Miniaturized Nebulization Catheters: A New Approach for Delivery of Defined Aerosol Doses to the Rat Lung
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
A nebulization catheter technique (AeroProbe) was adapted and evaluated as a new approach for pulmonary delivery of defined aerosol doses to the rat lung. The lung distribution profile was evaluated by dosing Evans blue and Nile blue dye, respectively, to isolated and perfused rat lungs (IPL) and to the lungs of anesthetized and tracheal-intubated rats. The intratracheal aerosol dosing was synchronized with the inspiration of the lungs. Immediately after dosing, the lungs were dissected into upper- and lower trachea, bronchi, and parenchyma. The dye was then extracted from the tissue samples to determine the regional distribution and the recovery of the aerosol dose in the lungs. The droplet-size distribution and the weight of the delivered aerosol dose were analyzed with laser diffraction and gravimetric analysis respectively. The recovery of the delivered dose was high, 99 +/- 12 and 105 +/- 1%, respectively, in the in vivo administrations and IPL-experiments. The lung distribution profile after aerosol dosing to anesthetized rats was mainly tracheobronchial. Only 12 +/- 4% of the dose was recovered in the lung parenchyma. However, after aerosol dosing to the IPL, 38 +/- 11% of the dose was distributed to the lung parenchyma. At the settings used, the nebulization catheter aerosolized 1-2 microL of liquid per puff using 1-1.5 mL of air. The droplet-size distribution of the generated aerosols was broad (2-8% <3 microm; 10% <4-7 microm; 50% <10-15 microm; and 90% <20-40 microm). The nebulization catheter technique provides a complement to existing methodology for pulmonary drug delivery in small animals. With this new technique, defined aerosol doses can be delivered into the lungs of rats with no need for aerosol dosimetry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The next step towards testing the toxicity of respirable aerosols is the direct insufflation method, where the study material is injected with an air puff directly into the endotracheally intubated lung, either as a liquid spray (Tronde et al., 2002) or as a suspended dry powder formulation (Bosquillon et al., 2004; Larsen and Regal, 2002).”
From Toxicity of lunar dust (2012) · cites this paper as Tronde et al., 2002
Citations
Cites
Impaired Leucocyte Functions in Diabetic Patients
Delamaire, M., Maugendre, D., Moreno, M., Le Goff, M.-C., Allannic, H., & Genetet, B. (1997) · Diabetic Medicine · doi:10.1002/(sici)1096-9136(199701)14:1<29::aid-dia300>3.0.co;2-v · Cited by 1,074
Mechanisms of macromolecule absorption by the lungs
Patton, J. S. (1996) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00113-l · Cited by 641
Allometric Relationships of Cell Numbers and Size in the Mammalian Lung
Stone, K. C., Mercer, R. R., Gehr, P., Stockstill, B., & Crapo, J. D. (1992) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb/6.2.235 · Cited by 550 · cited 1×
“15,36 The device was well adapted to handle small amounts of test formulation, which is an important aspect for pulmonary drug delivery investigations during early drug development.”
Pulmonary distribution of particles given by intratracheal instillation or by aerosol inhalation
Brain, J. D., Knudson, D. E., Sorokin, S. P., & Davis, M. A. (1976) · Environmental Research · doi:10.1016/0013-9351(76)90107-9 · Cited by 416 · cited 2×
“10,11 To obtain reliable dosing the liquid must be carefully in-stilled in order not to cause airway obstruction, disturb the normal breathing pattern of the animal, or induce cough, which will lead to rapid clearance of part of the dose from the airways into the mouth and stomach.”
Hlastala, M. P., & Berger, A. J. (2001) · doi:10.1093/oso/9780195138467.001.0001 · Cited by 276
Effects of various inhalation modes on the deposition of radioactive pressurized aerosols.
Newman, S. P., Pavia, D., GARLAND, N., & Clarke, S. W. (1982) · PubMed · Cited by 172
Tronde, A., Nordén, B. O., Marchner, H., Wendel, A., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10386 · Cited by 158
Clark, A. R. (1995) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(94)00255-4 · Cited by 145 · cited 1×
“20 The setup corresponded to a proposed methodology for droplet-size determination from nebulizers using laser diffraction instruments.”
