Miniaturized Nebulization Catheters: A New Approach for Delivery of Defined Aerosol Doses to the Rat Lung
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A nebulization catheter technique (AeroProbe) was adapted and evaluated as a new approach for pulmonary delivery of defined aerosol doses to the rat lung. The lung distribution profile was evaluated by dosing Evans blue and Nile blue dye, respectively, to isolated and perfused rat lungs (IPL) and to the lungs of anesthetized and tracheal-intubated rats. The intratracheal aerosol dosing was synchronized with the inspiration of the lungs. Immediately after dosing, the lungs were dissected into upper- and lower trachea, bronchi, and parenchyma. The dye was then extracted from the tissue samples to determine the regional distribution and the recovery of the aerosol dose in the lungs. The droplet-size distribution and the weight of the delivered aerosol dose were analyzed with laser diffraction and gravimetric analysis respectively. The recovery of the delivered dose was high, 99 +/- 12 and 105 +/- 1%, respectively, in the in vivo administrations and IPL-experiments. The lung distribution profile after aerosol dosing to anesthetized rats was mainly tracheobronchial. Only 12 +/- 4% of the dose was recovered in the lung parenchyma. However, after aerosol dosing to the IPL, 38 +/- 11% of the dose was distributed to the lung parenchyma. At the settings used, the nebulization catheter aerosolized 1-2 microL of liquid per puff using 1-1.5 mL of air. The droplet-size distribution of the generated aerosols was broad (2-8% <3 microm; 10% <4-7 microm; 50% <10-15 microm; and 90% <20-40 microm). The nebulization catheter technique provides a complement to existing methodology for pulmonary drug delivery in small animals. With this new technique, defined aerosol doses can be delivered into the lungs of rats with no need for aerosol dosimetry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The next step towards testing the toxicity of respirable aerosols is the direct insufflation method, where the study material is injected with an air puff directly into the endotracheally intubated lung, either as a liquid spray (Tronde et al., 2002) or as a suspended dry powder formulation (Bosquillon et al., 2004; Larsen and Regal, 2002).”
From Toxicity of lunar dust (2012) · cites this paper as Tronde et al., 2002
Citations
Cites
Impaired Leucocyte Functions in Diabetic Patients
Delamaire, M., Maugendre, D., Moreno, M., Le Goff, M.-C., Allannic, H., & Genetet, B. (1997) · Diabetic Medicine · doi:10.1002/(sici)1096-9136(199701)14:1<29::aid-dia300>3.0.co;2-v · Cited by 1,074
Mechanisms of macromolecule absorption by the lungs
Patton, J. S. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00113-l · Cited by 641
Allometric Relationships of Cell Numbers and Size in the Mammalian Lung
Stone, K. C., Mercer, R. R., Gehr, P., Stockstill, B., & Crapo, J. D. (1992) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb/6.2.235 · Cited by 550 · cited 1×
“15,36 The device was well adapted to handle small amounts of test formulation, which is an important aspect for pulmonary drug delivery investigations during early drug development.”
Pulmonary distribution of particles given by intratracheal instillation or by aerosol inhalation
Brain, J. D., Knudson, D. E., Sorokin, S. P., & Davis, M. A. (1976) · Environmental Research · doi:10.1016/0013-9351(76)90107-9 · Cited by 416 · cited 2×
“10,11 To obtain reliable dosing the liquid must be carefully in-stilled in order not to cause airway obstruction, disturb the normal breathing pattern of the animal, or induce cough, which will lead to rapid clearance of part of the dose from the airways into the mouth and stomach.”
Hlastala, M. P., & Berger, A. J. (2001) · doi:10.1093/oso/9780195138467.001.0001 · Cited by 276
Effects of various inhalation modes on the deposition of radioactive pressurized aerosols.
Newman, S. P., Pavia, D., GARLAND, N., & Clarke, S. W. (1982) · PubMed · Cited by 172
Tronde, A., Nordén, B. O., Marchner, H., Wendel, A., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10386 · Cited by 158
Clark, A. R. (1995) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(94)00255-4 · Cited by 145 · cited 1×
“20 The setup corresponded to a proposed methodology for droplet-size determination from nebulizers using laser diffraction instruments.”
