CONSTRAINING CHANGES IN THE PROTON-ELECTRON MASS RATIO WITH INVERSION AND ROTATIONAL LINES
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report deep Green Bank Telescope spectroscopy in the redshifted NH 3 (1,1), CS 1–0, and H 2 CO 0 00 –1 01 lines from the z ∼ 0.685 absorber toward B0218+357. The inversion (NH 3 ) and rotational (CS, H 2 CO) line frequencies have different dependences on the proton–electron mass ratio μ, implying that a comparison between the line redshifts is sensitive to changes in μ. A joint three-component fit to the NH 3 , CS, and H 2 CO lines yields [Δμ/μ] = (−3.5 ± 1.2) × 10 −7 , from z ∼ 0.685 to today, where the error includes systematic effects from comparing lines from different species and possible frequency-dependent source morphology. Two additional sources of systematic error remain, due to time variability in the source morphology and velocity offsets between nitrogen-bearing and carbon-bearing species. We find no statistically significant (⩾3σ) evidence for changes in μ and obtain the stringent 3σ constraint, [Δμ/μ] < 3.6 × 10 −7 , over 6.2 Gyr; this is the best present limit on temporal changes in μ from any technique, and for any look-back time, by a factor ≳5.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 1×
“For linear variation, the present result yields µ̇/µ < 5.6 × 10−17 per year, more than an order of magnitude better than the best (model-dependent) laboratory constraint on changes inµ (Rosenband et al. 2008).”
BackgroundInfluentialFurther evidence for a variable fine-structure constant from Keck/HIRES QSO absorption spectra
Murphy, M. T., Webb, J. K., & Flambaum, V. V. (2003) · Monthly Notices of the Royal Astronomical Society · doi:10.1046/j.1365-8711.2003.06970.x · Cited by 514
Constraining Variationsin the Fine-Structure Constant, Quark Massesand the Strong Interaction
Murphy, M. T., Flambaum, V. V., Webb, J. K., Dzuba, V. V., Prochaska, J. X., & Wolfe, A. M. (2004) · Lecture Notes in Physics · doi:10.1007/978-3-540-40991-5_9 · Cited by 116 · cited 1×
“Indeed, one of these techniques, the many-multiplet method, has yielded evidence for changes inα: Murphy et al. (2004) obtained[∆α/α] = (−5.4 ± 1.2) × 10−6 from 143 absorbers with〈z〉 = 1.75 (see also Murphy et al. 2003).”
InfluentialGriest, K., Whitmore, J. B., Wolfe, A. M., Prochaska, J. X., Howk, J. C., & Marcy, G. W. (2010) · The Astrophysical Journal · doi:10.1088/0004-637x/708/1/158 · Cited by 94 · cited 1×
“This result has as yet been neither confirmed nor ruled out (e.g. Srianand et al. 2007; Molaro et al. 2008; Murphy et al. 2008b; Kanekar et al. 2010b), but evidence has now been found for additional systematic effects in the data, due to errors in the wavelength calibration (Griest et al. 2010).”
Result
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
The status of varying constants: a review of the physics, searches and implications
Martins, C. J. A. P. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa860e · Cited by 179
Molecules at z= 0.89: A 4-mm-rest-frame absorption-line survey toward PKS 1830−211⋆⋆⋆
Muller, S., Beelen, A., Guélin, M., Aalto, S., Black, J. H., Combes, F., Curran, S. J., Theule, P., & Longmore, S. N. (2011) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201117096 · Cited by 169
“…0218+357 and PKS 1830−211 (the only two known high-z ammonia absorbers) and yields no significant evidence of changes in µ, with constraints on ∆µ µ down to a few 10 −7 (Murphy et al. 2008; Henkel et al. 2009; Kanekar 2011), corresponding to a velocity offset of the order of a few tenths of kms−1.”
BackgroundInfluentialRahmani, H., Wendt, M., Srianand, R., Noterdaeme, P., Petitjean, P., Molaro, P., Whitmore, J. B., Murphy, M. T., Centurion, M., Fathivavsari, H., et al. (2013) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stt1356 · Cited by 108
Stability of fundamental couplings: A global analysis
Martins, C. J. A. P., & Pinho, A. M. M. (2017) · Physical Review D · doi:10.1103/physrevd.95.023008 · Cited by 32
Fundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Consistency tests of the stability of fundamental couplings and unification scenarios
Ferreira, M. C., Frigola, O., Martins, C. J. A. P., Monteiro, A. M. R. V. L., & Solà, J. (2014) · Physical Review D · doi:10.1103/physrevd.89.083011 · Cited by 29
A sub-ppm upper limit on the cosmological variations of the fine structure constant α
Muller, S., Beelen, A., Guélin, M., Black, J. H., Combes, F., Bethlem, H. L., Gérin, M., Henkel, C., Menten, K. M., Murphy, M. T., et al. (2026) · Astronomy & Astrophysics · doi:10.1051/0004-6361/202557492 · Cited by 3
Metadata
- Authors
- Kanekar, N.
- Venue
- The Astrophysical Journal
- Publisher
- American Astronomical Society
- Published
- 2011-01-19
- Volume
- 728
- Issue
- 1
- Pages
- L12
- ISSN
- 2041-8205 (ISSN-L)
- 2041-8213
- OpenAlex
- W2000438322
- Cited by
- 103
- References
- 4
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.