzinger, R., Hansel, A., & Lindinger, W. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14153-2 · Cited by 40 · cited 1×
“A subsequent study by the same group attempted to quantify the degree of exposure to cigarette smoke from passive smoking based on acetonitrile levels in exhaled breath [128].”
BackgroundŠpaněl, P., & Smith, D. C. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.07.021 · Cited by 40
Self-citationDolch, M. E., Frey, L., Hornuß, C., Schmoelz, M., Praun, S., Villinger, J., & Schelling, G. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037010 · Cited by 39
Tanda, N., Hinokio, Y., Washio, J., Takahashi, N., & Koseki, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/4/046008 · Cited by 36
Guallar-Hoyas, C., Turner, M. A., Blackburn, G. J., Wilson, I. D., & Thomas, C. L. P. (2012) · Bioanalysis · doi:10.4155/bio.12.193 · Cited by 36
Smith, D. C., Pysanenko, A., & Španěl, P. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4016 · Cited by 34
Self-citationl, P. P., & Smith, D. C. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(20000430)14:8<646::aid-rcm926>3.0.co;2-7 · Cited by 31
Self-citationOn‐line analysis of diesel engine exhaust gases by selected ion flow tube mass spectrometry
Smith, D. C., Španěl, P., Dabill, D. W., Cocker, J., & Rajan, B. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1702 · Cited by 27
Self-citationReal-time metabolic monitoring with proton transfer reaction mass spectrometry
Winkler, K., Herbig, J., & Kohl, I. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/036006 · Cited by 26 · cited 1×
“Another recent realtime PTR-MS breath analysis study focused on metabolic monitoring of ethanol, as discussed below [143].”
BackgroundSelf-citationSmith, D. C., Pysanenko, A., & Španěl, P. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4481 · Cited by 26
Self-citationGhosh, C., Maity, A., Banik, G. D., Som, S., Chakraborty, A., Selvan, C., Ghosh, S., Ghosh, B., Chowdhury, S., & Pradhan, M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/036001 · Cited by 25
Account: On the Features, Successes and Challenges of Selected Ion Flow Tube Mass Spectrometry
Španěl, P., & Smith, D. C. (2013) · European Journal of Mass Spectrometry · doi:10.1255/ejms.1240 · Cited by 23 · cited 1×
“A SWOT (strengths, weaknesses, opportunities and threats) analysis of the SIFT-MS approach to breath analysis research is presented in a recent Account article [86].”
MethodSelf-citationTan, B. K., Smith, D. C., Španěl, P., & Davies, S. J. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/1/017109 · Cited by 11
Self-citationModel Based Determination of Detection Limits for Proton Transfer Reaction Mass Spectrometer
Amann, A., Schwarz, K., Wimmer, G., & Witkovský, V. (2010) · Measurement Science Review · doi:10.2478/v10048-010-0031-5 · Cited by 10
Cited by
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Taking your breath away: metabolomics breathes life in to personalized medicine
Rattray, N. J. W., Hamrang, Z., Trivedi, D. K., Goodacre, R., & Fowler, S. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.08.003 · Cited by 160
Hackner, K., & Pleil, J. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa5524 · Cited by 46
Metadata
- Authors
- Smith, D., Španěl, P., Herbig, J., & Beauchamp, J.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2014-03-28
- Volume
- 8
- Issue
- 2
- Pages
- 027101
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W1969139946
- Cited by
- 174
- References
- 141
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.