The pulmonary consequences of a deep breath
Nicholas, T. E., Power, J. H. T., & Barr, H. A. (1982) · Respiration Physiology · doi:10.1016/0034-5687(82)90119-0 · Cited by 137
Inhalation Delivery of Therapeutic Peptides and Proteins
Adjei, A. L., & Gupta, P. (1997) · doi:10.1201/9781420001242 · Cited by 136
Research works printed but not linked: 9
- 10.1002/(SICI)1096-9136(199701)14:1<63::AID-DIA298>3.3.CO;2-6 · doi:10.1002/(sici)1096-9136(199701)14:1<63::aid-dia298>3.3.co;2-6
- Brown R.A., 1983, Drug Metab. Dispos., 11, 355
- Widdicombe J., 1998, Indian J. Physiol. Pharmacol., 42, 3
- Schanker L.S., 1986, Drug Metab. Dispos., 14, 79
- Taljanski W., 1997, Drug Metab. Dispos., 25, 917
- MacIntyre N.R., 2001, Respir. Care, 46, 193
- Wixson S.K., 1987, Lab. Anim. Sci., 37, 736
- Newman S.P., 1982, Eur. J. Respir. Dis., 63, 57
- 10.1002/(SICI)1099-1263(199803/04)18:2<149::AID-JAT490>3.3.CO;2-C · doi:10.1002/(sici)1099-1263(199803/04)18:2<149::aid-jat490>3.3.co;2-c
Cited by
Sakagami, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.012 · Cited by 331
“〈LIQUID〉 Tracheotomy SYR-N 250 μl 75 ∼ 10 ARG 100 μl 55 ∼ 10 ARG 10 μl 25 ∼ 30 ARG Tracheotomy SYR 100 μl 67 15 [77] Tracheotomy CM-SPR 100 μl 91 5 [31] 20 μl 73 18 [32] Orotracheal SYR-N 100 μl 85 ∼ 4 ARG 10 μl 50 ∼ 18 ARG Orotracheal SYR-N 100 μl 92 ∼ 15 [73] Orotracheal CM-SPR 250 μl 62 NR [68] Orotracheal CM-SPR ∼…”
BackgroundMethodResultInfluentialFröhlich, E., & Salar-Behzadi, S. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15034795 · Cited by 249
“When coupled to a ventilator, a nebulization catheter can deliver a pulse-timed spray dosing delivery to the lung [95].”
MethodAerosol Delivery During Mechanical Ventilation: From Basic Techniques to New Devices
Dhand, R. (2008) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2007.0663 · Cited by 164
“The intracorporeal nebulizing catheter (Aeroprobe; Trudell Medical International, London, ON, Canada) is a novel device that produces an aerosol in the trachea.(64) A central lumen transmits the solution to be nebulized and compressed gas is forced under high pressure (100 psi) at a variable flow rate (0.”
Tronde, A., Nordén, B. O., Marchner, H., Wendel, A., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10386 · Cited by 158
Ehrhardt, C., & Kim, K. (2007) · Springer eBooks · doi:10.1007/978-0-387-74901-3 · Cited by 183
Tronde, A., Nordén, B., Jeppsson, A.-B., Brunmark, P., Nilsson†, E., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Drug Targeting · doi:10.1080/1061186031000086117 · Cited by 104
“‡ From Tronde et al. 2002b; concentration in donor compartment 5mM. { Significantly different from A-B, ðp , 0:05Þ: (percentage molecular polar surface area of the total molecular surface area) ðr ¼ 20:79Þ (Fig.”
