Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Breath analysis for the purpose of non-invasive diagnosis of lung cancer has yielded numerous candidate compounds with still questionable clinical relevance. To arrive at suitable volatile organic compounds our approach combined the analysis of different sources: isolated tumor samples compared to healthy lung tissues, and exhaled breath from lung cancer patients and healthy controls. Candidate compounds were further compared to substances previously identified in the comparison of transformed and normal lung epithelial cell lines. For human studies, a breath sampling device was developed enabling automated and CO2-controlled collection of the end-tidal air. All samples were first preconcentrated on multibed sorption tubes and analyzed with gas chromatography mass spectrometry (GC-MS). Significantly (p < 0.05) higher concentrations in all three types of cancer samples studied were observed for ethanol and n-octane. Additional metabolites (inter alia 2-methylpentane, n-hexane) significantly released by lung cancer cells were observed at higher levels in cancer lung tissues and breath samples (compared to respective healthy controls) with statistical significance (p < 0.05) only in breath samples. The results obtained confirmed the cancer-related origin of volatile metabolites, e.g. ethanol and octane that were both detected at significantly (p < 0.05) elevated concentrations in all three kinds of cancer samples studied. This work is an important step towards identification of volatile breath markers of lung cancer through the demonstration of cancer-related origin of certain volatile metabolites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R., Ma, J., Zou, Z., & Jemal, A. (2014) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21208 · Cited by 11,499
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
Applied Regression Analysis and Other Multivariable Methods
Walker, E. (1989) · Technometrics · doi:10.1080/00401706.1989.10488486 · Cited by 8,538
Survival of Patients with Stage I Lung Cancer Detected on CT Screening
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa060476 · Cited by 1,706
Increased nitric oxide in exhaled air of asthmatic patients
Kharitonov, S. A., Yates, D., Robbins, R. A., Barnes, P. J., Logan-Sinclair, R., & Shinebourne, E. A. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90931-8 · Cited by 1,436 · cited 1×
“Exhaled breath analysis has great potential for noninvasive diagnosis [17–19] as exemplified by the urea test for detection of Helicobacter pylori infection [20, 21] or the nitric oxide test for asthma monitoring [22, 23].”
BackgroundBenefits and Harms of CT Screening for Lung Cancer: A Systematic Review
Bach, P. B., Mirkin, J. N., Oliver, T. K., Azzoli, C. G., Berry, D. A., Brawley, O. W., Byers, T., Colditz, G. A., Gould, M. K., Jett, J. R., et al. (2012) · JAMA · doi:10.1001/jama.2012.5521 · Cited by 1,244 · cited 1×
“Though both imaging techniques have impressive sensitivity, which translates into a reduction in lung cancer deaths in the screened population [12–14], they also lead to the detection of many benign lung nodules and false positive results [15].”
BackgroundIncreased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232 · cited 1×
“Exhaled breath analysis has great potential for noninvasive diagnosis [17–19] as exemplified by the urea test for detection of Helicobacter pylori infection [20, 21] or the nitric oxide test for asthma monitoring [22, 23].”
BackgroundEstablishing the Diagnosis of Lung Cancer
Rivera, M. P., Mehta, A. C., & Wahidi, M. M. (2013) · Chest · doi:10.1378/chest.12-2353 · Cited by 1,089
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042 · cited 4×
“In our research approach we combine the comparative breath analysis of LC patients and normal subjects [37], ex vivo experiments with human lung tissues, in vitro experiments with normal and transformed cells as well as microorganisms frequently causing lung infections [38–40].”
BackgroundMethodInfluentialSelf-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953 · cited 3×
“Similarly, 4-methyloctane has been reported to be cancerassociated by Phillips et al [25] and Hakim et al [34].”
BackgroundSelf-citationSmith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898 · cited 1×
“Furthermore, CT and PET techniques are expensive and require experienced operating personnel, and additional concerns about radiation exposure associated with frequent CT imaging persist [16].”
BackgroundThe New Lung Cancer Staging System
Detterbeck, F. C., Boffa, D. J., & Tanoue, L. T. (2009) · Chest · doi:10.1378/chest.08-0978 · Cited by 817 · cited 1×
“Although benign tumors can be cured by surgical resection [2], tumor size, type, location and associated co-morbidities predispose only 20– 30% of patients suffering from lung cancer to such treatment [3, 4].”
