CoChat

Miniaturized Nebulization Catheters: A New Approach for Delivery of Defined Aerosol Doses to the Rat Lung

Tronde, Ann, Baran, George, Eirefelt, Stefan, Lennernäs, Hans, Bengtsson, Ursula Hultkvist · 2002 · Journal of Aerosol Medicine

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

A nebulization catheter technique (AeroProbe) was adapted and evaluated as a new approach for pulmonary delivery of defined aerosol doses to the rat lung. The lung distribution profile was evaluated by dosing Evans blue and Nile blue dye, respectively, to isolated and perfused rat lungs (IPL) and to the lungs of anesthetized and tracheal-intubated rats. The intratracheal aerosol dosing was synchronized with the inspiration of the lungs. Immediately after dosing, the lungs were dissected into upper- and lower trachea, bronchi, and parenchyma. The dye was then extracted from the tissue samples to determine the regional distribution and the recovery of the aerosol dose in the lungs. The droplet-size distribution and the weight of the delivered aerosol dose were analyzed with laser diffraction and gravimetric analysis respectively. The recovery of the delivered dose was high, 99 +/- 12 and 105 +/- 1%, respectively, in the in vivo administrations and IPL-experiments. The lung distribution profile after aerosol dosing to anesthetized rats was mainly tracheobronchial. Only 12 +/- 4% of the dose was recovered in the lung parenchyma. However, after aerosol dosing to the IPL, 38 +/- 11% of the dose was distributed to the lung parenchyma. At the settings used, the nebulization catheter aerosolized 1-2 microL of liquid per puff using 1-1.5 mL of air. The droplet-size distribution of the generated aerosols was broad (2-8% <3 microm; 10% <4-7 microm; 50% <10-15 microm; and 90% <20-40 microm). The nebulization catheter technique provides a complement to existing methodology for pulmonary drug delivery in small animals. With this new technique, defined aerosol doses can be delivered into the lungs of rats with no need for aerosol dosimetry.

Overview

Integrity signals

Registry

Crossref · 10.1089/089426802760292627

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 9

  1. 10.1002/(SICI)1096-9136(199701)14:1<63::AID-DIA298>3.3.CO;2-6 · doi:10.1002/(sici)1096-9136(199701)14:1<63::aid-dia298>3.3.co;2-6
  2. Brown R.A., 1983, Drug Metab. Dispos., 11, 355
  3. Widdicombe J., 1998, Indian J. Physiol. Pharmacol., 42, 3
  4. Schanker L.S., 1986, Drug Metab. Dispos., 14, 79
  5. Taljanski W., 1997, Drug Metab. Dispos., 25, 917
  6. MacIntyre N.R., 2001, Respir. Care, 46, 193
  7. Wixson S.K., 1987, Lab. Anim. Sci., 37, 736
  8. Newman S.P., 1982, Eur. J. Respir. Dis., 63, 57
  9. 10.1002/(SICI)1099-1263(199803/04)18:2<149::AID-JAT490>3.3.CO;2-C · doi:10.1002/(sici)1099-1263(199803/04)18:2<149::aid-jat490>3.3.co;2-c

Cited by

See all 45

Metadata

Authors
Tronde, A., Baran, G., Eirefelt, S., Lennernäs, H., & Bengtsson, U. H.
Affiliations
  • Uppsala University (SE)
  • Trudell Medical International (Canada) (CA)
  • AstraZeneca (Sweden) (SE)
Venue
Journal of Aerosol Medicine
Published
2002-09
Volume
15
Issue
3
Pages
283-296
ISSN
  • 0894-2684 (ISSN-L)
  • 1557-9026
OpenAlex
W2162724031
Cited by
45
References
38
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 4 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 3
FWCI
1.91
Type
journal article
Language
en
Open access
closed
Licence
www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
Locations
  • Journal of Aerosol Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
AstraZeneca
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
Keywords
aerosol drug delivery, pulmonary drug delivery, regional lung distribution, isolated perfused lung, droplet size distribution, rat lung, aerosol dosimetry
MeSH terms
Administration, Inhalation, Aerosols, Animals, Catheterization, Coloring Agents, Lung, Male, Miniaturization, Nebulizers and Vaporizers, Perfusion, Rats, Sprague-Dawley, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.