BackgroundMethodInfluentialLaser Diffractometry as a Technique for the Rapid Assessment of Aerosol Particle Size from Inhalers
Mitchell, J. P., NAGEL, M. W., Nichols, S., & Nerbrink, O. (2006) · Journal of Aerosol Medicine · doi:10.1089/jam.2006.19.409 · Cited by 103
Linnarsson, D., Carpenter, J., Fubini, B., Gerde, P., Karlsson, L. L., Loftus, D. J., Prisk, G. K., Staufer, U., Tranfield, E. M., & van Westrenen, W. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.05.023 · Cited by 95
Aerosolized Antibiotics for Ventilator-associated Pneumonia: Lessons from Experimental Studies
Rouby, J., Bouhemad, B., Monsel, A., Brisson, H., Arbelot, C., & Lü, Q. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182755d7a · Cited by 101
Selo, M. A., Sake, J. A., Kim, K., & Ehrhardt, C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113862 · Cited by 84
Nanotherapeutics for pulmonary drug delivery: An emerging approach to overcome respiratory diseases
Kole, E. B., Jadhav, K., Shirsath, N. R., Dudhe, P. B., Verma, R. K., Chatterjee, A., & Naik, J. (2023) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2023.104261 · Cited by 85
How Should Aerosols Be Delivered During Invasive Mechanical Ventilation?
Dhand, R. (2017) · Respiratory Care · doi:10.4187/respcare.05803 · Cited by 84
Pulmonary Targeting with Biodegradable Salbutamol-Loaded Nanoparticles
Beck‐Broichsitter, M., Gauss, J., Gessler, T., Seeger, W., Kissel, T., & Schmehl, T. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0759 · Cited by 72
“Tronde et al. (30) have used a similar method, an intratracheal nebulization catheter technique synchronized with inspiration, for the delivery of aerosols to small rodents and isolated rat lungs.”
Modifying and Integrating in vitro and ex vivo Respiratory Models for Inhalation Drug Screening
Cidem, A., Bradbury, P., Traini, D., & Ong, H. X. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.581995 · Cited by 70
“ALI culture systems have been heavily reviewed in the literature and have delivered highly impactful research outcomes (Movia et al., 2018; Upadhyay and Palmberg, 2018) however, the use of in vitro ALI models to determine toxicity, delivery and efficacy of inhaled therapeutics requires greater…”
BackgroundEriksson, J., Sjögren, E., Thörn, H. A., Rubin, K., Bäckman, P., & Lennernäs, H. (2017) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2017.11.013 · Cited by 51
“) was taken from the literature; the ratio between the alveolar and tracheobronchial regions was 2:3 [27].”
Aerosol Delivery of siRNA to the Lungs. Part 1: Rationale for Gene Delivery Systems
Youngren-Ortiz, S. R., Gandhi, N. S., España‐Serrano, L., & Chougule, M. B. (2015) · KONA Powder and Particle Journal · doi:10.14356/kona.2016014 · Cited by 51
Generation of liposome aerosols with the Aeroneb Pro and the AeroProbe nebulizers
Gaspar, M. M., Gobbo, O. L., & Ehrhardt, C. (2010) · Journal of Liposome Research · doi:10.3109/08982100903085150 · Cited by 46
Optimized aerosol delivery to a mechanically ventilated rodent
MacLoughlin, R. J., Higgins, B. D., Laffey, J. G., & O'Brien, T. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0717 · Cited by 45
“0015 mg mL (1)).((19)) The Evans blue standards were made up in homogenate supernatant isolated from untreated control lungs.”
Effective inhaled drug administration to mechanically ventilated patients
Dhand, R., & Mercier, E. (2006) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.3.6.47 · Cited by 42
Selg, E., Ewing, P., Acevedo, F., Sjöberg, C.-O., Ryrfeldt, Å., & Gerde, P. (2012) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2012.0971 · Cited by 42
Ewing, P., Blomgren, B., Ryrfeldt, Å., & Gerde, P. (2006) · Toxicological Sciences · doi:10.1093/toxsci/kfj104 · Cited by 47
“The studied agents including BaP have been added either via the circulation, by intratracheal instillation (Bond et al., 1988), or as nebulized suspensions (Tronde et al., 2002).”
