CoChat

Design of Artificial Myocardial Microtissues

Kelm, Jens M., Ehler, Elisabeth, Nielsen, Lars K., Schlatter, Stefan, Perriard, Jean-Claude, Fussenegger, Martin · 2004 · Tissue Engineering
Cited by 127

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Cultivation technologies promoting organization of mammalian cells in three dimensions are essential for gene-function analyses as well as drug testing and represent the first step toward the design of tissue replacements and bioartificial organs. Embedded in a three-dimensional environment, cells are expected to develop tissue-like higher order intercellular structures (cell-cell contacts, extracellular matrix) that orchestrate cellular functions including proliferation, differentiation, apoptosis, and angiogenesis with unmatched quality. We have refined the hanging drop cultivation technology to pioneer beating heart microtissues derived from pure primary rat and mouse cardiomyocyte cultures as well as mixed populations reflecting the cell type composition of rodent hearts. Phenotypic characterization combined with detailed analysis of muscle-specific cell traits, extracellular matrix components, as well as endogenous vascular endothelial growth factor (VEGF) expression profiles of heart microtissues revealed (1). a linear cell number-microtissue size correlation, (2). intermicrotissue superstructures, (3). retention of key cardiomyocyte-specific cell qualities, (4). a sophisticated extracellular matrix, and (5). a high degree of self-organization exemplified by the tendency of muscle structures to assemble at the periphery of these myocardial spheroids. Furthermore (6). myocardial spheroids support endogenous VEGF expression in a size-dependent manner that will likely promote vascularization of heart microtissues produced from defined cell mixtures as well as support connection to the host vascular system after implantation. As cardiomyocytes are known to be refractory to current transfection technologies we have designed lentivirus-based transduction strategies to lead the way for genetic engineering of myocardial microtissues in a clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/107632704322791853

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 127

Metadata

Authors
Kelm, J. M., Ehler, E., Nielsen, L. K., Schlatter, S., Perriard, J.-C., & Fussenegger, M.
Venue
Tissue Engineering
Published
2004-01
Volume
10
Issue
1-2
Pages
201-214
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W1974159415
Cited by
127
References
4
FWCI
7.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of Artificial Myocardial Microtissues. https://app.cochat.ai/papers/10.1089/107632704322791853
The paper
Kelm, J. M., Ehler, E., Nielsen, L. K., Schlatter, S., Perriard, J.-C., & Fussenegger, M. (2004). Design of Artificial Myocardial Microtissues. Tissue Engineering. https://doi.org/10.1089/107632704322791853

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.