The pulmonary consequences of a deep breath
Nicholas, T. E., Power, J. H. T., & Barr, H. A. (1982) · Respiration Physiology · doi:10.1016/0034-5687(82)90119-0 · Cited by 137
Inhalation Delivery of Therapeutic Peptides and Proteins
Adjei, A. L., & Gupta, P. (1997) · doi:10.1201/9781420001242 · Cited by 136
Colthorpe, P., Farr, S. J., Taylor, G., Smith, L. J., & Wyatt, D. J. (1992) · Pharmaceutical Research · doi:10.1023/a:1015851521551 · Cited by 124
Time-action Profile of Inhaled Insulin
Heinemann, L., Traut, T., & Heise, T. (1997) · Diabetic Medicine · doi:10.1002/(sici)1096-9136(199701)14:1<63::aid-dia298>3.0.co;2-f · Cited by 122
Absorption of aerosolized drugs from the rat lung.
Brown, R. A., & Schanker, L. S. (1983) · Drug Metabolism and Disposition · doi:10.1016/s0090-9556(25)08032-8 · Cited by 108 · cited 1×
“4–7 The respiratory anatomy, physiology, pathophysiology, the aerosol characteristics, and the inhalation device are parameters that affect the lung deposition profile of the administered drug.”
Wixson, S. K., White, W. J., Hughes, H. C., Lang, C., & Marshall, W. (1987) · PubMed · Cited by 104
Tronde, A., Nordén, B., Jeppsson, A.-B., Brunmark, P., Nilsson†, E., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Drug Targeting · doi:10.1080/1061186031000086117 · Cited by 104
Leong, B. K. J., Coombs, J. K., Sabaitis, C. P., Rop, D. A., & Aaron, C. S. (1998) · Journal of Applied Toxicology · doi:10.1002/(sici)1099-1263(199803/04)18:2<117::aid-jat486>3.0.co;2-d · Cited by 104
Leong, B. K. J., Coombs, J. K., Sabaitis, C. P., Rop, D. A., & Aaron, C. S. (1998) · Journal of Applied Toxicology · doi:10.1002/(sici)1099-1263(199803/04)18:2<149::aid-jat490>3.0.co;2-l · Cited by 104
Schanker, L. S., Mitchell, E. W., & Brown, R. A. (1986) · Drug Metabolism and Disposition · doi:10.1016/s0090-9556(25)08279-0 · Cited by 91 · cited 1×
“12,17 The use of a pulmonary delivery method that mimics the methods used in clinical therapy may therefore be important for preclinical investigations of pulmonary drug absorption.”
An improved setup for the isolated perfused rat lung
Uhlig, S., & Wollin, L. (1994) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/1056-8719(94)90047-7 · Cited by 87
Deposition and Fate of Aerosolized Drugs
Newhouse, M. T., & Ruffin, R. E. (1978) · CHEST Journal · doi:10.1378/chest.73.6_supplement.936 · Cited by 82 · cited 1×
“28,29 Accordingly, the breath frequency in the IPL-experiments was decreased from 80 to 30 breaths/min, resulting in a lower inhalation flow rate, to facilitate a peripheral lung deposition, whereas the breath frequency in the anesthetized and spontaneously breathing rats was about 80–100…”
Niven, R. W., Whitcomb, K. L., Shaner, L., Ip, A. Y., & Kinstler, O. B. (1995) · Pharmaceutical Research · doi:10.1023/a:1016281925554 · Cited by 77 · cited 1×
“12,17 The use of a pulmonary delivery method that mimics the methods used in clinical therapy may therefore be important for preclinical investigations of pulmonary drug absorption.”
Methods used to assess pulmonary deposition and absorption of drugs
Mobley, C., & Hochhaus, G. (2001) · Drug Discovery Today · doi:10.1016/s1359-6446(01)01691-9 · Cited by 72 · cited 1×
“23 In the IPL-model, lung-specific events can be investigated without the contribution of systemic absorption, distribution, and elimination of the drug.”
Byron, P. R., Roberts, S. R. N., & Clark, A. R. (1986) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600750214 · Cited by 61 · cited 1×
“27 In humans, a more uniform and peripheral lung deposition after inhalation at a slow flow rate, compared to fast rate inhalation, has been re-ported.”