Insights on animal models to investigate inhalation therapy: Relevance for biotherapeutics
Guillon, A., Sécher, T., Dailey, L. A., Vecellio, L., Monte, M. D., Si‐Tahar, M., Diot, P., Page, C. P., & Heuzé‐Vourc'h, N. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.11.049 · Cited by 43
“A nebulization catheter device (AeroProbe TM , Trudell Medical International, Canada) was also commercialized to administer aerosols directly into the airways and to provide a complementary approach to existing methodologies for pulmonary drug delivery in small animals (Tronde et al., 2002).”
Selting, K. A., Waldrep, J. C., Reinero, C. R., Branson, K., Gustafson, D. L., Kim, D. Y., Henry, C. J., Owen, N. K., Madsen, R., & Dhand, R. (2008) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0684 · Cited by 39
A miniaturized nebulization catheter for improved gene delivery to the mouse lung
Köping‐Höggård, M., Issa, M. M., Köhler, T., Tronde, A., Vårum, K. M., & Artursson, P. (2005) · The Journal of Gene Medicine · doi:10.1002/jgm.762 · Cited by 37
“, Malvern, UK) was used to measure the droplet size from the NCD as described previously [15].”
BackgroundMethodFreiwald, M., Valotis, A., Kirschbaum, A., McClellan, M., Mürdter, T. E., Fritz, P., Friedel, G., Thomas, M., & Högger, P. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-21 · Cited by 36
Beck‐Broichsitter, M., Schmehl, T., Seeger, W., & Gessler, T. (2010) · Journal of Nanomaterials · doi:10.1155/2011/163791 · Cited by 43
“In contrast, the aerosol delivery to IPL models can be easily controlled by adjustment of the ventilation regimen [142, 165].”
BackgroundMethodFioni, A., Selg, E., Cenacchi, V., Acevedo, F., Brogin, G., Gerde, P., & Puccini, P. (2017) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2017.1369 · Cited by 32
Zheng, Z., Wang, R.-S., Cheng, H.-Q., Duan, T., He, B., Tang, D., Gu, F., & Zhu, Q. (2010) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2010.09.034 · Cited by 29
The Isolated Perfused Lung for Drug Absorption Studies
Tronde, A., Bosquillon, C., & Forbes, B. (2007) · Springer eBooks · doi:10.1007/978-0-387-74901-3_6 · Cited by 32
“IPL experiments can be designed to address specific issues such as pharmacological effect [61], physiological phenomena [97], drug dissolution and absorption [96, 139], mechanisms of absorption [118], metabolism [28, 45, 78, 116, 138], tissue disposition [5, 82, 117] and retention [67, 117].”
BackgroundImproving Aerosol Drug Delivery During Invasive Mechanical Ventilation With Redesigned Components
Longest, P. W., Azimi, M., Golshahi, L., & Hindle, M. (2013) · Respiratory Care · doi:10.4187/respcare.02782 · Cited by 27
Palko, H. A., Fung, J. Y., & Louie, A. Y. (2010) · Inhalation Toxicology · doi:10.3109/08958371003713745 · Cited by 26
“Instillation also can be technically challenging and care must be taken to avoid disturbing the normal breathing pattern or else cough may be induced, which can rapidly clear part of the dose into the mouth and stomach (Tronde et al., 2002).”
BackgroundMethodTronde, A., Krondahl, E., von Euler-Chelpin, H., Brunmark, P., Bengtsson, U. H., Ekström, G., & Lennernäs, H. (2002) · Peptides · doi:10.1016/s0196-9781(01)00624-6 · Cited by 26
Nambiar, M. P., Wright, B. S., Rezk, P. E., Smith, K. B., Gordon, R. K., Moran, T. S., Richards, S. M., & Sciuto, A. M. (2006) · Toxicology Mechanisms and Methods · doi:10.1080/15376510600748760 · Cited by 23
“The method has been recently adapted by others to administer drugs to mice, rats, and infants (Tronde et al. 2002; Koping-Hoggard et al. 2005; von der et al. 2002b, 2002a; Krondahl et al. 2002; Fok et al. 1996).”