BackgroundDi Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., D'Arcangelo, G., Roscioni, C., Finazzi-Agrò, A., & D'Amico, A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00086-1 · Cited by 663
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationNoninvasive Staging of Non-small Cell Lung Cancer
Silvestri, G. A., Gould, M. K., Margolis, M. L., Tanoue, L. T., McCrory, D., Toloza, E., & Detterbeck, F. (2007) · Chest · doi:10.1378/chest.07-1360 · Cited by 622
Detection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Machado, R. F., Laskowski, D., Deffenderfer, O., Burch, T., Zheng, S., Mazzone, P. J., Mekhail, T., Jennings, C., Stoller, J. K., Pyle, J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1184oc · Cited by 602
Patz, E. F., Goodman, P. C., & Bepler, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011303432208 · Cited by 599
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597 · cited 2×
“Furthermore, a link between 2-methylpentane and LC has already been shown [30, 31] who reported significantly higher concentration of this compound in the breath of NSCLC patients (compared to healthy controls).”
BackgroundSelf-citationDetection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Ullrich, F., & Grosch, W. (1987) · Zeitschrift f�r Lebensmittel-Untersuchung und -Forschung · doi:10.1007/bf01027663 · Cited by 555
Breath gas aldehydes as biomarkers of lung cancer
Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W. (2010) · International Journal of Cancer · doi:10.1002/ijc.24970 · Cited by 513 · cited 1×
“Although some authors have reported aldehydes containing 4 carbon atoms for LC [73], our study could not support this observation.”
ResultPoli, D., Carbognani, P., Corradi, M., Goldoni, M., Acampa, O., Balbi, B., Bianchi, L., Rusca, M., & Mutti, A. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-71 · Cited by 415
Detterbeck, F. C., Mazzone, P. J., Naidich, D. P., & Bach, P. B. (2013) · Chest · doi:10.1378/chest.12-2350 · Cited by 411
Infante, M., Cavuto, S., Lutman, F. R., Brambilla, G., Chiesa, G., Ceresoli, G., Passera, E., Angeli, E., Chiarenza, M., Aranzulla, G., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200901-0076oc · Cited by 379
The potential of the hydrocarbon breath test as a measure of lipid peroxidation
Frank Kneepkens, C. M., Lepage, G., & Roy, C. C. (1994) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)90110-4 · Cited by 369 · cited 1×
“The origin of many exhaled compounds is still debated: methylated alkanes, for example, are considered by some researchers as the secondary products of oxidative stress [74] whereas others disagree with this hypothesis [75, 76].”
BackgroundCurrent status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
A review of the emission of VOCs from polymeric materials used in buildings
Yu, C., & Crump, D. (1998) · Building and Environment · doi:10.1016/s0360-1323(97)00055-3 · Cited by 352
Uhde, E., & Salthammer, T. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.082 · Cited by 347
Prediction of lung cancer using volatile biomarkers in breath1
Phillips, M., Altorki, N., Austin, J. H. M., Cameron, R. B., Cataneo, R. N., Greenberg, J., Kloss, R., Maxfield, R. A., Munawar, M. I., Pass, H. I., et al. (2007) · Cancer Biomarkers · doi:10.3233/cbm-2007-3204 · Cited by 323
Volatile Markers of Breast Cancer in the Breath
Phillips, M., Cataneo, R. N., Ditkoff, B. A., Fisher, P., Greenberg, J., Gunawardena, R., Kwon, C. S., Rahbari-Oskoui, F., & Wong, C. (2003) · The Breast Journal · doi:10.1046/j.1524-4741.2003.09309.x · Cited by 289 · cited 1×
“n-nonane has previously been linked to breast cancer [26] and 2,3-butanedione to LC [30].”
BackgroundLung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Self-citationGohagan, J., Marcus, P., Fagerstrom, R., Pinsky, P., Kramer, B., & Prorok, P. (2004) · Chest · doi:10.1378/chest.126.1.114 · Cited by 279
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Self-citationThe 7th lung cancer TNM classification and staging system: Review of the changes and implications
Mirsadraee, S. (2012) · World Journal of Radiology · doi:10.4329/wjr.v4.i4.128 · Cited by 261 · cited 3×
“tissue was formalin fixed and paraffin embedded for diagnostic hematoxylin/eosin (H&E) staining and immunohistochemical evaluation according to an established classification scheme [45].”
BackgroundMethodInfluentialFilipiak, W., Sponring, A., Baur, M. M., Filipiak, A., Ager, C., Wiesenhofer, H., Nagl, M., Troppmair, J., & Amann, A. (2012) · BMC Microbiology · doi:10.1186/1471-2180-12-113 · Cited by 252
Self-citationKischkel, S., Miekisch, W., Sawacki, A., Straker, E. M., Trefz, P., Amann, A., & Schubert, J. K. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.06.005 · Cited by 227
Self-citationLittle, A. G., Gay, E. G., Gaspar, L. E., & Stewart, A. K. (2007) · Lung Cancer · doi:10.1016/j.lungcan.2007.03.012 · Cited by 227 · cited 1×
“An extensive study confirmed that most patients with stage III or IV lung cancer at the time of diagnosis time did not undergo surgery but instead were more likely to receive radiation treatment or even no treatment [5].”
