Biochip-based study of unidirectional mitochondrial transfer from stem cells to myocytes via tunneling nanotubes
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Tunneling nanotubes (TNTs) are small membranous tubes of 50-1000 nm diameter observed to connect cells in culture. Transfer of subcellular organelles through TNTs was observed in vitro and in vivo, but the formation and significance of these structures is not well understood. A polydimethylsiloxane biochip-based coculture model was devised to constrain TNT orientation and explore both TNT-formation and TNT-mediated mitochondrial transfer. Two parallel microfluidic channels connected by an array of smaller microchannels enabled localization of stem cell and cardiomyocyte populations while allowing connections to form between them. Stem cells and cardiomyocytes were deposited in their respective microfluidic channels, and stem cell-cardiomyocyte pairs were formed via the microchannels. Formation of TNTs and transfer of stained mitochondria through TNTs was observed by 24 h real-time video recording. The data show that stem cells are 7.7 times more likely to initiate contact by initial extension of filopodia. By 24 h, 67% of nanotube connections through the microchannels are composed of cardiomyocyte membrane. Filopodial extension and retraction by stem cells draws an extension of TNTs from cardiomyocytes. MitoTracker staining shows that unidirectional transfer of mitochondria between stem cell-cardiomyocyte pairs invariably originates from stem cells. Control experiments with cardiac fibroblasts and cardiomyocytes show little nanotube formation between homotypic or mixed cell pairs and no mitochondrial transfer. These data identify a novel biological process, unidirectional mitochondrial transfer, mediated by heterotypic TNT connections. This suggests that the enhancement of cardiomyocyte function seen after stem-cell injection may be due to a bioenergetic stimulus provided by mitochondrial transfer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotubular Highways for Intercellular Organelle Transport
Rustom, A., Saffrich, R., Markovic, I., Walther, P., & Gerdes, H.-H. (2004) · Science · doi:10.1126/science.1093133 · Cited by 2,038
Islam, M. N., Das, S. R., Emin, M. T., Wei, M., Sun, L., Westphalen, K., Rowlands, D. J., Quadri, S. K., Bhattacharya, S., & Bhattacharya, J. (2012) · Nature Medicine · doi:10.1038/nm.2736 · Cited by 1,585
Sowinski, S., Jolly, C., Berninghausen, O., Purbhoo, M. A., Chauveau, A., Köhler, K., Oddos, S., Eissmann, P., Brodsky, F. M., Hopkins, C., et al. (2008) · Nature Cell Biology · doi:10.1038/ncb1682 · Cited by 754
Ahmad, T., Mukherjee, S., Pattnaik, B., Kumar, M., Singh, S., Kumar, M., Rehman, R., Tiwari, B. K., Jha, K. A., Barhanpurkar, A. P., et al. (2014) · The EMBO Journal · doi:10.1002/embj.201386030 · Cited by 542
Wiring through tunneling nanotubes--from electrical signals to organelle transfer
Abounit, S., & Zurzolo, C. (2012) · Journal of Cell Science · doi:10.1242/jcs.083279 · Cited by 386
Tunneling nanotubes: A new route for the exchange of components between animal cells
Gerdes, H.-H., Bukoreshtliev, N. V., & Barroso, J. F. V. (2007) · FEBS Letters · doi:10.1016/j.febslet.2007.03.071 · Cited by 304
Cited by
The power and potential of mitochondria transfer
Borcherding, N., & Brestoff, J. R. (2023) · Nature · doi:10.1038/s41586-023-06537-z · Cited by 514
Cell-cell communication: New insights and clinical implications
Su, J., Song, Y., Zhu, Z., Huang, X., Fan, J., Qiao, J., & Mao, F. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01888-z · Cited by 433
Intercellular mitochondrial transfer as a means of tissue revitalization
Liu, D., Gao, Y., Liu, J., Huang, Y., Yin, J., Feng, Y., Shi, L., Meloni, B. P., Zhang, C., Zheng, M., et al. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-020-00440-z · Cited by 403
Inter and Intracellular mitochondrial trafficking in health and disease
Shanmughapriya, S., Langford, D., & Natarajaseenivasan, K. (2020) · Ageing Research Reviews · doi:10.1016/j.arr.2020.101128 · Cited by 171
Artificial Mitochondria Transfer: Current Challenges, Advances, and Future Applications
Caicedo, A., Aponte, P. M., Cabrera, F., Hidalgo, C., & Khoury, M. (2017) · Stem Cells International · doi:10.1155/2017/7610414 · Cited by 150
“produce TNTs and deliver cargo to recipient cells [68].”
Background
Metadata
- Authors
- Yang, H., Borg, T. K., Ma, Z., Xu, M., Wetzel, G., Saraf, L. V., Markwald, R., Runyan, R. B., & Gao, B. Z.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2016-02-04
- Volume
- 8
- Issue
- 1
- Pages
- 015012
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2443279344
- Cited by
- 60
- References
- 6
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biochip-based study of unidirectional mitochondrial transfer from stem cells to myocytes via tunneling nanotubes. https://app.cochat.ai/papers/10.1088/1758-5090/8/1/015012
- The paper
- Yang, H., Borg, T. K., Ma, Z., Xu, M., Wetzel, G., Saraf, L. V., Markwald, R., Runyan, R. B., & Gao, B. Z. (2016). Biochip-based study of unidirectional mitochondrial transfer from stem cells to myocytes via tunneling nanotubes. Biofabrication. https://doi.org/10.1088/1758-5090/8/1/015012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.