Engineering of Functional Tendon
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Surgical tendon repair is limited by the availability of viable tissue for transplantation. Because of its relatively avascular nature, tendon is a prime candidate for engineered tissue replacement. To address this problem, cells isolated from rat Achilles tendon were grown to confluence in culture and allowed to self-assemble into a cylinder between two anchor points. The resulting scaffold-free tissue was composed of aligned, small-diameter collagen fibrils, a large number of cells, and an excess of noncollagenous extracellular matrix; all characteristics of embryonic tendon. The stress-strain response of the constructs also resembles the nonlinear behavior of immature tendons, and the ultimate tensile strength is approximately equal to that of embryonic chick tendon, roughly 2 MPa. These physical and mechanical properties indicate that these constructs are the first viable tendons engineered in vitro, without the aid of artificial scaffolding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bell, E., Ivarsson, B., & Merrill, C. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.3.1274 · Cited by 2,067
Basic Biomechanics of the Musculoskeletal System
Nordin, E. B. M., & Frankel, V. H. (1989) · Medical Entomology and Zoology · Cited by 871
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Tendons and ligaments: A morphological and biochemical comparison
Amiel, D., Frank, C., Harwood, F., Fronek, J., & Akeson, W. (1983) · Journal of Orthopaedic Research · doi:10.1002/jor.1100010305 · Cited by 607
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Brown, R. A., Wiseman, M., Chuo, C. ‐., Cheema, U., & Nazhat, S. N. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200500042 · Cited by 480
Brown, R. A., Prajapati, R., McGrouther, D. A., Yannas, I. V., & Eastwood, M. (1998) · Journal of Cellular Physiology · doi:10.1002/(sici)1097-4652(199806)175:3<323::aid-jcp10>3.0.co;2-6 · Cited by 388
DENNIS, R. G., & KOSNIK, II (2000) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1290/1071-2690(2000)036<0327:eaicpo>2.0.co;2 · Cited by 370
Self-citationUltrastructure of the Connective Tissue Matrix
(1984) · Springer eBooks · doi:10.1007/978-1-4613-2831-5 · Cited by 255
Paralysis and growth of the musculoskeletal system in the embryonic chick
Hall, B. K., & Herring, S. W. (1990) · Journal of Morphology · doi:10.1002/jmor.1052060105 · Cited by 239
Cited by
Silk fibroin biomaterials for tissue regenerations
Kundu, B., Rajkhowa, R., Kundu, S. C., & Wang, X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.043 · Cited by 1,391
Stem cell-based tissue engineering with silk biomaterials
Wang, Y., Kim, H.-J., Vunjak-Novakovic, G., & Kaplan, D. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.008 · Cited by 968
Tendon: Biology, Biomechanics, Repair, Growth Factors, and Evolving Treatment Options
James, R., Kesturu, G., Balian, G., & Chhabra, A. B. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.09.007 · Cited by 568
Brown, R. A., Wiseman, M., Chuo, C. ‐., Cheema, U., & Nazhat, S. N. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200500042 · Cited by 480
A 3D bioprinted complex structure for engineering the muscle–tendon unit
Merceron, T. K., Burt, M., Seol, Y.-J., Kang, H.-W., Lee, S. J., Yoo, J. J., & Atala, A. (2015) · Biofabrication · doi:10.1088/1758-5090/7/3/035003 · Cited by 373
Sahoo, S., Toh, S. L., & Goh, J. C. H. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.004 · Cited by 329
Design and preparation of polymeric scaffolds for tissue engineering
Weigel, T., Schinkel, G., & Lendlein, A. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.835 · Cited by 228
Self-Organization and the Self-Assembling Process in Tissue Engineering
Athanasiou, K. A., Eswaramoorthy, R., Hadidi, P., & Hu, J. C. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152423 · Cited by 225
“…2010 (42), Zhang et al. 2011 (85), Nishida et al. 2004 (110) Tendon and ligament Self-organization Tangent modulus of 15 to 17 MPa Preclinical animal studies Calve et al. 2004 (33), Hairfield-Stein et al. 2007 (63), Huang et al. 2005 (64), Calve et al. 2010 (66) Liver Self-organization Albumin…”
Ligament regeneration using a knitted silk scaffold combined with collagen matrix
Chen, X., Qi, Y.-Y., Wang, L.-L., Yin, Z., Yin, G.-L., Zou, X.-H., & Ouyang, H.-W. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.017 · Cited by 212
“So far, no prosthetic devices, including Dacron grafts, carbon fibers, and silastic sheets, have been able to adequately restore the function for long term [8,9].”
BackgroundCo-electrospun dual scaffolding system with potential for muscle–tendon junction tissue engineering
Ladd, M. R., Lee, S. J., Stitzel, J. D., Atala, A., & Yoo, J. J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.038 · Cited by 212
Metadata
- Authors
- Calve, S., Dennis, R. G., Kosnik, P. E., Baar, K., Grosh, K., & Arruda, E. M.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2004-05
- Volume
- 10
- Issue
- 5-6
- Pages
- 755-761
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2068947407
- Cited by
- 167
- References
- 34
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.