BackgroundIson, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
TD-GC-MS Analysis of Volatile Metabolites of Human Lung Cancer and Normal Cells In vitro
Filipiak, W., Sponring, A., Filipiak, A., Ager, C., Schubert, J., Miekisch, W., Amann, A., & Troppmair, J. (2010) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-09-0162 · Cited by 223
Self-citationFilipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218 · cited 2×
“Importantly, none of the VOCs significant for lung tissues was found to be smoking-related in our previous detailed study [57].”
BackgroundSelf-citationRelease of volatile organic compounds (VOCs) from the lung cancer cell line CALU-1 in vitro
Filipiak, W., Sponring, A., Mikoviny, T., Ager, C., Schubert, J., Miekisch, W., Amann, A., & Troppmair, J. (2008) · Cancer Cell International · doi:10.1186/1475-2867-8-17 · Cited by 201 · cited 4×
“CALU-1 LC cells [42], but also recently reported to be a cancer-related VOC [34], was detected in this study at higher levels in tumor lung tissues (p = 0.”
BackgroundResultInfluentialSelf-citationBreath Analysis: The Approach Towards Clinical Applications
Amann, A., Spanel, P., & Smith, D. (2007) · Mini-Reviews in Medicinal Chemistry · doi:10.2174/138955707779802606 · Cited by 198
Self-citationPhysiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
Self-citationBlood and breath levels of selected volatile organic compounds in healthy volunteers
Mochalski, P., King, J., Klieber, M., Unterkofler, K., Hinterhuber, H., Baumann, M., & Amann, A. (2013) · The Analyst · doi:10.1039/c3an36756h · Cited by 190
Self-citationKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
Self-citationImpact of sampling procedures on the results of breath analysis
Miekisch, W., Kischkel, S., Sawacki, A., Liebau, T., Mieth, M., & Schubert, J. K. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026007 · Cited by 174 · cited 1×
“Although several authors have demonstrated the importance of CO2-controlled sampling of end-tidal air [65–68], the unsolved issues were sample contamination with plasticderived substances (released from tubing) and sample loss due to condensation of exhaled breath when passing through a long and unheated plastic tube.”
BackgroundMochalski, P., Grabowska-Polanowska, B., Śliwka, I., & Amann, A. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.12.003 · Cited by 172 · cited 1×
“Two breath sampling techniques were compared: (i) use of a plastic straw for collection of mixed-expiratory air (into sampling bags, such as Tedlar R ©, Kynar R © or Flexfilm R © bags, the usability of which has been discussed in other studies [52–54]) and (ii) use of a custom-made apparatus for collection of end-tida…”
MethodSelf-citationRelease of volatile organic compounds from the lung cancer cell line NCI-H2087 in vitro.
Sponring, A., Filipiak, W., Mikoviny, T., Ager, C., Schubert, J. K., Miekisch, W., Amann, A., & Troppmair, J. (2009) · PubMed · Cited by 169
Self-citationEffects of ventilation on the collection of exhaled breath in humans
Cope, K. A., Watson, M. T., Foster, W. M., Sehnert, S. S., & Risby, T. H. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01034.2003 · Cited by 161
A nanomaterial-based breath test for short-term follow-up after lung tumor resection
Broza, Y. Y., Kremer, R., Tisch, U., Gevorkyan, A., Shiban, A., Best, L. A., & Haick, H. (2012) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2012.07.009 · Cited by 138 · cited 1×
“Nevertheless, our observations are in agreement with the results of a longitudinal study performed by others demonstrating that 2-methyl-1pentene may be related to LC [72].”
ResultEffect of oxygen on breath markers of oxidative stress
Phillips, M., Cataneo, R. N., Greenberg, J., Grodman, R., Gunawardena, R., & Naidu, A. (2003) · European Respiratory Journal · doi:10.1183/09031936.02.00053402 · Cited by 123
Filipiak, W., Sponring, A., Baur, M., Ager, C., Filipiak, A., Wiesenhofer, H., Nagl, M., Troppmair, J., & Amann, A. (2012) · Microbiology · doi:10.1099/mic.0.062687-0 · Cited by 107
Self-citationKing, J., Mochalski, P., Unterkofler, K., Teschl, G., Klieber, M., Stein, M., Amann, A., & Baumann, M. (2012) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2012.05.159 · Cited by 99
Self-citationMochalski, P., Sponring, A., King, J., Unterkofler, K., Troppmair, J., & Amann, A. (2013) · Cancer Cell International · doi:10.1186/1475-2867-13-72 · Cited by 99
Self-citationAnalysis of volatile organic compounds (VOCs) in the headspace of NCI-H1666 lung cancer cells
Sponring, A., Filipiak, W., Ager, C., Schubert, J., Miekisch, W., Amann, A., & Troppmair, J. (2011) · Cancer Biomarkers · doi:10.3233/cbm-2010-0182 · Cited by 94
Self-citationBlood and breath profiles of volatile organic compounds in patients with end-stage renal disease
Mochalski, P., King, J., Haas, M., Unterkofler, K., Amann, A., & Mayer, G. J. (2014) · BMC Nephrology · doi:10.1186/1471-2369-15-43 · Cited by 87 · cited 1×
“Importantly, since human blood contains a myriad of organic molecules which are not necessarily of metabolic origin [37, 62–64]”
BackgroundSelf-citationHaick, H., Amal, Ding, Liu, Tisch, Xu, Shi, Zhao, Chen, Sun, et al. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s32680 · Cited by 83 · cited 1×
“Importantly, ethanol has been reported at higher level in tumorous than healthy stomach tissue [70] and a link to liver cancer has been shown [71].”
