An Assessment of Covalent Grafting of RGD Peptides to the Surface of a Compliant Poly(Carbonate-Urea)Urethane Vascular Conduit versus Conventional Biological Coatings: Its Role in Enhancing Cellular Retention
The DOI matches its Crossref record.
Abstract
The aim of sodding prosthetic grafts with endothelial cells (EC) is to establish a functioning antithrombogenic monolayer of EC. Application of basement membrane proteins improves EC adherence on ePTFE grafts. Their addition to a biodurable compliant poly(carbonate-urea)urethane graft (CPU) was studied with respect to EC adherence. Preclot, fibronectin, gelatin, and collagen were coated onto CPU. RGD peptide, heparin, and both RGD and heparin were chemically bonded to CPU. Human umbilical vein EC (HUVEC) labeled with 111-Indium oxine were sodded (1.8 x 10(6) EC/cm(2)) onto native and the modified CPU. The grafts were washed after 90 min and EC retention determined. The experiments were repeated six times. EC retention on native CPU was 1.0 +/- 0.2 x 10(5) EC/cm(2). The application of preclot, fibronectin, gelatin, and collagen did not improve EC retention, which was 0.8 +/- 0.1, 0.4 +/- 0.1, 0.3 +/- 0.08, and 0.5 +/- 0.2 x 10(5) EC/cm(2), respectively. Bonding RGD, heparin, and both RGD and heparin significantly improved EC retention to 1.9 +/- 0.6, 1.7 +/- 0.5, and 2.6 +/- 0.6 x 10(5) EC/cm(2), respectively (p < 0.01). Bonding of RGD, heparin, and both RGD and heparin accelerates and enhances EC retention onto CPU. Simple coating of basement membrane proteins confers no advantage over native CPU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Kannan, R. Y., Salacinski, H. J., Sales, K., Butler, P., & Seifalian, A. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.006 · Cited by 373
Self-citationBiofunctionalization of Biomaterials for Accelerated in Situ Endothelialization: A Review
de Mel, A., Jell, G., Stevens, M. M., & Seifalian, A. M. (2008) · Biomacromolecules · doi:10.1021/bm800681k · Cited by 351
Self-citationCitric acid: A green cross-linker of biomaterials for biomedical applications
Salihu, R., Abd Razak, S. I., Ahmad Zawawi, N., Rafiq Abdul Kadir, M., Izzah Ismail, N., Jusoh, N., Riduan Mohamad, M., & Hasraf Mat Nayan, N. (2021) · European Polymer Journal · doi:10.1016/j.eurpolymj.2021.110271 · Cited by 193
Kidane, A. G., Salacinski, H., Tiwari, A., Bruckdorfer, K. R., & Seifalian, A. M. (2004) · Biomacromolecules · doi:10.1021/bm0344553 · Cited by 166
Self-citationRational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
Polymeric Materials for Tissue Engineering of Arterial Substitutes
Ravi, S., Qu, Z., & Chaikof, E. L. (2009) · Vascular · doi:10.2310/6670.2008.00084 · Cited by 91
“Endothelial attachment was significantly improved on surfaces coupled with another potent adhesion peptide, RGD, when compared with fibronectin-coated grafts.(26,27) Zilla and colleagues further improved cell retention on shear stressed grafts with precoated RGD-cross-linked fibrin.”
Metadata
- Authors
- Krijgsman, B., Seifalian, A. M., Salacinski, H. J., Tai, N. R., Punshon, G., Fuller, B. J., & Hamilton, G.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2002-08
- Volume
- 8
- Issue
- 4
- Pages
- 673-680
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2172567299
- Cited by
- 69
- References
- 0
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.