Techniques for drug delivery to the airways, and the assessment of lung function in animal models
Raeburn, D., Underwood, S. L., & Villamil, M. E. (1992) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/1056-8719(92)90035-y · Cited by 55 · cited 2×
“8,9 Differences in pharmacokinetic profiles be-tween liquid instillation and aerosol administration has been reported.”
Peptide delivery via the pulmonary route: a valid approach for local and systemic delivery
Smith, P. L. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(96)01579-9 · Cited by 51
A novel dosing method for drug administration to the airways of the isolated perfused rat lung
Byron, P. R., & Niven, R. W. (1988) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600770810 · Cited by 42 · cited 2×
“34 Fluorocarbon propellant was used to expel the 100-m L liquid dose in a vapor volume of 6.1 mL.”
InfluentialFolkesson, H. G., Weström, B. R., Dahlbäck, M., Lundin, S., & Karlsson, B. W. (1992) · Experimental Lung Research · doi:10.3109/01902149209031697 · Cited by 37 · cited 2×
“10,11 To obtain reliable dosing the liquid must be carefully in-stilled in order not to cause airway obstruction, disturb the normal breathing pattern of the animal, or induce cough, which will lead to rapid clearance of part of the dose from the airways into the mouth and stomach.”
Aerosol Inhalation: Recent Research Frontiers
Marijnissen, J. C. M., Gradoń, L., & Phalen, R. F. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965430 · Cited by 33
Deposition and fate of aerosolized drugs
Newhouse, M. T., & Ruffin, R. E. (1978) · CHEST Journal · doi:10.1378/chest.73.6.936 · Cited by 24
Taljański, W., Pierzynowski, S. G., Lundin, P., Weström, B. R., Eirefelt, S., Podleśny, J., Dahlbäck, M., Siwińska-Gołebiowska, H., & Karlsson, B. W. (1997) · PubMed · Cited by 23
Jeppsson, A. ‐., Nilsson, E., & Waldeck, B. (1994) · European Journal of Pharmacology · doi:10.1016/0014-2999(94)90705-6 · Cited by 22
Effect of tidal volume and frequency on the temporal fall in lung compliance
Huang, Y. C., Weinmann, G. G., & Mitzner, W. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.5.2040 · Cited by 21
Evans blue dye modifies the ultrastructure of normal and regenerating arterial endothelium in rats
Jackiewicz, T. A., McGeachie, J. K., London, R. M., & Tennant, M. (1998) · Microsurgery · doi:10.1002/(sici)1098-2752(1998)18:1<47::aid-micr11>3.0.co;2-s · Cited by 12 · cited 1×
“32 Evans blue, 3 mg/mL, could not be used successfully for the distribution experiments in anesthetized rats.”
Effects of Systemic and Local Immunization on Alveolar Epithelial Permeability to Protein in the Rat
Folkesson, H. G., Weström, B. R., & Karlsson, B. W. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9703028 · Cited by 11
Intratracheal Catheters as Drug Delivery Systems
MacIntyre, N. R. (2001) · Respiratory Care · doi:10.1177/002013240104600210 · Cited by 10 · cited 1×
“18,19 The technique may facilitate dosing procedures in preclinical pulmonary drug delivery investigations since it is easy to use and does not require complex dosimetry.”
Svartengren, M., Skogward, P., Nerbrink, O., & Dahlbäck, M. (1998) · Experimental Lung Research · doi:10.3109/01902149809099580 · Cited by 7 · cited 1×
“9,31 However, in this study we found that Evans blue 10 mg/mL induced exudation in the airways of the isolated and perfused rat lung (observations during experiments).”
Selective aerosol delivery to intubated rats; a comparison with nose only exposure
Eirefelt, S., Nerbrink, O., & Dahlbäck, M. (1992) · Journal of Aerosol Science · doi:10.1016/0021-8502(92)90456-6 · Cited by 7 · cited 1×
“35 The system efficiently delivered 80% of the lung-deposited dose to the peripheral region of the lung.”
Drug uptake from the airways and lungs.