Background3-Heptanone as a potential new marker for valproic acid therapy
Erhart, S., Amann, A., Haberlandt, E., Edlinger, G., Schmid, A., Filipiak, W., Schwarz, K., Mochalski, P., Rostasy, K. M., Karall, D., et al. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/1/016004 · Cited by 70 · cited 1×
“Importantly, since human blood contains a myriad of organic molecules which are not necessarily of metabolic origin [37, 62–64]”
BackgroundSelf-citationA novel visually CO2 controlled alveolar breath sampling technique
Birken, T., Schubert, J. K., Miekisch, W., & Nöldge‐Schomburg, G. (2006) · Technology and Health Care · doi:10.3233/thc-2006-14605 · Cited by 60
Prevention of water vapour adsorption by carbon molecular sieves in sampling humid gases
Gawryś, M., Fastyn, P., Gawłowski, J., Gierczak, T., & Niedzielski, J. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01250-x · Cited by 54 · cited 1×
“nitrogen, as proposed by others [46, 47].”
Improved pre-concentration and detection methods for volatile sulphur breath constituents
Mochalski, P., Grabowska-Polanowska, B., Śliwka, I., & Amann, A. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.05.010 · Cited by 50
Self-citationFilipiak, W., Filipiak, A., Ager, C., Wiesenhofer, H., & Amann, A. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027107 · Cited by 49
Self-citationAnalysis of exhaled breath for screening of lung cancer patients
Amann, A., Ligor, M., Ligor, T., Bajtarevic, A., Ager, C., Pienz, M., Denz, H. A., Fiegl, M., Hilbe, W., Weiß, W. W., et al. (2010) · memo - Magazine of European Medical Oncology · doi:10.1007/s12254-010-0219-2 · Cited by 44 · cited 1×
“Particular effort has been made to develop breath analysis for the diagnosis of LC [24–32].”
BackgroundSelf-citationFilipiak, W., Sponring, A., Filipiak, A., Baur, M., Ager, C., Wiesenhofer, H., Margesin, R., Nagl, M., Troppmair, J., & Amann, A. (2013) · Elsevier eBooks · doi:10.1016/b978-0-44-462613-4.00023-4 · Cited by 43
Self-citationCURRENT STATUS OF CLINICAL BREATH ANALYSIS
Risby, T. H. (2005) · doi:10.1142/9789812701954_0017 · Cited by 35
Public policy and private provisions: changes in residential care from 1991 to 2001
Haynes, P., Banks, L., Balloch, S., & Hill, M. (2006) · Health & Social Care in the Community · doi:10.1111/j.1365-2524.2006.00638.x · Cited by 27
Infrared spectrometry based 13C‐octanoic acid breath test in measuring human solid gastric emptying
CHEN, C., CHEN, C., Lu, C., Chang, F., LEE, S., Chu, L.-S., Liu, R.-S., & Wu, H. (2002) · Journal of Gastroenterology and Hepatology · doi:10.1046/j.1440-1746.2003.02901.x · Cited by 24 · cited 1×
“Exhaled breath analysis has great potential for noninvasive diagnosis [17–19] as exemplified by the urea test for detection of Helicobacter pylori infection [20, 21] or the nitric oxide test for asthma monitoring [22, 23].”
BackgroundBREATH ETHANE IN DISEASE: METHODS FOR ANALYSIS BASED ON ROOM AIR CORRECTION
Cope, K. A. (2005) · doi:10.1142/9789812701954_0016 · Cited by 2
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationRecent advances in biosensor for detection of lung cancer biomarkers
Yang, G., Xiao, Z., Tang, C., Deng, Y., Huang, H., & He, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111416 · Cited by 330
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationExhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Metadata
- Authors
- Filipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., Jamnig, H., Troppmair, J., & Amann, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2014-05-27
- Volume
- 8
- Issue
- 2
- Pages
- 027111
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2153001247
- Cited by
- 173
- References
- 68
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.