CoChat

INSTRUMENT PERFORMANCE IN KEPLER 's FIRST MONTHS

Open access
Caldwell, Douglas A., Kolodziejczak, Jeffery J., Van Cleve, Jeffrey E., Jenkins, Jon M., Gazis, Paul R., Argabright, Vic S., Bachtell, Eric E., Dunham, Edward W., Geary, John C., Gilliland, Ronald L., Chandrasekaran, Hema, Li, Jie, Tenenbaum, Peter, Wu, Hayley, Borucki, William J., Bryson, Stephen T., Dotson, Jessie L., Haas, Michael R., Koch, David G. · 2010 · The Astrophysical Journal
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The Kepler Mission relies on precise differential photometry to detect the 80 parts per million (ppm) signal from an Earth–Sun equivalent transit. Such precision requires superb instrument stability on timescales up to ∼2 days and systematic error removal to better than 20 ppm. To this end, the spacecraft and photometer underwent 67 days of commissioning, which included several data sets taken to characterize the photometer performance. Because Kepler has no shutter, we took a series of dark images prior to the dust cover ejection, from which we measured the bias levels, dark current, and read noise. These basic detector properties are essentially unchanged from ground-based tests, indicating that the photometer is working as expected. Several image artifacts have proven more complex than when observed during ground testing, as a result of their interactions with starlight and the greater thermal stability in flight, which causes the temperature-dependent artifact variations to be on the timescales of transits. Because of Kepler 's unprecedented sensitivity and stability, we have also seen several unexpected systematics that affect photometric precision. We are using the first 43 days of science data to characterize these effects and to develop detection and mitigation methods that will be implemented in the calibration pipeline. Based on early testing, we expect to attain Kepler 's planned photometric precision over 80%–90% of the field of view.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/2041-8205/713/2/l92

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Caldwell, D. A., Kolodziejczak, J. J., Van Cleve, J. E., Jenkins, J. M., Gazis, P. R., Argabright, V. S., Bachtell, E. E., Dunham, E. W., Geary, J. C., Gilliland, R. L., Chandrasekaran, H., Li, J., Tenenbaum, P., Wu, H., Borucki, W. J., Bryson, S. T., Dotson, J. L., Haas, M. R., & Koch, D. G.
Venue
The Astrophysical Journal
Published
2010-03-30
Volume
713
Issue
2
Pages
L92-L96
ISSN
  • 2041-8205 (ISSN-L)
  • 2041-8213
OpenAlex
W2056752681
Cited by
167
References
1
FWCI
19.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.