Widdicombe, J. (1998) · PubMed · Cited by 6
Aerosol Delivery to the Respiratory tract in Experimental Animals
Dahlbäck, M., Eirefelt, S., & Nerbrink, O. (1996) · Springer eBooks · doi:10.1007/978-94-009-1694-4_16 · Cited by 3 · cited 4×
“8,9 Differences in pharmacokinetic profiles be-tween liquid instillation and aerosol administration has been reported.”
Influential
Research works printed but not linked: 9
- 10.1002/(SICI)1096-9136(199701)14:1<63::AID-DIA298>3.3.CO;2-6 · doi:10.1002/(sici)1096-9136(199701)14:1<63::aid-dia298>3.3.co;2-6
- Brown R.A., 1983, Drug Metab. Dispos., 11, 355
- Widdicombe J., 1998, Indian J. Physiol. Pharmacol., 42, 3
- Schanker L.S., 1986, Drug Metab. Dispos., 14, 79
- Taljanski W., 1997, Drug Metab. Dispos., 25, 917
- MacIntyre N.R., 2001, Respir. Care, 46, 193
- Wixson S.K., 1987, Lab. Anim. Sci., 37, 736
- Newman S.P., 1982, Eur. J. Respir. Dis., 63, 57
- 10.1002/(SICI)1099-1263(199803/04)18:2<149::AID-JAT490>3.3.CO;2-C · doi:10.1002/(sici)1099-1263(199803/04)18:2<149::aid-jat490>3.3.co;2-c
Cited by
Sakagami, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.012 · Cited by 331
“〈LIQUID〉 Tracheotomy SYR-N 250 μl 75 ∼ 10 ARG 100 μl 55 ∼ 10 ARG 10 μl 25 ∼ 30 ARG Tracheotomy SYR 100 μl 67 15 [77] Tracheotomy CM-SPR 100 μl 91 5 [31] 20 μl 73 18 [32] Orotracheal SYR-N 100 μl 85 ∼ 4 ARG 10 μl 50 ∼ 18 ARG Orotracheal SYR-N 100 μl 92 ∼ 15 [73] Orotracheal CM-SPR 250 μl 62 NR [68] Orotracheal CM-SPR ∼…”
BackgroundMethodResultInfluentialFröhlich, E., & Salar-Behzadi, S. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15034795 · Cited by 249
“When coupled to a ventilator, a nebulization catheter can deliver a pulse-timed spray dosing delivery to the lung [95].”
MethodAerosol Delivery During Mechanical Ventilation: From Basic Techniques to New Devices
Dhand, R. (2008) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2007.0663 · Cited by 164
“The intracorporeal nebulizing catheter (Aeroprobe; Trudell Medical International, London, ON, Canada) is a novel device that produces an aerosol in the trachea.(64) A central lumen transmits the solution to be nebulized and compressed gas is forced under high pressure (100 psi) at a variable flow rate (0.”
Tronde, A., Nordén, B. O., Marchner, H., Wendel, A., Lennernäs, H., & Bengtsson, U. H. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10386 · Cited by 158
Ehrhardt, C., & Kim, K. (2007) · Springer eBooks · doi:10.1007/978-0-387-74901-3 · Cited by 183
Metadata
- Authors
- Tronde, A., Baran, G., Eirefelt, S., Lennernäs, H., & Bengtsson, U. H.
- Affiliations
- Uppsala University (SE)
- Trudell Medical International (Canada) (CA)
- AstraZeneca (Sweden) (SE)
- Venue
- Journal of Aerosol Medicine
- Publisher
- SAGE Publications
- Published
- 2002-09
- Volume
- 15
- Issue
- 3
- Pages
- 283-296
- ISSN
- 0894-2684 (ISSN-L)
- 1557-9026
- OpenAlex
- W2162724031
- Cited by
- 45
- References
- 38
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 4 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
- Locations
- Journal of Aerosol Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- AstraZeneca
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- aerosol drug delivery, pulmonary drug delivery, regional lung distribution, isolated perfused lung, droplet size distribution, rat lung, aerosol dosimetry
- MeSH terms
- Administration, Inhalation, Aerosols, Animals, Catheterization, Coloring Agents, Lung, Male, Miniaturization, Nebulizers and Vaporizers, Perfusion, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.