MethodAerosol Delivery During Mechanical Ventilation: From Basic Techniques to New Devices
Dhand, R. (2008) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0663 · Cited by 22
Krondahl, E., Tronde, A., Eirefelt, S., Forsmo-Bruce, H., Ekström, G., Bengtsson, U. H., & Lennernäs, H. (2002) · Peptides · doi:10.1016/s0196-9781(01)00629-5 · Cited by 16
Enright, H. A., Bratt, J. M., Bluhm, A. P., Kenyon, N. J., & Louie, A. Y. (2013) · Experimental Lung Research · doi:10.3109/01902148.2013.819048 · Cited by 13
“Instillation does not distribute as evenly as an inhalation technique and can often result in an inhomogeneous lung distribution [42, 43].”
BackgroundOral inhalation therapy: meeting the challenge of developing more patient-appropriate devices
Mitchell, J. P., & NAGEL, M. W. (2009) · Expert Review of Medical Devices · doi:10.1586/17434440.6.2.147 · Cited by 13
Aerosol delivery during mechanical ventilation.
HESS, D. R. (2002) · PubMed · Cited by 6
Ansari, Z., Battikha, J. P., Singh, C., & Perlman, C. E. (2024) · Physiological Reports · doi:10.14814/phy2.70018 · Cited by 2
“One approach is to homogenize tissue and extract and analyze a neb-ulized marker, for example spectrophotometric absorbance or luminescence of a dye (Hofstetter et al., 2004; Köping-Höggård et al., 2005; MacLoughlin et al., 2009; Tronde et al., 2002).”
BackgroundMethodMireskandari, K., Ardakani, Y. H., Moghadam, E. S., Ketabchi, F., & Rouini, M. R. (2022) · Current Drug Delivery · doi:10.2174/1567201819666220823161318 · Cited by 2
Vecellio, L., Majoral, C., Bonnemaison, E., Gagnadoux, F., Mercier, E., Chinet, T., Salmerón, S., & Diot, P. (2008) · Encyclopédie médico-chirurgicale. Pneumologie · doi:10.1016/s1155-195x(08)47938-0 · Cited by 1
Inhalation Therapy for Pulmonary Tuberculosis
Hirota, K., Tomoda, K., Makino, K., & Terada, H. (2014) · Advances in delivery science and technology · doi:10.1007/978-3-319-11355-5_5
“However, the aerosols delivered into the lungs were mainly trapped at tracheobronchial sites owing to large mass median diameter of the droplets, which was 11 μm [71].”
BackgroundLinear and Branched Chitosan Oligomers as Delivery Systems for pDNA and siRNA In Vitro and In Vivo
Issa, M. (2006) · Uppsala University Publications (Uppsala University) · Cited by 2
Development of lentiviral airway gene therapy aerosol delivery techniques for cystic fibrosis
Padmanabhan, H. (2019) · Adelaide Research & Scholarship (AR&S) (University of Adelaide)
Pharmacokinetic evaluation of inhaled formulations: from in vitro models to clinical assessment
Ren, C., Zhang, Y., Zhang, Y., Kong, Y., Chen, X., Du, G., & 韩光 (2026) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2026.127506
Metadata
- Authors
- Tronde, A., Baran, G., Eirefelt, S., Lennernäs, H., & Bengtsson, U. H.
- Affiliations
- Uppsala University (SE)
- Trudell Medical International (Canada) (CA)
- AstraZeneca (Sweden) (SE)
- Venue
- Journal of Aerosol Medicine
- Publisher
- SAGE Publications
- Published
- 2002-09
- Volume
- 15
- Issue
- 3
- Pages
- 283-296
- ISSN
- 0894-2684 (ISSN-L)
- 1557-9026
- OpenAlex
- W2162724031
- Cited by
- 45
- References
- 38
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 4 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
- Locations
- Journal of Aerosol Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- AstraZeneca
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- aerosol drug delivery, pulmonary drug delivery, regional lung distribution, isolated perfused lung, droplet size distribution, rat lung, aerosol dosimetry
- MeSH terms
- Administration, Inhalation, Aerosols, Animals, Catheterization, Coloring Agents, Lung, Male, Miniaturization, Nebulizers and Vaporizers, Perfusion, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.